• 제목/요약/키워드: Transmission dose

검색결과 218건 처리시간 0.029초

Effects of electron beam irradiation on the superconducting properties of YBCO thin films

  • Lee, Y.J.;Choi, J.H.;Jun, B.H.;Joo, J.;Kim, C.S.;Kim, C.J.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권4호
    • /
    • pp.15-20
    • /
    • 2016
  • The effects of electron beam (EB) irradiation on the superconducting critical temperature ($T_c$) and critical current density ($J_c$) of YBCO films were studied. The YBCO thin films were irradiated using a KAERI EB accelerator with an energy of 0.2 MeV and a dose of $10^{15}-10^{16}e/cm^2$. A small $T_c$ decrease and a broad superconducting transition were observed as the EB dose increased. The value of $J_cs$ (at 20 K, 50 K and 70 K) increased at doses of $7.5{\times}10^{15}$ and $2.2{\times}10^{16}e/cm^2$. However, $J_cs$ decreased as the dose increased further. The X-ray diffraction (XRD) analysis showed that the c axis of YBCO was elongated and the full width at half maximum (FWHM) increased as the dose increased, which is strong evidence of the atomic displacement by EB irradiation. The transmission electron microscopy (TEM) showed that the amorphous layer formed in the vicinity of the surfaces of the irradiated films. The amorphous phase was often present as an isolated form in the interior of the films. In addition to the formation of the amorphous phase, many striations running along the a-b direction of YBCO were observed. The high magnification lattice image showed that the striations were stacking faults. The enhancement of $J_c$ by EB irradiation is likely to be due to the lattice distortion and the formation of defects such as vacancies and stacking faults. The decrease in $J_c$ at a high EB dose is attributed to the extension of the amorphous region of a non-superconducting phase.

Spinal Cord Partial Block Technique Using Dynamic MLC

  • Cho, Sam-Ju;Yi, Byong-Yong;Back, Geum-Mun;Lee, Sang wook;Ahn, Seung-Do;Kim, Jong-Hoon;Kwon, Soo-Il;Park, Eun-Kyung
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.138-140
    • /
    • 2002
  • The spinal cord dose is the one of the limiting factor for the radiation treatment of the head & neck (H&N) or the thorax region. Due to the fact that the cord is the elongated shaped structure, it is not an easy task to maintain the cord dose within the clinically acceptable dose range. To overcome this problem, the spinal cord partial block technique (PBT) with the dynamic Multi-Leaf Collimator (dMLC) has been developed. Three dimension (3D) conformal beam directions, which minimize the coverage of the normal organs such as the lung and the parotid gland, were chosen. The PBT field shape for each field was designed to shield the spinal cord with the dMLC. The transmission factors were determined by the forward calculation method. The plan comparisons between the conventional 3D conformal therapy plan and the PTB plan were performed to evaluate the validity of this technique. The conformity index (CI) and the dose volume histogram (DVH) were used as the plan comparison indices. A series of quality assurance (QA) was performed to guarantee the reliable treatment. The QA consisted of the film dosimetry for the verification of the dose distribution and the point measurements. The PBT plan always generated better results than the conventional 3D conformal plan. The PBT was proved to be useful for the H&N and thorax region.

  • PDF

A Monitor Unit Verification Calculation in IMRT as a Dosimetry QA

  • Kung, J.H.;Chen, G.T.Y.;Kuchnir, F.T.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.68-73
    • /
    • 2002
  • In standard teletherapy, a treatment plan is generated with the aid of a treatment planning system, but it is common to perform an independent monitor unit verification calculation (MUVC). In exact analogy, we propose and demonstrate that a simple and accurate MUVC in Intensity Modulated Radiotherapy (IMRT) is possible. We introduce a concept of Modified Clarkson Integration (MCI). In MCI, we exploit the rotational symmetry of scattering to simplify the dose calculation. For dose calculation along a central axis (CAX), we first replace the incident IMRT fluence by an azimuthally averaged fluence. Second, the Clarkson Integration is carried over annular sectors instead of over pie sectors. We wrote a computer code, implementing the MCI technique, in order to perform a MUVC for IMRT purposes. We applied the code to IMRT plans generated by CORVUS. The input to the code consists of CORVUS plan data (e.g., DMLC files, jaw settings, MU for each IMRT field, depth to isocenter for each IMRT field), and the output is dose contribution by individual IMRT field to the isocenter. The code uses measured beam data for Sc, Sp, TPR, (D/Mu)$\_$ref/ and includes effects from MLC transmission, and radiation field offset. On a 266 MHZ desktop computer, the code takes less than 15 sec to calculate a dose. The doses calculated with MCI algorithm agreed within +/- 3% with the doses calculated by CORVUS, which uses a 1cm x 1cm pencil beam in dose calculation. In the present version of MCI, skin contour variations and inhomogeneities were neglected.

