• Title/Summary/Keyword: Transmission Tomography

Search Result 71, Processing Time 0.028 seconds

Correlation between Physical Defects and Performance in AlGaN/GaN High Electron Mobility Transistor Devices

  • Park, Seong-Yong;Lee, Tae-Hun;Kim, Moon-J.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.2
    • /
    • pp.49-53
    • /
    • 2010
  • Microstructural origins of leakage current and physical degradation during operation in product-quality AlGaN/GaN high electron mobility transistor (HEMT) devices were investigated using photon emission microscopy (PEM) and transmission electron microscopy (TEM). AlGaN/GaN HEMTs were fabricated with metal organic chemical vapor deposition on semi-insulating SiC substrates. Photon emission irregularity, which is indicative of gate leakage current, was measured by PEM. Site specific TEM analysis assisted by a focused ion beam revealed the presence of threading dislocations in the channel below the gate at the position showing strong photon emissions. Observation of electrically degraded devices after life tests revealed crack/pit shaped defects next to the drain in the top AlGaN layer. The morphology of the defects was three-dimensionally investigated via electron tomography.

Penetrating Neck Trauma by Gunshot Injury: 1 Case Report (총상에 의한 경부 관통상 -치험 1례-)

  • Hong, Yoon Joo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.9 no.1
    • /
    • pp.95-99
    • /
    • 2005
  • Penetrating neck trauma by gunshot injury involving tracheobronchial tree is rare in Korea. Extensive tissue damage by cavitation, tissue fragmentation and shock wave transmission of high-velocity projectile along with associated organ injury renders high rate of mortality and morbidity. A 28 year old man in military service with gunshot wound in left cervical area presented initial symptoms of severe dyspnea and subcutaneous emphysema. Computed tomography of chest and cervical region as well as bronchoscopic evaluation was performed to confirm highly suspected injury to cervical trachea. Surgical exposure was established through a low collar incision; the damaged segment of 3.5 cm length including 2-4th tracheal rings was resected out and end-to-end anastomosis was performed. Bleeding from lacerated anterior jugular vein was controlled by ligation of both ends and a K2 bulllet was found upon inner border of body of first rib, medial to right carotid sheath and removed out. Cervical esophagus, carotid artery, internal jugular vein and recurrent laryngeal nerve were spared. Extubation was done on the first postoperative day and postoperative course until discharge on nineth postoperative day remained uneventful.

  • PDF

Experiences of Emergency Surgical Treatment for a COVID-19 Patient with Severe Traumatic Brain Injury at a Regional Trauma Center: A Case Report

  • Yun, Jung-Ho
    • Journal of Trauma and Injury
    • /
    • v.34 no.3
    • /
    • pp.212-217
    • /
    • 2021
  • Various medical scenarios have arisen with the prolonged coronavirus disease 2019 (COVID-19) pandemic. In particular, the increasing number of asymptomatic COVID-19 patients has prompted reports of emergency surgical experiences with these patients at regional trauma centers. In this report, we describe an example. A 25-year-old male was admitted to the emergency room after a traffic accident. The patient presented with stuporous mentality, and his vital signs were in the normal range. Lacerations were observed in the left eyebrow area and preauricular area, with hemotympanum in the right ear. Brain computed tomography showed a contusional hemorrhage in the right frontal area and an epidural hematoma in the right temporal area with a compound, comminuted fracture and depressed skull bone. Surgical treatment was planned, and the patient was intubated to prepare for surgery. A blood transfusion was prepared, and a central venous catheter was secured. The initial COVID-19 test administered upon presentation to the emergency room had a positive result, and a confirmatory polymerase chain reaction (PCR) test was administered. The PCR test confirmed a positive result. Emergency surgical treatment was performed because the patient's consciousness gradually deteriorated. The risk of infection was high due to the open and unclean wounds in the skull and brain. We prepared and divided the COVID-19 surgical team, including the patient's transportation team, anesthesia team, and surgical preparation team, for successful surgery without any transmission or morbidity. The patient recovered consciousness after the operation, received close monitoring, and did not show any deterioration due to COVID-19.

