• Title/Summary/Keyword: Transmission Suspension Insulator

Search Result 32, Processing Time 0.022 seconds

Accelerating Aging of Transmission Line Porcelain Suspension Insulators by Autoclaving

  • Lee, Won-Kyo;Choi, In-Hyuk;Shin, Koo-Yong;Hwang, Kab-Cheol;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.147-150
    • /
    • 2008
  • Porcelain suspension insulators aged for 1, 5 and 10 years on Korean transmission lines and new insulators are tested for autoclave expansion. The compressive strength of the insulators aged in an autoclave with conditions of $250\;^{\circ}C$ and at 20 atm for 30 minutes, was about $7.6\;kgf/mm^2$, which is close to that measured on insulators aged for 10 years in the field. From simulation results, the cement displacement changed linearly with temperature. At a temperature of $200\;^{\circ}C$, the shear stress was approximately $7\;kgf/mm^2$; a stress that is brought about by a 0.07 % expansion of the cement. It is evident that the cement would fracture at a 0.07 % expansion, because the cement has about 7 to $9\;kgf/mm^2$ flexure strength. A turning point in the shear stress with mechanical load occurred at 0.02 % cement expansion. From an analysis of the porcelain body it is shown that there is sufficient margin of strength to guard against fracture of the porcelain body even for a cement expansion more than 0.12 %.

Study on Performance and Aging Test of Porcelain Insulators for Transmission Line (송전용 자기재 애자의 성능평가 및 가속열화시험)

  • 한세원;조한구;박기호;이동일;최인혁
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.9
    • /
    • pp.842-850
    • /
    • 2003
  • The suspension insulators are subjected to harsh environments in service for a long time. The long-term reliability of tile insulators is required for both mechanical and electrical performances. This study describes some basic performance tests and accelerated aging test by cool-heat cycling methods and thermal mechanical performance test methods on alumina porcelain insulators (new and aged) used for transmission line in KOREA. There was no fail in electrical and mechanical performance tests such as a high voltage strength, a flashover voltage, and an impact strength in all samples. But in the case of accelerating aging tests which have above 9$0^{\circ}C$ temperature gradient, fracture phenomena was happened by a thermal shock in tile aged sample(sample A) with low alumina porcelain body. It was indicated that sample A was more severely aged than other samples. According to results of HRB test and microstructural analysis, it was reasoned that insulator bodies with the matrix reinforced with alumina crystalline phase have advantages over the suppression of crack advance. And cool-heat aging and mechanical thermal ageing tests shows that a temperature gradient is more effective to accelerating than a cycling number.

Development of Working Platform for the Polymer Insulator String (송전선로 폴리머애자 공사용 장비 개발)

  • Min, Byeong-Wook;Wi, Shwa-Bok;Bang, Hang-Kwon;Choi, Han-Yeol;Baek, Soo-Gon;Park, Jae-Ung
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.438-439
    • /
    • 2006
  • Porcelain insulators have generally been used in Korea to insulate a transmission line from the tower, and a highly polymerized compound polymer insulator which has superior stain proof characteristics, has also been used widely. Currently, a worker rides on the suspension insulator string for installation on towers and conductors but in case of polymer insulators, this will pollute and scratch the housing result in durability reduction by deterioration and corona. This study developed a high strength aluminum compound metal lauder designed to work on polymer insulators without riding, and a clamp type connecting device and safety gear for easy installation on the tower and conductor. These polymer insulator work device can be used for 154kV and 345kV polymer insulators through a strength and load test to secure safety. This paper presents field usage.

  • PDF

A Study on Characteristics of Suspension Insulator for 400kN Transmission Lines (400kN 송전용 현수애자의 특성연구)

  • Choi, I.H.;Shin, T.W.;Choi, Y.G.;Min, B.W.;Lee, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1434-1436
    • /
    • 2002
  • The 400KN suspended insulator was fabricated with feldspar, quartz, clay and $Al_2O_3$ wt% for extra high voltage. These materials were grinded with ball milling for 25 hours after mixing them. The grinded materials were sintered at $1300^{\circ}C$ for 50 minutes in the tunnel kiln after mading with jiggering method. The sintered density of specimen was reached at 97% in comparison with that of theory. The specimen had the characteristic of temperature rise with the increase of electrical losses. Also, the flexural strength and the fracture toughness of sintered parts respectively were 1658 kg/$cm^2$ and 2.3 $MPa{\cdot}m^{1/2}$.

  • PDF

Study according to additional Alumina of Porcelain Insulator for T/L (송전용 자기재 애자의 알루미나 함유량에 따른 특성 연구)

  • Choi, I.N.;Choi, J.H.;Sin, T.W.;Lee, D.L.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.65-68
    • /
    • 2005
  • 알루미나 함유량의 변화에 따른 국산 2001년, 2004년 애자와 외국산 2000년도 36,000lbs 불소켓형 현수애자에 대해 물성 분석을 실시하였다. 그 결과 2001년도 자기애자의 알루미나 함유량을 17%로 하고 2004년도 알루미나 함유량이 20%로 하였을 경우 자기 애자의 기계적 특성은 10% 정도 향상되었다. 그리고 2001년도에 제조한 애자의 자기 상대밀도는 이론밀도의 96%에 도달하였으나 2004년도에 제조한 애자의 상대 밀도는 이론민도의 98%에 도달하였으면 애자의 균일성을 나타내는 Qs 값은 5.01로 높게 나타났다.