  • PDF

동일 기종 선형가속기간 8 MV 광자선에 대한 빔 매칭 정확도 평가 (Evaluation of Beam-Matching Accuracy for 8 MV Photon Beam between the Same Model Linear Accelerator)

  • 김연래;정진범;강성희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권2호
    • /
    • pp.105-114
    • /
    • 2020
  • This study aimed to assess of beam-matching accuracy for an 8 MV beam between the same model linear accelerators(Linac) commissioned over two years. Two models were got the customer acceptance procedure(CAP) criteria. For commissioning data for beam-matched linacs, the percentage depth doses(PDDs), beam profiles, output factors, multi-leaf collimator(MLC) leaf transmission factors, and the dosimetric leaf gap(DLG) were compared. In addition, the accuracy of beam matching was verified at phantom and patient levels. At phantom level, the point doses specified in TG-53 and TG-119 were compared to evaluate the accuracy of beam modelling. At patient level, the dose volume histogram(DVH) parameters and the delivery accuracy are evaluated on volumetric modulated arc therapy(VMAT) plan for 40 patients that included 20 lung and 20 brain cases. Ionization depth curve and dose profiles obtained in CAP showed a good level for beam matching between both Linacs. The variations in commissioning beam data, such as PDDs, beam profiles, output factors, TF, and DLG were all less than 1%. For the treatment plans of brain tumor and lung cancer, the average and maximum differences in evaluated DVH parameters for the planning target volume(PTV) and the organs at risk(OARs) were within 0.30% and 1.30%. Furthermore, all gamma passing rates for both beam-matched Linacs were higher than 98% for the 2%/2 mm criteria and 99% for the 2%/3 mm criteria. The overall variations in the beam data, as well as tests at phantom and patient levels remains all within the tolerance (1% difference) of clinical acceptability between beam-matched Linacs. Thus, we found an excellent dosimetric agreement to 8 MV beam characteristics for the same model Linacs.

흰쥐의 술 후 통증 모델에서 T형 칼슘 통로 차단제인 Ethosuximide와 Mibefradil의 항통각과민 효과 (Antihyperalgesic Effects of Ethosuximide and Mibefradil, T-type Voltage Activated Calcium Channel Blockers, in a Rat Model of Postoperative Pain)

  • 신혜란;차영덕;한정욱;윤정원;김부성;송장호
    • The Korean Journal of Pain
    • /
    • 제20권2호
    • /
    • pp.92-99
    • /
    • 2007
  • Background: A correlation between a T-type voltage activated calcium channel (VACC) and pain mechanism has not yet been established. The purpose of this study is to find out the effect of ethosuximide and mibefradil, representative selective T-type VACC blockers on postoperative pain using an incisional pain model of rats. Methods: After performing a plantar incision, rats were stabilized on plastic mesh for 2 hours. Then, the rats were injected with ethosuximide or mibefradil, intraperitoneally and intrathecally. The level of withdrawal threshold to the von Frey filament near the incision site was determined and the dose response curves were obtained. Results: After an intraperitoneal ethosuximide or mibefradil injection, the dose-response curve showed a dose-dependent increase of the threshold in a withdrawal reaction. After an intrathecal injection of ethosuximide, the threshold of a withdrawal reaction to mechanical stimulation increased and the increase was dose-dependent. After an intrathecal injection of mibefradil, no change occurred in either the threshold of a withdrawal reaction to mechanical stimulation or a dose-response curve. Conclusions: The T-type VACC blockers in a rat model of postoperative pain showed the antihyperalgesic effect. This effect might be due to blockade of T-type VACC, which was distributed in the peripheral nociceptors or at the supraspinal level. Further studies of the effect of T-type VACC on a pain transmission mechanism at the spinal cord level would be needed.

고 투과 C 형 개구를 이용한 나노 크기 패턴 구현 (Nano-size Patterning with a High Transmission C-shaped Aperture)

  • 박신증;김용우;이응만;한재원
    • 한국정밀공학회지
    • /
    • 제24권11호
    • /
    • pp.108-115
    • /
    • 2007
  • We have designed a high transmission C-shaped aperture using finite differential time domain (FDTD) technique. The C-shaped aperture was fabricated in the aluminum thin film on a glass substrate using a focused ion beam (FIB) milling. Nano-size patterning was demonstrated with a vacuum contact device to keep tight contact between the Al mask and the photoresist. Using 405 nm laser, we recorded a 50 nm-size dot pattern on the photoresist with the aperture and analyzed the spot size dependent on the dose illuminated on the aperture.

Trial of Computer Simulation of Image Reconstruction from Incomplete Data for New CT with Reduced Exposure

  • Hayakawa, Yoshinori;Furuya, Toshimitsu;Sakakibara, Norifumi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.382-384
    • /
    • 2002
  • Filtered-Back-Projection technique is used in X-ray CT image reconstruction. This requires X-ray transmission data from all directions. As the transverse cross-section of the body is approximately 50 cm, transmitted X-rays in this direction are strongly attenuated. If X-ray transmission data in this direction is avoided, exposure to the patients seems to be reduced one 20th of usual value. Some alternative method has to be found for clinically sufficient image quality. New methods are under development and tentative results are reported that utilizes the principle of superposition.

