• 제목/요약/키워드: Transmission X-ray

검색결과 1,286건 처리시간 0.022초

W-target 투과 양극형 Soft x-ray tube의 개발 및 특성분석 (Development and Characteristics of the Soft x-ray transmission W-target tube)

  • 김성수;김도윤
    • 한국진공학회지
    • /
    • 제16권4호
    • /
    • pp.305-310
    • /
    • 2007
  • W-target 투과양극형 x-ray tube를 개발하고, 특성을 조사하였다. 관전압이 12kV이하에서는 연속 x-ray만 방출되었고, 12kV 이상에서부터 특성 x-ray가 관측되었다. 연속 x-ray와 특성 x-ray의 에너지 분포 및 선량 특성을 조사한 결과 알려진 결과와 잘 일치함을 알 수 있었다. 또한 상용화된 제품과의 비교에서, 기존 제품 이상의 성능을 가질 수 있음을 확인하였다. 따라서 본 연구에서 개발된 x-ray tube는 상용화할 수 있을 만큼 충분히 우수한 특성을 가지고 있음을 확인하였다.

Determination of Tungsten Target Parameters for Transmission X-ray Tube: A Simulation Study Using Geant4

  • Nasseri, Mohammad M.
    • Nuclear Engineering and Technology
    • /
    • 제48권3호
    • /
    • pp.795-798
    • /
    • 2016
  • Transmission X-ray tubes based on carbon nanotube have attracted significant attention recently. In most of these tubes, tungsten is used as the target material. In this article, the well-known simulator Geant4 was used to obtain some of the tungsten target parameters. The optimal thickness for maximum production of usable X-rays when the target is exposed to electron beams of different energies was obtained. The linear variation of optimal thickness of the target for different electron energies was also obtained. The data obtained in this study can be used to design X-ray tubes. A beryllium window was considered for the X-ray tube. The X-ray energy spectra at the moment of production and after passing through the target and window for different electron energies in the 30-110 keV range were also obtained. The results obtained show that with a specific thickness, the target material itself can act as filter, which enables generation of X-rays with a limited energy.

40kV용 투과양극형 x-ray tube에 의한 X-ray 형광 특성 (Characteristics of the X-ray Fluorescence by the 40kV transmission anode x-ray tube)

  • 김성수;김도윤
    • 한국진공학회지
    • /
    • 제17권3호
    • /
    • pp.247-252
    • /
    • 2008
  • 휴대용 XRF(X-Ray Fluorescence) 장치에 적용하기 위하여 개발한 투과 양극형 x-ray tube를 이용하여 XRF 실험을 하고, x-ray tube가 XRF data에 미치는 영향을 조사하였다. W-target tube와 Rh-target tube를 이용하여 측정한 XRF data는 알려진 결과와 잘 일치하였다. 35 kV와 관전압과 $40{\mu}A$의 관전류에서 W-target tube로 측정한 Fe $K_{\alpha}$-line의 FWHM은 약 180 eV로써, 이 값은 물질의 성분분석을 하기에 충분한 것으로 확인하였다. XRF data와 x-ray tube의 적분강도 곡선을 비교 분석해 본 결과, 휴대용 XRF 장치에는 W-Target tube보다는 Rh-Target tube를 사용하는 것이 더 유리함을 밝혀내었다.

필름 두께 측정용 투과 양극형 x-ray tube의 개발 및 특성 (Development and Characteristics of the x-ray transmission anode tube for the thickness measurement of film)

  • 김성수;김도윤
    • 한국진공학회지
    • /
    • 제17권3호
    • /
    • pp.240-246
    • /
    • 2008
  • 수십에서 수백 ${\mu}m$ 영역의 필름 두께 측정에 적용하기 위한 Ag-target 투과양극형 x-ray tube를 개발하고 특성을 조사하였다. 10kV 부근의 관전압에서 x-ray 에너지의 분포 및 선량특성을 조사하고 W-target tube와 비교하여 논의하였다. 또한 Ag-target tube와 W-target tube를 이용하여 Ny film과 PP film의 두께변화에 따른 x-ray의 투과 특성으로 조사하였고, 그 결과 개발된 x-ray tube는 필름두께 측정용으로 적용할 수 있을 만큼 충분히 좋은 특성을 나타내었다.

