Stability behavior of the transmission line system under incremental dynamic wind load

  • Sarmasti, Hadi;Abedi, Karim;Chenaghlou, Mohammad Reza
    • Wind and Structures
    • /
    • 제31권6호
    • /
    • pp.509-522
    • /
    • 2020
  • Wind load is the principal cause for a large number of the collapse of transmission lines around the world. The transmission line is traditionally designed for wind load according to a linear equivalent method, in which dynamic effects of wind are not appropriately included. Therefore, in the present study, incremental dynamic analysis is utilized to investigate the stability behavior of a 400 kV transmission line under wind load. In that case, the effects of vibration of cables and aerodynamic damping of cables were considered on the stability behavior of the transmission line. Superposition of the harmonic waves method was used to calculate the wind load. The corresponding wind speed to the beginning of the transmission line collapse was determined by incremental dynamic analysis. Also, the effect of the yawed wind was studied to determine the critical attack angle by the incremental dynamic method. The results show the collapse mechanisms of the transmission line and the maximum supportable wind speed, which is predicted 6m/s less than the design wind speed of the studied transmission line. Based on the numerical modeling results, a retrofitting method has been proposed to prevent failure of the tower members under design wind speed.

6도체방식 송전선로의 서브스판진동 해석에 관한 연구 (A study on Subspan Oscillation Analysis of 6 Bundle Conductor Transmission lines)

  • 이형권
    • 소음진동
    • /
    • 제7권5호
    • /
    • pp.729-736
    • /
    • 1997
  • The subspan oscillation is the most important in bundled transmission lines, which can cause conductor damage and transmission line hardware failures. So it is necessary to analyze the subspan oscillation in details for transmission lines. This paper suggests the basic concept and theoretical analysis method of subspan oscillation for 6 bundle conductor transmission line, which considers wind speed, subspan length and conductor tension. Especially this paper uses a spacer damper model with clamp-arm flexibility and damping characteristics. Theoretical analysis results are proposed.

  • PDF

345kV 인천화력 송전선로 철탑도괴 원인분석 및 대책 (345kV Overhead Transmission Line Collapse Analysis and Countermeasures)

  • 박재웅;신태우;최진성;최한열;민병욱
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.531-535
    • /
    • 2010
  • 345kV Incheon Thermal Power Plant Transmission Line Collapse Analysis and Countermeasures. The Typhoon Galmaegi which had been formed in July 15, 2008 diminished into a tropical cyclone and cooled the air above the West Sea. The cooled air colliding with the warm inland air caused a strong whirlwind at some places in the west seaside; the whirlwind battered the 345kV Incheon Thermal Power Plant Transmission Line to be collapsed. The resistance of transmission towers against wind pressure, one of the key elements in transmission line engineering, is designed to endure the pressure corresponding to the maximum instantaneous wind speed. Before the above accident happened, no transmission line has ever been collapsed by a whirlwind. So this paper is aimed to analyze causes that collapsed 345kV Incheon Thermal Power Plant transmission line and to introduce countermeasures.

On the Limitation of Telegrapher′s Equations for Analysis of Nonuniform Transmission Lines

  • Kim, Se-Yun
    • Journal of electromagnetic engineering and science
    • /
    • 제4권2호
    • /
    • pp.68-71
    • /
    • 2004
  • The limitation of telegrapher's equations for analysis of nonuniform transmission lines is investigated here. It is shown theoretically that the input impedance of a nonuniform transmission line cannot be derived uniquely from the Riccati equation only except for the exponential transmission line of a particular frequency-dependent taper. As an example, the input impedance of an angled two-plate transmission line is calculated by solving the telegrapher's equations numerically. The numerical results suffer from larger deviation from its rigorous solution as the plate angle increases.

A Coupled-Field Analysis of Galloping for Power Transmission Line

  • Kim, Hwan-Seong;Nguyen, Tuong-Long;Byun, Gi-Sig
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.74.3-74
    • /
    • 2002
  • . A Coupled-Field Analysis of Galloping for Power Transmission Line . Fluid-Structure interaction, Galloping, Power Transmission Line, ANSYS

  • PDF

재무적 송전권의 전력시장에의 영향 분석 (Analysis of the Competitive Effects of Financial Transmission Rights on Electricity Markets)

  • 김진호;박종배;신중린
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권6호
    • /
    • pp.350-357
    • /
    • 2004
  • In a deregulated electricity generation market, the sufficient capacity of transmission lines will promote the competition among generation companies (Gencos). In this paper, we show that Gencos' possession of rights to collect congestion rents may increase the competition effects of the transmission lines. In order for concrete analysis on this effect, a simple symmetric market model is introduced. In this framework, introducing the transmission right to the Gencos has the same strategic effects as increasing the line capacity of the transmission line. Moreover, the amount of effectively increased line capacity is equal to the amount of the line rights. We also show that the asymmetric share of the financial transmission rights may result in an asymmetric equilibrium even for symmetric firms and markets. We also demonstrate these aspects in equal line rights model and single firm line rights model. Finally, a numerical example is provided to show the basic idea of the proposed paper.

