• Title/Summary/Keyword: Transmission control

Search Result 4,097, Processing Time 0.029 seconds

Development of an operation and control software for electro-hydraulic (전자유압식 CVT의 운용 및 제어 소프트웨어 개발과 실시간 제어)

  • Kwan, H. B.;Kim, K. W.;Kim, H. S.;Eun, T.;Park, C. I
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.36-46
    • /
    • 1993
  • In CVT vehicle, the engine speed is completely decoupled from the vehicle speed within the range from maximum transmission ratio to minimum transmission ratio. This allows the engine to operate in optimal state(e.g. best fuel economy or maximum power mode.) In this study, the CVT control algorithm for optimal operation of engine is suggested. In order to implement the real time digital control of electro-hydraulic CVT system, a software called CVTCON has been developed. CVTCON also includes the CVT operation module, (2) system test module, (3) system control module and (4) data management module. By using the CVTCON and the electro-hydraulic CVT system, two modes of experiments were carried out: constant throttle opening mode and acceleration mode. From the experimental result, it was found that the algorithm suggested in this study showed optimal operation of the CVT system.

  • PDF

Analysis of Hydraulic Control System for Shuttle Power-shift Transmission (전후진 파워시프트 변속기 유압 제어 시스템 해석)

  • Kim, D.C.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.4
    • /
    • pp.16-23
    • /
    • 2009
  • The major system of an agricultural shuttle power-shift tractor is the transmission, using power-shift. Because the shifting performance depends on the hydraulic control system, the most important aspect of the optimization is the design of the hydraulic control system. This study was conducted to develop the simulation model of hydraulic control system for the shuttle power-shift transmission by using Easy5 software. Bench test was conducted to verify the simulation. Also, the design parameters which influence the pressure modulation characteristics were investigated.

  • PDF

Wireless Networked Control Systems Using IEEE 802.15.4 (IEEE 802.15.4기반의 제어용 무선 네트워크에 대한 연구)

  • Lee, Jung-Il;Choi, Dong-Hyuk;Kim, Dong-Sung
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2006.11a
    • /
    • pp.289-292
    • /
    • 2006
  • In this paper, a wireless control network based on IEEE 802.15.4 MAC protocol is proposed. The superframe of IEEE 802.15.4 is applied to the proposed wireless control network. The transmission and bandwidth management method are proposed for efficient transmission in the superframe. By these methods, the proposed wireless control network protocol is able to transmit three types of data (periodic data, sporadic data, and non real-time message), and guarantee real-time transmission within deadline.

  • PDF

A Study on Applying the Direct Control Method for Small Forklift Transmission System (직접 제어 방식을 적용한 소형 지게차 변속 시스템에 관한 연구)

  • Jeong, Y.M.;Lim, K.;Yang, S.Y.
    • Journal of Drive and Control
    • /
    • v.10 no.4
    • /
    • pp.34-40
    • /
    • 2013
  • The transmission control method of small forklift is classified into pilot control method and direct control method. In pilot control method, the hydraulic circuit which consists a lot of components is very complex so the production process is too costly and time consuming. The direct control method contains fewer components that can be configured to simple hydraulic circuit. It has more advantages because the shift sensitivity of transmission is changed easily via the input profile. In this paper, the controller design and the input profile for system are studied to apply to the direct control method. The input profile consists of Fill section, Hold section and Ramp section. The characteristic of each section is obtained through experiment. As the result, the shift sensitivity and starting performance are effected by Fill section and Hold section.

A study on embedded & wireless fault code transmission device development for railroad vehicle (철도차량용 임베디드 무선전송장치의 개발에 관한 연구)

  • Kim, Jong-Keol;Shim, Ja-Hyun;Shon, Kang-Ho
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1255-1261
    • /
    • 2010
  • An operating information and fault recode of train is very important information for safety driving and maintenance. And these information is increased and need high speed as the number of trains is increased. Wireless LAN or CDMA network is efficient to report more complicated and various information from vehicle to server in control center. Existing wireless transmission system has weakness due to transmission system is separated with TDCS and standalone. At first, standalone system needs space to be installed and cost is increased. And data transmission capacity and speed is limited by complicated structure that transmission system receive data thru serial communication like RS232 and then data transmission system send data to server in control center. This article is study to develop embedded & wireless fault code transmission device to be installed in TDCS to overcome weakness of space and to have more cost effective and simple structure. It is adapted 802.11b/g WiFi for wireless communication and OS is used embedded Linux that can easily implement wireless communication environment and ensure TCP/IP communication’s security. We also implement simple server to test wireless communication between embedded & wireless fault code transmission device and server in control center.