  • PDF

Thermal Impact Characteristics by Forest Fire on Porcelain Insulators for Transmission Lines

  • Lee, Won-Kyo;Choi, In-Hyuk;Choi, Jong-Kee;Hwang, Kab-Cheol;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.143-146
    • /
    • 2008
  • In this study the thermal impact characteristics by forest fire are extensively investigated using temperature controlled ovens. The test conditions for thermal impact damage are simulated according to the characteristics of natural forest fire. The test pieces are suspension porcelain insulators made by KRI in 2005 for transmission lines. In the thermal impact cycle tests with $300\;^{\circ}C$ thermal impact gradient (-70 to $230\;^{\circ}C$), cycling in 10 minute periods, no critical failures occurred in the test samples even with long cycle times. But in tests with thermal impact gradient from room temperature to $200-600\;^{\circ}C$, cycling in 10 to 30 minute periods, there were critical failures of the porcelain insulators according to the thermal impact gradient and quenching method. In the case of thermal impact by forest fire, it was found of that duration time is more important than the cycling time, and the initiation temperature of porcelain insulator failures is about $300\;^{\circ}C$, in the case of water quenching, many cracks and fracture of the porcelain occurred. It was found that the thermal impact failure is closely related to the displacement in the cement by thermal stress as confirmed by simulation. It was estimated that the initiation displacement by the thermal impact of $300\;^{\circ}C$ is about 0.1 %. Above 1% displacement, it is expected that the most porcelain insulators would fail.

The Temperature Distribution Analysis and Temperature Rise Test of Pole Mold Transformer (초고압 현수애자의 Pin 형상에 따른 응력해석)

  • Cho, Han-Goo;Park, Ki-Hoo;Han, Se-Won;Yun, Mun-Su
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.155-157
    • /
    • 2001
  • Various types suspension insulators made of toughness glass or porcelain are used in the power transmission. And, Insulators are continually subject to mechanical and electrical stresses which depend on the characteristics of the line. The main factor that influence the increase in reliability of insulators. In operation is the capacity of the design to withstand the certain load over a long time, the mechanical strength of the insulators. This paper describes the results of a study on the stress analysis of suspension insulator based on the finite element analysis using NASTRAN. And, the mechanical strength was evaluated through such as kinds of pin type.

  • PDF

A Characteristic Analysis of EHV Porcelain Insulators by Raw Materials (초고압 송전용 자기재 애자의 재질에 따른 특성 분석)

  • Choi, In-Hyuk;Choi, Jang-Hyun;Jung, Yoon-Hwan;Lee, Dong-Il;Jung, Gil-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.146-149
    • /
    • 2004
  • In order to analyze the physical and chemical characteristics of the home production porcelain insulators by change of the alumina addition amount, 36000lbs ball socket type suspension insulators which were manufactured in 1989, 1995 and 2001 removed in transmission line and an experiment was performed. By the result, 8 wt.% alumina that influences the mechanical properties and arc resistance properties in case of insulators that were manufactured in 1989 was contained. Amount of alumina was contained most by 17 wt.% in case of insulators that were manufactured in 2001.

  • PDF

A study on properties of 400kN porcelain suspension insulator for transmission line by analyzing of raw materials (400kN 송전용 자기애자의 재질에 따른 특성 연구)

  • Choi, In-Hyuk;Choi, Jang-Hyun;Jung, Yoon-Hwan;Lee, Dong-Il;Jung, Gil-Jo;Min, Byeong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1637-1639
    • /
    • 2004
  • In order to analyze the physical and chemical characteristics of the home production porcelain insulators by change of the alumina addition amount, 36000lbs ball socket type suspension insulators which were manufactured in 1989, 1995 and 2001 removed in transmission line and an experiment was performed. By the result, 8 [wt.%] alumina that influences the mechanical properties and arc resistance properties in case of insulators that were manufactured in 1989 was contained, and the relative density and the fracture toughness of insulators appeared by 94.2% and 1.4 [MPa $M^{1/2}$], respectively. However, 12 [wt.%] alumina was contained in case of insulators that were manufactured in 1995, and the relative density and the fracture toughness of insulators appeared preferably lower by 92% and 1.3 [MPa $M^{1/2}$], respectively. Amount of alumina was contained most by 17 [wt.%] in case of insulators that were manufactured in 2001. It was confirmed that the electrical and mechanical characteristics such as the relative density and the fracture toughness appeared excellently by 96% and 1.7 [MPa $m^{1/2}$], respectively.

  • PDF

A Study on the Properties of 36,000lb Porcelain Insulators by Contained Alumina of Raw Materials

  • Choi In-Hyuk;Choi Jang-Hyun;Jung Yoon-Hwan;Lee Dong-Il
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.1
    • /
    • pp.8-13
    • /
    • 2005
  • In order to analyze the properties of domestically produced 36,000lb porcelain insulators by change of the alumina addition to raw materials, 36000lb ball socket type suspension insulators that were manufactured in 1989, 1995 and 2001 were removed from transmission lines and an experiment was performed. The results indicated that 8 [wt.%] alumina, which influences the mechanical properties and arc resistance properties in the case of insulators that were manufactured in 1989 was contained, and the relative density and the fracture toughness of insulators appeared by 94.2% and 1.4 [MpaㆍM/sup 1/2/], respectively. However, 12 [wt.%] alumina was contained in the case of insulators that were manufactured in 1995, and the relative density and the fracture toughness of insulators appeared preferably lower by 92% and 1.3 [MpaㆍM/sup 1/2/], respectively. The greatest amount of alumina was contained by 17 [wt.%] in the case of insulators that were manufactured in 2001. It was confirmed that the electrical and mechanical characteristics such as the relative density and the fracture toughness appeared remarkably by 96% and 1.7 [Mpaㆍm/sup 1/2/], respectively.