40kV용 투과 양극형 x-ray tube의 개발 및 특성분석 (Development and its Characteristics of the 40kV x-ray transmission anode target tube)

  • 김성수;김도윤
    • 한국진공학회지
    • /
    • 제17권3호
    • /
    • pp.234-239
    • /
    • 2008
  • 휴대용 XRF (X-Ray Fluorescence) 장치에 적용할 수 있는 40 kV용 투과 양극형 W-Target tube와 Rh-Target tube를 개발하고 특성을 조사하였다. 특성 x-ray의 에너지와 연속 x-ray의 선량특성은 알려진 결과와 잘 일치함을 확인하였고, 최대 선량을 추출하기 위한 양극금속 박막의 최적 두께는 W-target tube의 경우 약 $2.6{\mu}m$, Rh-target tube의 경우 약 $2.7{\mu}m$ 임을 밝혀내었다. 또한 관전압 40 kV, 관전류 $60{\mu}A$로 30분 동안 연속적으로 작동시켰을 때 양극에서의 온도는 $50^{\circ}C$를 넘지 않아 휴대용 XRF장치에 적용할 수 있음을 확인하였다.

이중 적층 구조 표적을 갖는 투과형 엑스선관의 몬테카를로 전산모사 (Monte Carlo Simulation of Transmission-Type X-ray Tube with Dual-Structured Target)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제17권1호
    • /
    • pp.107-114
    • /
    • 2023
  • 엑스선형광분석은 비파괴적으로 시료에 포함된 원소와 농도를 분석할 수 있는 기법으로 과학 및 산업 분야에 광범위하게 사용되고 있다. 다양한 물질을 포함한 혼합물 또는 화합물 분석의 정밀도 향상을 위해 10 keV 근방의 저에너지와 20 keV 근방의 에너지 영역에 높은 강도 분포를 갖는 엑스선관이 요구된다. 두 에너지 영역에서 높은 강도 분포를 갖는 스펙트럼을 얻기 위하여 9.65 keV의 특성엑스선을 가지는 텅스텐과 17.48 keV의 몰리브덴 두 물질을 적층한 구조의 표적을 가지는 투과형 엑스선관을 몬테카를로 전산모사를 통해 스펙트럼을 분석하였다. W-Mo 구조의 표적을 통해 10 keV와 20 keV 근방의 강한 강도를 갖는 특성엑스선을 얻었다. 또한 4 ㎛ 두께의 Mo-W multilayers 구조의 표적을 통해 최적의 강도 분포를 갖는 스펙트럼을 얻을 수 있음을 확인하였다. 다양한 표적 물질을 선택 조합하고 두께 최적화를 통해 원하는 에너지 대역에서 높은 강도 분포를 갖는 스펙트럼을 얻는 것이 가능하다.

Thickness-dependent magnetic domain structures of Co ultra-thin film investigated by scanning transmission X-ray microscopy

  • Yoon, Ji-Soo;Kim, Namdong;Moon, Kyoung-Woong;Lee, Joo In;Kim, Jae-Sung;Shin, Hyun-Joon;Kim, Wondong
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1185-1189
    • /
    • 2018
  • Thickness-dependent magnetic domain structure of ultrathin Co wedge films (0.3 nm-1.0 nm) sandwiched by Pt layers was investigated by scanning transmission x-ray microscopy (STXM) employing X-ray magnetic circular dichroism (XMCD), utilizing elliptically polarized soft x-rays and electromagnetic fields, with a spatial resolution of 50 nm. The magnetic domain images measured at the Co $L_3$ edge showed the evolution of the magnetic domain structures from maze-like form to the bubble-like form as the perpendicular magnetic field was applied. The asymmetric domain expansion of a 500 nm-scale bubble domain was also measured when the in-plane and perpendicular external magnetic field were applied simultaneously.

