• 제목/요약/키워드: Transmission Zero

검색결과 333건 처리시간 0.02초

Simulation for current limiting characteristics of the resistive and inductive SFCL with line-to-ground fault

  • Choi, Hyo-Sang;Hwang, Si-Dole;Kim, Sang-Joon;Han, Byoung-Sung
    • Progress in Superconductivity
    • /
    • 제1권1호
    • /
    • pp.73-80
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with 100 $\Omega$ of impedance for line-to-ground faults in the 154 kV transmission system. The fault simulation at the phase angles $0^{\circ}$, $^45{\circ}$, and $90^{\circ}$ showed that the resistive SFCL limits the fault current less than 17 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppresses the current below 14 kA, but with 5 kA of DC component which decreases to zero in 5 cycles. We concluded that the inductive SFCL has higher performance in current limiting effect, but the resistive SFCL was better from the viewpoint of less DC components.

  • PDF

전력계통안정도 계산앨고리즘의 개선에 관한 연구 (A new algorithm for power system stability calculations)

  • 박영문
    • 전기의세계
    • /
    • 제29권3호
    • /
    • pp.193-200
    • /
    • 1980
  • A new algorithm for power system stability calculations is developed which considers the nonlinear state equations of 8 state variables for each generator dynamics, expollential load models in respect to bus voltages for nonlinear loads, network equations expressed in terms of bus-injected current sources, various kinds of generator and transmission line outages, abrupt changes in loads, and operations of various kinds of portective relaying systems such as distance relaying, reclosing load shedding by under-frequency relays. In the algorithm are included efficient and reliable schemes for solving network equations by means of the Newton-Raphson iterative method and the Optimally-Ordered Triangular Factorization Technique, and simple procedures for determining fault-point negative and zero sequence impedances for unbalanced line faults. An application of the Optimally-Ordered Triangular Factorization Techniques results in remarkable savings in computing time and memory requirements.

  • PDF

Microstrip Bandpass Filter Using Stepped-Impedance Coupled-Line Hairpin Resonators with Enhanced Stopband Performance

  • Lee, Hye-Min;Ha, Jung-Hyun;Wang, Xu-Guang;Cho, Young-Ho;Yun, Sang-Won
    • Journal of electromagnetic engineering and science
    • /
    • 제11권2호
    • /
    • pp.91-96
    • /
    • 2011
  • In this paper, we propose a microstrip bandpass filter using stepped-impedance coupled-line hairpin resonators. The stepped-impedance coupled-line hairpin resonator has extended harmonic suppression in comparison with a conventional hairpin resonator due to transmission zero and the movement of harmonic frequencies resulting from the stepped-impedance characteristic. A high-pass type impedance/admittance inverter is employed in order to improve the lower frequency skirt characteristics of the passband. A 4-pole bandpass filter is designed and fabricated at 1.8 GHz. The measured results show the excellent attenuation performance at the stopband which is greater than 30 dB up to 10 GHz.

154kV급 전력-광복합케이블의 개발 (Development of the 154kV optical fiber incorporated power cable)

  • 류재규;유성종;전승익;조진철;최봉남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1639-1641
    • /
    • 1997
  • In this study, We developed the 154kV optical fiber incorporated power cable which is combined optical fibers with conventional 154kV power cable. Also, we developed optical unit that optical fiber is inserted in stainless tube. The optical unit was tested, and we got good results enough to safe optical fibers. Also we put the optical fiber incorporated power cable to the test of electrical characteristics and optical characteristics, we knew that the electrical characteristics were the same characteristics as conventional 154kV power cable and the transmission loss change was almost zero. The method of optical unit connection was examined.

  • PDF

Multi-coated YBa2Cu3O7-x Films Fabricated by a Fluorine-Free Sol-Gel Process

  • Cho, E.A.;Jang, G.E.;Hyun, O.B.
    • Journal of Magnetics
    • /
    • 제16권2호
    • /
    • pp.186-191
    • /
    • 2011
  • [ $YBa_2C_3O_{7-x}$ ]films were fabricated on a $SrTiO_3$ (100) substrate using a trimethylaceate propionic acid (TMAP)-based MOD process by controlling the precursor solution viscosity, firing temperature, and by using various coatings. The viscosity of the precursor solution was controlled by the addition of Xylenes. The films were heat treated with different temperatures from 750 to $800^{\circ}C$. c-axis oriented films were obtained. After adding 9 ml of Xylene into the precursor solution, the $T_c$ of the YBCO film, which was coated 2 times and heat treated at $800^{\circ}C$, was 86 K and the measured $J_c$ was above 2.5 MA/$cm^2$ at 77 K in a zero-field.