A Brief Review of κ-Carbide in Fe-Mn-Al-C Model Alloys

  • Seol, Jae Bok
    • Applied Microscopy
    • /
    • v.48 no.4
    • /
    • pp.117-121
    • /
    • 2018
  • The multiple length scale analysis of previously designed Fe-Mn-Al-C based low-density model alloys reveals the difference in ordered ${\kappa}-carbide$, $(Fe,Mn)_3AlC_x$, between Fe-25Mn-16Al-5.2C (at%) alloy and Fe-3Mn-10Al-1.2C (at%) alloy. For the former alloy composition consisting of fully austenite grains, ${\kappa}-carbide$ showed majorly cuboidal and minorly pancake morphology and its chemical composition was not changed through aging for 24 h and 168 h at $600^{\circ}C$. Meanwhile, for the isothermally annealed ferritic alloy system for 1 hr at 500 and $600^{\circ}C$, the dramatic change in the chemical composition of needle-shape ${\kappa}-carbide$, $(Fe,Mn)_3(Fe,Al)C_x$, was found. Here we address that the compositional fluctuations in the vicinity of the carbides are significantly controlled by abutting phase, either austenite or ferrite. Namely, the cooperative ordering of carbon and Al is an important factor contributing to carbide formation in the high-Mn and high-Al alloyed austenitic steel, while the carbon and Mn for the low-Mn and high Al alloyed ferritic steel.

Manufacturing Technique and Conservation of Bigyeokjincheolloe Bomb Shells Excavated from the Ancient Local Government Office and Fortress of Mujang-hyeon, Gochang (고창 무장현 관아와 읍성 출토 비격진천뢰의 제작기법과 보존처리)

  • Kim, Haesol;Huh, Ilkwon
    • Conservation Science in Museum
    • /
    • v.24
    • /
    • pp.17-36
    • /
    • 2020
  • This paper describes the consevation treatment of eleven bigyeokjincheolloe bomb shells that were excavated from the Joseon-period local government office and fortress of Mujang-hyeon (present-day Mujang-myeon) in Gochang in 2018. It also provides information on the production method of the shells revealed through CT scanning, gamma-ray transmission imaging, and metallographic analysis. In preparation for the special exhibition "Bigyeokjincheolloe" at the Jinju National Museum in 2019 (July 16 to August 25), contaminants were removed from the shells and their surface was reinforced during the first phase of conservation treatment. Furthermore, the closures for the shells were identified for the first time. Regarding the production of the shells, the CT scanning and gamma-ray transmission imaging identified many blowholes in the interior of the body and the use of a chaplet on the side of one shell. The side of the body proved to be relatively thinner than the top and bottom. The traces of a hole for pouring molten metal into the center of the bottom indicates that molten metal was indeed emptied into the inverted body. In the metallographic analysis of two of the bodies and one lid, cementite and pearlite structures were identified on the body, indicating that it was made by casting. The presence of the ferrite structure with a partial distribution of the pearlite along with non-metallic inclusion in the lid suggested that the lid was made by forging.

Physicochemical properties of the materials used for the production of celadon maebyeong inlaid with cloud-and-crane designs and changes in their morphological properties by production stage (청자상감운학문매병 제작 재료의 물리화학적 특성 및 제작 단계별 형상학적 특성 변화)