송전선에 의해 송전철탑에 전달되는 풍하중 저감을 위한 회전형 점탄성감쇠기 (Rotational Viscoelastic Dampers for the Mitigation of Wind Loads on Transmission Tower Transferred from Transmission Lines)

  • 문병욱;민경원
    • 한국소음진동공학회논문집
    • /
    • 제16권4호
    • /
    • pp.420-427
    • /
    • 2006
  • In this study, wind loads transmitted to a transmission tower from transmission lines are mitigated using rotational viscoelastic dampers. First, the wind load characteristics in a transmission tower is investigated considering the effect of the transmission lines through stochastic analysis. The assemblage of the transmission line and insulator are modeled as a double pendulum system connected to the SDOF model of the tower. From the result of the stochastic analysis, the background component of the overturing moment caused by the wind loads acting on the transmission lines are found to have considerable portion in the total overturning moment. Based on this observation result, a strategy Installing rotational viscoelastic damper (VED) between tower arm and transmission line is proposed for the mitigation of the transmission line reactions, which play a role as dynamic loads on a transmission tower. For the purpose of verification, time history analysis is conducted for different wind velocities and VED parameters. The analysis result shows that the rotational VED is effective for the mitigation of the background component rather than the resonance component of the transmission line reactions and achieves the reduction ratio of 50% even for higher wind speed.

점탄성감쇠기를 이용한 송전철탑 풍하중의 저감 (Wind Load Mitigation for Transmission Tower using Viscoelastic Damper)

  • 민경원;박지훈;문병욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.955-958
    • /
    • 2005
  • In this study, the wind load characteristics for a transmission tower is investigated considering the effect of the transmission lines through stochastic analysis. The assemblage of the transmission line and insulator are modeled as a double pendulum system connected to the SDOF model of the tower It is observed that the background component of the overturing moment induced by the wind response of the transmission line has considerable portion in the total overturning moment. Based on this result, a rotational viscoelastic damper (VED) is proposed for the mitigation of the transmission line reactions, which act as wind load transferred to the tower. To verify the effectiveness of the proposed strategy, time history analysis is conducted for different wind velocities and VED damping constants. From the analysis, the proposed VED is proved to be effective for mitigation of the background component rather than the resonance component of the transmission line reaction.

  • PDF

가선작업 하중을 고려한 765kV 강관철탑 설계 (765kV Steel Tubular Tower Design On Considering Stringing Load)

  • 정태호;김신철;윤영순;신태우;이안근;김광열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.935-937
    • /
    • 1998
  • The stringing load was added to tower design that consider the active load in 765kV transmission line construction. The nominal auxiliary members of steell tubular tower arm were altered into stress members by means of three dimensional design analysis method. 765kV transmission line construction also use self-standing tower that does not install temporary wire which support the section tower placed between drum field and engine field when stringing process.

  • PDF

345kV 혼합송전선로에서 재폐로가 절연설계에 미치는 영향 (Effects of Reclosing for Insulation Coordination in 345kV Combined Transmission Lines)

  • 이종범;정채균;임광식;강지원
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.847-853
    • /
    • 2010
  • This paper describes switching surge analysis for reclosing decision in 345kV combined transmission line with XLPE power cable. Reclosing operation should be decided based on the detailed technical analysis in combined transmission line because this line includes power cable section which is week on insulation. Insulation of power cable can be breakdown at the week point in case of reclosing moment. Therefore the detailed analysis has to be carried out by considering several conditions such as length ratio of power cable section, arrestor, inserting resistance, charging rate, grounding resistance, etc.. On the other hand sheath voltage on IJ(Insulated Joint) is analyzed to check dangerous condition on cable cover. Analysis is performed by EMTP/ATP. Analysis results show that reclosing can be operated as the single line-to-ground fault occurs on overhead line in 345kV combined transmission line, if the inserting resistance is considered before the operation of main circuit breaker.