• Title/Summary/Keyword: Transmission Zero

Search Result 330, Processing Time 0.025 seconds

A Study on the Algorithm for Fault Discrimination and Location in Underground Transmission Lines Using Travelling Wave and Wavelet Transform (Wavelet 변환 기반 진행파를 이용한 지중송전선로 고장종류 판별 및 고장점 추정에 관한 연구)

  • Park, Jae-Hong;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.350-352
    • /
    • 2005
  • Recently, electrical demands increase rapidly in metropolitan areas according to the extension of urban areas. Therefore underground transmission lines are getting expanded. This paper presents the rapid and accurate algorithm for fault discrimination and fault location in underground transmission lines. This paper uses fuzzy logic method using voltage and zero sequence for fault discrimination. And this paper uses travelling wave and wavelet transform for fault location. To prove the performance of the algorithm, it test algorithm with signal obtained from ATPDraw simulation.

  • PDF

An Algorithm of fault Location Technique for Long Transmission Line (송전선로의 고장점 표정 알고리즘)

  • Park, C.W.;Kim, S.R.;Shin, M.C.;Nam, S.B.;Lee, B.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.145-147
    • /
    • 2002
  • In this paper, the improved fault locating method using distributed parameter which calculating the reduced voltage and current according to the ground capacitance in long transmission line was proposed. For the purpose of the fault locating algorithm non influenced source impedance, the loop method was used in the system modeling analysis. To enhance the fault locating, zero sequence of the fault current which is variable according to ground capacitance was not used but positive and negative sequence. System model was simulated using EMTP software. To verify the accuracy of proposed method, in different cases 64 sampled data per cycle was used and 160km and 300km long transmission line has fault resistance $0{\Omega}\;and\;100{\Omega}$ respectively was compared.

  • PDF

A Study on the Characteristic and Rising Cause of Sheath Circulating Current by Analysis and Measurement (해석 및 측정을 통한 시스순환전류 특성 및 상승원인 검토)

  • Gang, Ji-Won;Yang, Hae-Won
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.10
    • /
    • pp.525-533
    • /
    • 2002
  • It is common to install multiple lines in the same route. Recently, excessive sheath circulating current was partially measured in underground cable systems of KEPCO. Especially, the installation type, unbalance section length between joint boxes and zero sequence current by distribution cable have an effect on the rising of sheath circulating current in the underground transmission system. If excessive current flows in sheath, sheath loss which is reduced the transmission capacity is produced. This paper describes the relation analysis of sheath circulating current and burying types. And also, a detailed analysis on rising cause and characteristic of sheath circulating current by considering various unbalanced conditions presents using analysis and measurement regarding cable systems which have the problem of excessive sheath circulation current.

345/154 kV Transmission Line model choice and calculation using TMLC (TMLC용 345, 154kV 송전선로 모델 작성 및 계산)

  • Choi, H.K.;Moon, Y.H.;Yoon, J.Y.;Choo, J.B.;Yun, Y.B.;Kim, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.336-339
    • /
    • 2001
  • Transmission line data are very important for studying loadflow. Short circuit data(positive sequence, zero sequence) of 345kV and 154kV line were calulated and compared with KEPCO's line characteristics data. This Paper presents method of verification and complement of line data in PSS/E loadflow data using TMLC (Transmission Line Characteritics) program.

  • PDF

A Study on Fault Detecting for Underground Power Transmission Lines using Optical Field Sensors (광응용 자계센서를 이용한 지중송전선 사고구간 검출에 관한 연구)

  • Lee, Kwang-Jung;Kim, Seok-Koo;Park, Hae-Soo;Kim, Yo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.91-93
    • /
    • 1994
  • Recently, for improving the power supply reliability and for rationslizing maintenance, new maintenance and monitoring systems are stornagly desired for use in the field of electric power transmission. In this paper, we describes the optical fault detecting method of underground power transmission lines using bareearth doped YIG Faraday sensors which are very light, small size and fast response. As regarding, we use the zero phase current detecting algorithm at insulated joints.