  • Kim, Jihye;Ha, Jihyang;Han, Minsu
    • Conservation Science in Museum
    • /
    • v.25
    • /
    • pp.63-84
    • /
    • 2021
  • In order to investigate the diverse physicochemical changes that occurred in traditional Korean pottery during its production, including before and after firing, this study produced six replicas of a celadon maebyeong inlaid with cloud-and-crane designs, respectively corresponding to the process of shaping, carving, inlaying designs, first firing, glazing and second firing, respectively. It then conducted a scientific study of these six replicas and analyzed their images through high-resolution three-dimensional transmission imaging. The materials used for the replicas show different mineral phases and even colors depending on the components of each material. For example, black inlay with a high content of iron oxide (Fe2O3) shows dark colors and white inlay with a high alumina (Al2O3) content appears white. Physicochemical properties such as chromaticity and magnetic susceptibility and major components of the replicas were confirmed by the differences in the density in the computed tomography (CT) images. The characteristics of fired products such as fine structure, absorption ratio, apparent porosity, and other characteristics of the major mineral components were identified by the presence of pores and the formation of cracks inside the replicas in the image analysis.

Layered structure of sialoliths compared with tonsilloliths and antroliths

  • Buyanbileg Sodnom-Ish;Mi Young Eo;Yun Ju Cho;Mi Hyun Seo;Hyeong-Cheol Yang;Min-Keun Kim;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.50 no.1
    • /
    • pp.13-26
    • /
    • 2024
  • Objectives: The aim of this study was to perform a comparative analysis of the ultrastructural and chemical composition of sialoliths, tonsilloliths, and antroliths and to describe their growth pattern. Materials and Methods: We obtained 19 specimens from 18 patients and classified the specimens into three groups: sialolith (A), tonsillolith (B), and antrolith (C). The peripheral, middle, and core regions of the specimens were examined in detail by histology, micro-computed tomography (micro-CT), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy, and transmission electron microscopy (TEM). Results: In the micro-CT, group A showed alternating radiodense and radiolucent layers, while group B had a homogeneous structure. Group C specimens revealed a compact homogeneous structure. Histopathologically, group A showed a laminated, teardrop-shaped, globular structure. Group B demonstrated degrees of immature calcification of organic and inorganic materials. In group C, the lesion was not encapsulated and showed a homogeneous lamellar bone structure. SEM revealed that group A showed distinct three layers: a peripheral multilayer zone, intermediate compact zone, and the central nidus area; groups B and C did not show these layers. The main elemental components of sialoliths were O, C, Ca, N, Cu, P, Zn, Si, Zr, F, Na, and Mg. In group B, a small amount of Fe was found in the peripheral region. Group C had a shorter component list: Ca, C, O, P, F, N, Si, Na, and Mg. TEM analysis of group A showed globular structures undergoing intra-vesicular calcification. In group B, bacteria were present in the middle layer. In the outer layer of the group C antrolith, an osteoblastic rimming was observed. Conclusion: Sialoliths had distinct three layers: a peripheral multilayer zone, an intermediate compact zone and the central nidus area, while the tonsillolith and antrolith specimens lacked distinct layers and a core.

Fungal Osteomyelitis of Temporomandibular Joint and Skull Base Caused by Chronic Otitis Media

  • Kim, Bok Eum;Park, Keun Jeong;Lee, Jung Eun;Park, YounJung;Kwon, Jeong-Seung;Kim, Seong-Taek;Choi, Jong-Hoon;Ahn, Hyung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.45 no.1
    • /
    • pp.12-16
    • /
    • 2020
  • Chronic otitis media (COM) is a chronic inflammatory disease which affects the middle ear, mastoid cavity. It presents hearing loss, ear pain, dizziness, headache, temporomandibular joint (TMJ) inflammation and intracranial complication. Intracranial complications such as skull base osteomyelitis (SBO) may occur secondary to COM due to transmission of infection by a number of possible routes. SBO is an uncommon condition with a significant morbidity and mortality if not treated in the early stages. We report a-67-year-old male patient with diabetes and untreated COM who presented atypical severe TMJ, periorbital and postmandibular pain. By computerized tomography (CT), magnetic resonance imaging (MRI) and whole body bone scan (WBBS), he was diagnosed with SBO spreading from untreated COM via infective arthritis of TMJ. Through this case, we suggest proper utilization of diagnostic imaging, especially CT or MRI for the early detection of SBO in the case of COM accompanying with the greater risk of infection developments such as diabetes.