  • PDF

Partial transmission block 제작 시 real block과 MLC를 이용한 방법 중 효율적인 방법에 대한 고찰 (Partial transmission block production for real efficient method of block and MLC)

  • 최지민;박주영;주상규;안종호
    • 대한방사선치료학회지
    • /
    • 제16권2호
    • /
    • pp.19-24
    • /
    • 2004
  • 목적 : Pelvis내에 존재하는 large lesion과 inguinal lymph node를 동시에 치료하고자 할때 femoral head에 과도한 선량을 피할 목적으로 partial transmission block(이하PTB)이 사용되어져 왔다. 그러나 field가 서로 overlap되거나 분리되는 문제를 해결하기 위한 다소 복잡하고 시간도 많이 걸리는 어려움이 있어 본 논문에서는 real block과 MLC를 이용하여 각각 PTB를 제작한 후 몇 가지 비교를 통하여 두 가지 중 실제 임상에 더 효율적으로 사용할 수 있는 방법을 연구하였다. 대상 및 방법 : 실제 치료 환자를 대상으로 디자인 된 PTB를 real block과 MLC를 이용하여 각각 제작한 뒤 아크릴 phantom으로 환자의 두께를 재현하고 치료 시와 동일한 조건으로 노광된 film을 획득하였다. field간에 overlap되는 부분과 분리되는 부분은 block을 미세 조장한 후 다시 촬영하였으며 오차가 1mm이내에 들어 올때까지 junction을 반복 tuning하였다. 두 block을 재현성, 제작 편의성, 제작 시간으로 나누어 비료 분석하였다. 재현성은 5회 반복 측정을 실시하였으며, 제작 편의성 및 제작 시간은 real block과 MLC가 각각 제작 시작 시간부터 완성되는 시점까지에 대하여 측정하였다. 결과 : PTB를 제작함에 있어서 real block과 MLC는 재현성 면에서는 유의할 만한 차이를 보이지 않았다. 그러나 제작 편의성에 있어서는 MLC가 junction tuning을 더 간편하게 수행 할 수 있었으며, 제작 시간 면에 있어서도 MLC가 real block에 비해 약$33\%$정도의 시간 절감 효과가 있음을 알 수 있었다. 결론 : PTB를 제작함에 있어서 real block과 MLC를 이용하는 것이 각각 장단점을 가지고 있으나 real block은 제작 편의성면에서 유연서이 떨어짐으로 각 fie의 junction을 tuning하는데 매우 어려움이 따름과 동시에 비교적 정확한 junction tuning을 시행할 수 있음을 알수 있었다. MLC특성상 발생되는 계단형태의 junction을 보완하여 PTB를 제작한다면 실제 임상에서 훨씬 간편하고 효율성 있는 업무를 수행할 수 있을 것으로 사료된다.

  • PDF

휠로더 자동변속기의 변속품질 평가 방법에 관한 연구 (A Study on the Quantitative Assessment Method for Shift Quality of Automatic Transmission in a Wheel Loader)

  • 이종찬;김관수;임종형;이효원;권영민;김형준;이민희
    • 대한기계학회논문집A
    • /
    • 제32권7호
    • /
    • pp.561-568
    • /
    • 2008
  • The quality of the automatic transmission shift for a wheel loader has been generally evaluated by driver's perception. However the subjective evaluation of the drivers is not always directly related to the shift quality. It is necessary to set up the method for an objective assessment of the shift quality. In this paper, a quantitative assessment method has been developed for the shift quality of the automatic transmission in a wheel loader. The indices for the evaluation were selected through the various tests like the acceleration and the turbine rpm as well as the subjective evaluation of the driver, and were validated by the correlation between subjective and objective assessments using a psychophysical power law. Based on this method, the shift quality of a wheel loader has been evaluated quantitatively under various shift conditions.

스플라인 정칙자를 사용한 투과 단층촬영을 위한 벌점우도 영상재구성 (Penalized-Likelihood Image Reconstruction for Transmission Tomography Using Spline Regularizers)

  • 정지은;이수진
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권5호
    • /
    • pp.211-220
    • /
    • 2015
  • Recently, model-based iterative reconstruction (MBIR) has played an important role in transmission tomography by significantly improving the quality of reconstructed images for low-dose scans. MBIR is based on the penalized-likelihood (PL) approach, where the penalty term (also known as the regularizer) stabilizes the unstable likelihood term, thereby suppressing the noise. In this work we further improve MBIR by using a more expressive regularizer which can restore the underlying image more accurately. Here we used a spline regularizer derived from a linear combination of the two-dimensional splines with first- and second-order spatial derivatives and applied it to a non-quadratic convex penalty function. To derive a PL algorithm with the spline regularizer, we used a separable paraboloidal surrogates algorithm for convex optimization. The experimental results demonstrate that our regularization method improves reconstruction accuracy in terms of both regional percentage error and contrast recovery coefficient by restoring smooth edges as well as sharp edges more accurately.