X-선 투과검사를 이용한 저항 점용접부 품질평가기법 (Weld Quality Evaluation Method for the Resistance Spot Welds using X-ray Transmission Inspection)

  • 이종대;이소정;방정환;윤길상;김목순;김준기
    • Journal of Welding and Joining
    • /
    • 제32권6호
    • /
    • pp.1-7
    • /
    • 2014
  • For the resistance spot welds of CR1180 and GA1180 TRIP steels, the weld quality evaluation method using the digitalized X-ray transmission imaging apparatus was investigated in comparison with the crosssectional examination method. In the case of the resistance spot welding of CR1180, three circular regions, such as WZ(white zone), GZ(grey zone) and DZ(dark zone), appeared on X-ray image and they corresponded to the diameters of indentation mark, nugget and corona bond, respectively. The variation of X-ray transmission thickness due to the thickness variation of the weld seemed to be mainly responsible for the formation of those contrasts. The X-ray image contrast formed from the variation of transmission thickness at the outer border line of DZ could also enable the inspections of the notch shape, nonuniformity of the welding pressure and spatter from its sharpness, concentricity and the normal straight line, respectively. The X-ray image of the resistance spot weld of galvannealed GA1180 TRIP steel was very similar to that of CR1180 TRIP steel except the crown shaped outer border line of DZ which was considered to be due to the melting behavior of zinc having the boiling temperature even lower than the melting temperature of steel.

투과선량의 수치해석에 의한 전산화단층영상장치 X선의 에너지 분포결정 (Empirical Determination of a CT X-ray Spectra by Numerical Analysis using Transmission Data)

  • 최태진;김옥배;서수지
    • 한국의학물리학회지:의학물리
    • /
    • 제8권2호
    • /
    • pp.35-43
    • /
    • 1997
  • 광자선의 흡수계수교정과 차등 투과력이 관련된 연구에서 X선의 스펙트럼은 중요한 관심사이다. 본 연구에서는 전산화단층영상장치의 80, 120 kVp X선의 실험적 투과선량으로부터 수치해석을 통해 에너지스펙트럼을 구하였다. 투과선량은 직경 30cm, 두께 5mm 내지 92.3 mm의 알루미늄 파이프필터의 중앙에 반도체검출기를 설치하고 10mm 슬릿빔의 투과선량을 측정하였다. 스펙트럼재구성은 텅스텐타켓의 특성 X선을 포함한 반복적 수치 해석을 통해 에너지 구간별 스펙트럼을 구하였으며 에너지구간은 2keV로 하였다. 재구성한 에너지분포를 이용하여 계산된 투과선량과 측정투과선량의 비교는 두 광자에너지에서 모두 좋은 일치를 보였다. 에너지구간별 분할조사선량의 반복적 계산에 근거를 둔 수치해석은 흡수체의 감쇄된 선속으로부터 X선의 에너지스펙트럼을 매우 유용하게 결정할 수 있음을 보여주었다.

  • PDF

Advanced Nanoscale Characterization of Cement Based Materials Using X-Ray Synchrotron Radiation: A Review

  • Chae, Sejung R.;Moon, Juhyuk;Yoon, Seyoon;Bae, Sungchul;Levitz, Pierre;Winarski, Robert;Monteiro, Paulo J.M.
    • International Journal of Concrete Structures and Materials
    • /
    • 제7권2호
    • /
    • pp.95-110
    • /
    • 2013
  • We report various synchrotron radiation laboratory based techniques used to characterize cement based materials in nanometer scale. High resolution X-ray transmission imaging combined with a rotational axis allows for rendering of samples in three dimensions revealing volumetric details. Scanning transmission X-ray microscope combines high spatial resolution imaging with high spectral resolution of the incident beam to reveal X-ray absorption near edge structure variations in the material nanostructure. Microdiffraction scans the surface of a sample to map its high order reflection or crystallographic variations with a micron-sized incident beam. High pressure X-ray diffraction measures compressibility of pure phase materials. Unique results of studies using the above tools are discussed-a study of pores, connectivity, and morphology of a 2,000 year old concrete using nanotomography; detection of localized and varying silicate chain depolymerization in Al-substituted tobermorite, and quantification of monosulfate distribution in tricalcium aluminate hydration using scanning transmission X-ray microscopy; detection and mapping of hydration products in high volume fly ash paste using microdiffraction; and determination of mechanical properties of various AFm phases using high pressure X-ray diffraction.