Analysis of Differences between the Sonic Layer Depth and the Mixed Layer Depth in the East Sea (동해의 음향층심도와 혼합층깊이 차이 분석)

  • Lim, Sehan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.5
    • /
    • pp.1259-1268
    • /
    • 2015
  • The sonic layer depth (SLD) variability is important for understanding the acoustic properties of the upper ocean that influence acoustic communications, acoustic tomography, and naval operations related to searching and detecting marine underwater vessels. Generally, the SLD is the acoustical equivalent of the mixed layer depth (MLD), although they are defined differently. In this study the SLD was compared with the MLD over the annual cycle in the East Sea using an available set of temperature-salinity observation profiles. For the comparison, various definitions and methods of the MLD had applied. As a result, the SLD in the East Sea is slight similar to the curvature method applied MLD, but the other MLD have severe differences with the SLD. Futhermore, a parabolic equation transmission model is used to evaluate the cutoff frequency trapped in surface duct. It follow that there is an optimum frequency for propagation at which the loss of sound is minimum.

A study of DDS Middleware based Multimedia PACS Data Transmission Scheme for QoS in Hospital Network (병원 전산망에서 QoS보장을 위한 DDS 미들웨어 기반 멀티미디어 PACS 데이터 전송 기법 연구)

  • Kim, Nam-Ho;Seung, Teak-Young;Lee, Suk-Hwan;Lee, Jong-Keuk;Kwon, Ki-Ryong
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2012.05a
    • /
    • pp.462-463
    • /
    • 2012
  • 팍스시스템은 의료 영상을 디지탈화한 시스템이다. PACS데이터는 초창기 CR(Computed Radiography)의 경우 10MB내외의 데이터를 발생하였으나 의료장비의 발전으로 인해 DB(Digital Radiography)는 20MB이상의 데이터를 발생하였다. 또 CT(Computed Tomography)의 경우 0.5MB데이터를 100Slice내외의 데이터를 발생하였으나, 현재는 Cardiac/PET 등의 CT는 Multi Frame을 지원하며 300~5000Slice이상의 데이터를 발생하게 됨에 따라 네트워크에 상당한 트래픽이 발생하여 병원 진료 환경에 심각한 영향을 초래한다. 또한, 스마트 폰, 태블릿 pc등의 발전으로 인해 많은 사용자들은 실시간 또는 멀티미디어와 같은 데이터 표현 방식으로 팍스 데이터를 보길 원할 것이며, 팍스 시스템 또한 그러한 요구조건을 만족시키기 위해 발전하고 있다. 병원에서 사용하는 네트워크는 인터넷 서비스의 모토인 best effort방법을 일반적으로 사용한다. 이러한 데이터 전송방식은 진료에 직접적인 영향을 미치는 팍스 데이터의 전송에 영향을 미칠 수 있다. 특히 네트워크의 트래픽이 제한적인 환경에서 높은 대역폭을 요구하는 멀티미디어 팍스 데이터를 다수의 사용자들이 전송받기 원하면 지연시간으로 인해 원활한 진료진행을 방해 받을 수 있다. 이러한 문제를 해결하기 위해 네트워크 개발자들은 QoS라는 개념을 도입하였고, 여러 계층에서 QoS를 보장하기 위한 연구가 진행되였다. 일반적으로, 네트워크에서 QoS를 지원하기 위한 여러가지 형태의 연구들을 조사하고, 분산 시스템을 제어하기 위한 DDS 미들웨어에 대한 연구를 기반으로 병원 네트워크에서 적용 방안을 설계하고 시뮬레이션을 통해 검증함으로써 새로운 형태의 병원 네트워크를 제안하고자 한다.

  • PDF