저항형과 유도형 한류기의 전류제한특성에 대한 EMTDC 해석 (EMTDC simulation for current limiting characteristics of the resistive and inductive SFCL)

  • 최효상;황시돌;현옥배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.255-258
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with 100 $\Omega$ of quench impedance for a single line-to-ground fault. which accounts for about 70% of the total power line faults, in the 154 kV transmission system. The fault simulation at the phase angles 0$^{\circ}$, 45$^{\circ}$, and 90$^{\circ}$ showed that the resistive SFCL limited the fault current less than 15 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppressed the current below 12 KA, but with 3 kA of DC component which decreased to zero in 5 cycles. We concluded that the inductive SFCL had higher performance in current limiting but the resistive SFCL was better from the view point of DC components.

  • PDF

Adaptive Channel-Matched Extended Alamouti Space-Time Code Exploiting Partial Feedback

  • Badic, Biljana;Rupp, Markus;Weinrichter, Hans
    • ETRI Journal
    • /
    • 제26권5호
    • /
    • pp.443-451
    • /
    • 2004
  • Since the publication of Alamouti's famous space-time block code, various quasi-orthogonal space-time block codes (QSTBC) for multi-input multi-output (MIMO) fading channels for more than two transmit antennas have been proposed. It has been shown that these codes cannot achieve full diversity at full rate. In this paper, we present a simple feedback scheme for rich scattering (flat Rayleigh fading) MIMO channels that improves the coding gain and diversity of a QSTBC for 2$^n$ (n=3, 4, ${\cdots}$) transmit antennas. The relevant channel state information is sent back from the receiver to the transmitter quantized to one or two bits per code block. In this way, signal transmission with an improved coding gain and diversity near to the maximum diversity order is achieved. Such high diversity can be exploited with either a maximum-likelihood receiver or low-complexity zero-forcing receiver.

  • PDF

Effect of Columnar Structures on Exchange Anisotropy Field in Magnetoresistive NiO/NiFe Bilayers

  • Jai-Young Kim;Gyeong-Su Park;Jae-Chul Ro;Su-Jeong Suh
    • Journal of Magnetics
    • /
    • 제4권3호
    • /
    • pp.88-91
    • /
    • 1999
  • A series of NiO/NiFe bilayer films are deposited with the variation of Ar sputtering pressure for the NiO layers only. As the pressure for the NiO layers increases, the exchange anisotropy field (HEX) decreases gradually and becomes extinct at 2.5 mTorr, at which the maximum coercive force (HC) in the NiO/NiFe films is obtained. Randomly oriented columnar structures with HEX a few tens of Oe and oriented columnar structures with zero HEX are observed in the NiP layers by highvoltage hihg-resolution transmission electron microscopy. The vanishing of the HEX in the oriented structures is attributed to the lack of exchange anisotropy energy (EEX) between NiO and NiFe layers, which results in little contribution of interfacial unidirectional pinning anisotropy to the interface of NiO/NiFe bilayer.

  • PDF

분할등화기를 이용한 개선된 비적적응필터 (Improved Multiplication Free Adaptive Digital Filter with the Fractionally-Spaced Equalizer)

  • Yoon, Dal-Hwan
    • 대한전자공학회논문지SP
    • /
    • 제39권2호
    • /
    • pp.137-146
    • /
    • 2002
  • 데이터 전송채널에서 부호간간섭(ISI)을 제거하기 위해 개선된 비적적응 디지털필터(IMADF)의 구조와 수렴해석이 이루어진다. 0평균, 백색잠음하에서 분할등화기(FSE)를 이용한 IMADF의 수렴특성을 해석한다. 실험결과 IMADF 알고리즘의 수렴독성이 Sign 알고리즘과는 같으나, MADF 알고리즘 보다 우수하다. 특히 입력신호의 상관관계가 높을 때 유용한 특성을 갖는다.

Alternative Expressions for Mutual Inductance and Coupling Coefficient Applied in Wireless Power Transfer

  • Kim, Gunyoung;Lee, Bomson
    • Journal of electromagnetic engineering and science
    • /
    • 제16권2호
    • /
    • pp.112-118
    • /
    • 2016
  • Alternative analytic expressions for the mutual inductance ($L_m$) and coupling coefficient (k) between circular loops are presented using more familiar and convenient expressions that represent the property of reciprocity clearly. In particular, the coupling coefficients are expressed in terms of structural dimensions normalized to a geometric mean of radii of two loops. Based on the presented expressions, various aspects of the mutual inductances and coupling coefficients, including the regions of positive, zero, and negative value, are examined with respect to their impacts on the efficiency of wireless power transmission.