  • PDF

Synchronized Transmission for Real-Time Remote Control in the Wireless Network (무선 네트워크에서 실시간 원격제어를 위한 동기화 전송)

  • Kang, Hongku;Kim, Namgon;Kim, Jong-Won
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.64-70
    • /
    • 2021
  • Nowadays, there are significant interests in real-time remote control using wireless networks. In implementing real-time remote control, one important factor is delay performance of real-time control message. Especially, the technique to reduce jitter of delay is necessary in transmitting periodically real-time control message. In this paper, we proposed synchronized transmission to reduce jitter of delay, when real-time control message was transmitted through wireless networks. The proposed transmission kept synchronization between source node and wireless transmitter and controlled transmission instance to transmit real-tie control message with fixed delay in wireless networks. According to results of experiment in military unmanned vehicle system, the proposed transmission reduced jitter of delay as 32% as that of a non-employing case.

Hypoxia-Inducible Factor-1 Alpha Stabilization in Human Macrophages during Leishmania major Infection Is Impaired by Parasite Virulence

  • Ben-Cheikh, Ali;Bali, Aymen;Guerfali, Fatma Z;Atri, Chiraz;Attia, Hanene;Laouini, Dhafer
    • Parasites, Hosts and Diseases
    • /
    • v.60 no.5
    • /
    • pp.317-325
    • /
    • 2022
  • Hypoxia-inducible factor-1 alpha (HIF-1α) is one of the master regulators of immune and metabolic cellular functions. HIF-1α, a transcriptional factor whose activity is closely related to oxygen levels, is a target for understanding infectious disease control. Several studies have demonstrated that HIF-1α plays an important role during the infectious process, while its role in relation to parasite virulence has not been addressed. In this work, we studied the expression levels of HIF-1α and related angiogenic vascular endothelial growth factor A (VEGF-A) in human macrophages infected with promastigotes of hypo- or hyper-virulent Leishmania major human isolates. L. major parasites readily subverted host macrophage functions for their survival and induced local oxygen consumption at the site of infection. In contrast to hypo-virulent parasites that induce high HIF-1α expression levels, hyper-virulent L. major reduced HIF-1α expression in macrophages under normoxic or hypoxic conditions, and consequently impeded the expression of VEGF-A mRNA. HIF-1α may play a key role during control of disease chronicity, severity, or outcome.

Real-time data transmission through congestion control based on optimal AQM in high-speed network environment (고속 네트워크 환경에서 최적AQM기반의 혼잡제어를 통한 실시간 데이터 전송)

  • Hwang, Seong-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.7
    • /
    • pp.923-929
    • /
    • 2021
  • TCP communication and packet communication require transmission control technology to ensure high quality and high reliability. However, in the case of real-time data transmission, an inefficient transmission problem occurs. In order to overcome this problem and transmit the packet reliability, in general, early congestion control using the buffer level as an index was used. Control of the congestion control point and the cancellation point is delayed because the point at which congestion is controlled is based on the buffer level. Therefore, in this paper, not only the buffer level indicator, but also the ideal buffer level, which determines the packet discard probability, is classified so that the transmission rate and buffer level that measure network congestion are close to the level above the optimal setting. As a result, it was shown that the average buffer level can be directly controlled by maintaining the average buffer level by the ideal buffer level set in the experiment to prove the proposed method.

Minimum Energy Control of an S-CVT Equipped Power Transmission

  • Kim, Jungyun
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.82-91
    • /
    • 2004
  • This article deals with a minimum energy control law of S-CVT connected to a dc motor. The S-CVT can smoothly transit between the forward, neutral, and reverse states without any brakes or clutches, and its compact and simple design and its relatively simple control make it particularly effective for mechanical systems in which excessively large torques are not required. And such an S-CVT equipped power transmission has the advantage of being able to operate the power sources in their regions of maximum efficiency, thereby improving the energy efficiency of the transmission system. The S-CVT was intended to primarily for use in small power capacity transmissions, thus a dc motor was considered here as the power source. We first review the structure and operating principles of the S-CVT, including experimental results of its performance. And then we describe a minimum energy control law of S-CVT connected to a do motor. To do this, we describe the results of an analysis of the dynamics of an S-CVT equipped power transmission and the power efficiency of a DC motor. The minimum energy control design is carried out via B-spline parameterization. And we show numerical results obtained from simulations illustrate the validity of our minimum energy control design, benchmarked with a computed torque control algorithm for S-CVT.

Design and Implementation of the Remote Image Transmission System using CDMA Communication Network (CDMA 통신망을 이용한 원격 영상 전송 시스템의 설계 및 구현)

  • 박성욱;황수철;박종욱
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.7 no.3
    • /
    • pp.54-61
    • /
    • 2002
  • A remote image transmission apparatus combines robot technology and image transmission there is safe problem or place that a person can not go. Recently, control apparatus that use wire and RF between web server and robot for remote control are developed. But there is problem that must install internet line and communication distance. Transmission distance problem call solve when using the equipment of RF, but price of RF router is problem that is very high cost. In this paper, we developed remote control system using the CDMA cellular phone communication network that can control image transmission and image transmission apparatus to solve these problem. Developed system could solve defects of methods that use existent RF and internet. And could transmit the most suitable image and voice under limited condition include current communication network.

  • PDF