  • PDF

A Novel Compact Metamaterial Zeroth Order Resonant Bandpass Filter for a VHF Band and Its Stopband Improvement by Transmission Zeros

  • Kahng, Sungtek;Jang, Geonho
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.4
    • /
    • pp.263-266
    • /
    • 2013
  • A novel compact and low-loss VHF bandpass filter is presented with enhanced stopband performance using metamaterial zeroth order resonator (ZOR) characteristics. An in-line ZOR filter is initially suggested and changed to have transmission zeros (TZs) due to source-load coupling for effective improvement of the isolation from UHF wireless channels. The proposed filter is smaller than 1/10 of the conventional filters in terms of size and has relatively very low insertion loss (< 1 dB for the electromagnetic (EM) simulation and < 3 dB for the measurement) and return loss (<-20 dB) in the passband due to the approximately 80% size reduction and the higher isolation in the stopband due to the TZs. The circuit and EM simulation are in good agreement with the measurements.

Transmission System Expansion Planning Using Branch and Bound (분기 한정법에 의한 송전계통의 확충 계획)

  • Tran, Trungtinh;Kang, Sung-Rok;Kim, Kuen-Ho;Lee, Ji-Hoon;Choi, Jae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.46-49
    • /
    • 2003
  • This paper proposes a method to solve expansion problem for a transmission network, given future generation and load strategy, and alternative types of lines available, subject to load, reliability and right of way constraints, the problem is formulated as a series of zero one integer programs which are solved by an efficient branch and bound algorithm A study test result on the 63-buses test system shows that the proposed method is practical and efficiently applicable to the transmission expansion planning.

  • PDF

A Study on the Technique of Fault Classification in Transmission Lines Using a Combined Adaptive Network-Based Fuzzy Inference System (ANFIS를 이용한 송전선로의 고장판별 기법에 관한 연구)

  • Yeo, Sang-Min;Kim, Cheol-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.9
    • /
    • pp.417-423
    • /
    • 2001
  • This paper proposes a technique for fault detection and classification for both LIF(Low Impedance Fault)s and HIF(High Impedance Fault)s using Adaptive Network-based Fuzzy Inference System(ANFIS). The inputs into ANFIS are current signals only based on Root-Mean-Square(RMS) values of 3-phase currents and zero sequence current. The performance of the proposed technique is tested on a typical 154 kV Korean transmission line system under various fault conditions. Test results show that the ANFIS can detect and classily faults including (LIFs and HIFs) accurately within half a cycle.

  • PDF

Millimeter Wave Filtres using a high Q MMIC Transmission Line (높은 Q값을 가지는 MMIC 전송선을 이용한 밀리미터파 필터)

  • Liamas-Garro, Ignacio;Kim, Yong-Sung;Baek, Chang-Wook;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2383-2385
    • /
    • 2005
  • In this paper we discuss the design and fabrication of two millimeter wave filters, in bandpass and bandstop topologies for wireless communications applications. The filters are made using a high Q MMIC transmission line, which consists of a 100 micrometers tall, surface micromachined, air filled inverted microstrip structure on a quartz substrate, made by using a JSR THB-151N negative photoresist sacrificial layer mold and electroplating technology. The filter topologies include a new, very compact, four pole, cross-coupled filter, that presents a single transmission zero at the lower side of the passband, which provides a very sharp out of passband rejection at this region.

  • PDF

On the efficient transmission of video stream using characteristic information (특성 정보를 이용한 비디오 스트림의 효율적 전송)

  • 강수용;염헌영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.9
    • /
    • pp.2328-2340
    • /
    • 1996
  • Until now, the transmission of data for VOD(Video on Demenad) was based on a real time modelling of video data. Markow Modulated Fluid Sources(MMFS) and Markow Modulated Poisson Sources(MMPS) are the most widely used modelling methods. But the charactersitics of the VBR(Variable Bit Rate) signal prevents modelling from actually being "real-time". Also these methods call for the use of large buffers for the abolishment of cell loss. These modelling methods are, of course, useful i case of teleconferences where a real time modelling of video traffic is inevitable, but they are insufficient in cases where the characteristic infomation of video traffic can be obtained beforehand-cases such as VOD. Video data is speial in that if one file is preprocessed all other products can simply be copied from that onepreprocessed file. This characteristic helps reduce the overhead arising from the job of drawing out characteristic information to almost zero. But still, compared to the existing real time modelling method data transmission using characteristic information succeeds in raising the efficiency of data transmission. In tis paper we will outline a method of dta transmission which use the characteristic information of each video stream, and evaluate this method through some experiments.periments.

  • PDF