• 제목/요약/키워드: Transmission Source

Search Result 1,266, Processing Time 0.045 seconds

Ship Radiated Noise Measurement Methods and Accuracy Analysis (선박 방사소음의 측정방법 및 정확도 해석)

  • Lee, Phil-Ho;Yoon, Jong-Rak
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.6 s.99
    • /
    • pp.738-748
    • /
    • 2005
  • The ship radiated noise level fluctuates by the difference of interference and reverberation according to measurement methods and environmental conditions. These phenomena cause error of the source level estimation even in the same environment conditions. This paper describes a quantitative analysis and a reduction method for an error value to the source level estimation in spatial and temporal interference environment. The design criteria of the radiated noise measurement array composed of omni-directional hydrophones and the source level accuracy in the deep water range are given. The source level accuracy in the shallow water range is also derived based on the statistical model of the multiple reflection paths. The results are verified using the water tank experiment and the sea trial.

Design of power amplifier and antenna for wireless power transmission (무선전력 송수신을 위한 전력용 증폭기와 송수신 Antenna 설계)

  • Yim, Sang-Wook;Kim, Yong-Sang;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.247-249
    • /
    • 2004
  • Electric systems can be classified into two classes on the basis of the location of its energy source. One system is to be connected with its outside energy source. Obviously, these electric system is limited of its motion range and impossible to operate in the situation without a way to find an energy source nearby. another is to posses the energy source within it. These electric systems are free of motion range limit while their using is limited by the life of source. These limits can be tided over by using passive-type RF communication. RF-ID is a system that Is possible to interchange electricity and data by Radio Frequency to locate and identify various objects including a man.

  • PDF

Transmission Path Analysis of Noise and Vibration in a Rotary Compressor by Statistical Energy Analysis

  • Hwang, Seon-Woong;Jeong, Weui-Bong;Yoo, Wan-Suk;Kim, Kyu-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.11
    • /
    • pp.1909-1915
    • /
    • 2004
  • The hermetic rotary compressor is one of the most important components of an air conditioning system since it has a great effect on both the performance and the noise and vibration of the system. Noise and vibration occurs due to gas pulsation during the compression process and to unbalanced dynamic force. In order to reduce noise and vibration, it is necessary to identify their sources and transmission path and effectively control them. Many approaches have been tried in order to identify the noise transmission path of a compressor. However, identification has proven to be difficult since the characteristics of compressor noise are complicated due to the interaction of the compressor parts and gas pulsation. In this study, the statistical energy analysis has been used to trace the energy flow in the compressor and to identify the transmission paths from the noise source to the exterior sound field.

The Development of New UPFG Steady-State Model using Transmission Line Constant G. B (UPFC가 계통에 미치는 영향을 선로정수 G, B의 함수로 표현한 새로운 UPFC 정태 해석모델 개발)

  • Jeon, D.H.;Kim, T.G.;Chu, J.B.;Kim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1167-1169
    • /
    • 1999
  • This paper presents the new unified power flow controller(UPFC) load flow algorithm using UPFC transmission line constant model. The UPFC transmission line constant model represents a function of transmission line constant(G.B) UPFC's effect in power system. It can easily be incorporated in a load flow program. The algorithm is suited for monitoring the power system state as well as determining the magnitude and Phase angle of UPFC serial voltage source.

  • PDF

A Study on the Improvement of Reverberation Room's Performance (잔향실 성능 검증 및 향상 연구)

  • Kim, Sung-Hoon;Joo, Won-Ho;Kim, Dong-Hae;Bae, Jong-Guk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.171-175
    • /
    • 2006
  • Recently, two reverberation rooms were built up of 300mm thick concrete walls in non-parallel pentagonal shape to measure the sound absorption, transmission, radiation, and impact insulation of acoustical materials, panels, doors, etc. Various acoustic tests, including the sound transmission test, were carried out to investigate their acoustic performances. In order to improve the performance, several modifications on these acoustical parameters, such as the acoustic mode, the position of specimen, the formation of diffuse field, the location of sound source, and flanking transmission, have been conducted. Through a series of tests, the reverberation rooms have been effectively improved so that it could perform a variety of acoustic tests with the international standard. And then, it is expected to be very helpful in developing the low noise design technology for ships.

  • PDF

Adaptive Temporal Rate Control of Video Objects for Scalable Transmission

  • Chang, Hee-Dong;Lim, Young-Kwon;Lee, Myoung-Ho;Ahan, Chieteuk
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1997.06a
    • /
    • pp.43-48
    • /
    • 1997
  • The video transmission for real-time viewing over the Internet is a core operation for the multimedia services. However, its realization is very difficult because the Internet has two major problems, namely, very narrow endpoint-bandwidth and the network jitter. We already proposed a scalable video transmission method in [8] which used MPEG-4 video VM(Verification Model) 2.0[3] for very low bit rate coding and an adaptive temporal rate control of video objects to overcome the network jitter problem. In this paper, we present the improved adaptive temporal rate control scheme for the scalable transmission. Experimental results for three test video sequences show that the adaptive temporal rate control can transfer the video bitstream at source frame rate under variable network condition.

  • PDF

Outage Analysis of Cooperative Transmission in Two-Dimensional Random Networks over Rayleigh Fading Channels

  • Tran, Trung Duy;Kong, Hyung-Yun
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.4
    • /
    • pp.262-268
    • /
    • 2011
  • In this paper, we evaluate the outage performance of cooperative transmission in two-dimensional random networks. Firstly, we derive the joint distributions of the source-relay and the relay-destination links. Secondly, the outage probability for the decode-and-forward relaying system is derived when selection combining (SC) is employed at the destination. Finally, we calculate the average outage probability of the system and then attempt to express it by a simple approximate expression. The simulation results are presented to verify the accuracy of the derivations. Similar to deterministic networks, the cooperative transmission in random networks outperforms direct transmission at a high signal-to-noise ratio (SNR).

Development of Automatic Program for Noise Inspection of Auto-transmission (자동변속기(Auto-Transmission)의 이상음 검사자동화 시스템개발)

  • 김재열
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.6
    • /
    • pp.9-18
    • /
    • 2000
  • This study includes noise automatic inspection system for washing machine auto-transmission one of modern home necessary. We effort to find and certificate sound noise source by sound power and sound intensity, and apply to frequency analysis in vibration related sound noise. still more we have been studying to data acquisition and programming for MS VisualBasic version 5.0. System component is below. 1) Pentium PC or data acquisition. 2) DSO for noise acquisition. 3)S/W for comparison and decision. 4) I/F Board for data communication. Wave form data through the DSO are converting to ASCII code data. The ASCII code through binary converting S/W. Finally we will making noise monitoring system and automatic inspection system.

  • PDF

Dual-Hop Amplify-and-Forward Multi-Relay Maximum Ratio Transmission

  • Erdogan, Eylem;Gucluoglu, Tansal
    • Journal of Communications and Networks
    • /
    • v.18 no.1
    • /
    • pp.19-26
    • /
    • 2016
  • In this paper, the performance of dual-hop multi-relay maximum ratio transmission (MRT) over Rayleigh flat fading channels is studied with both conventional (all relays participate the transmission) and opportunistic (best relay is selected to maximize the received signal-to-noise ratio (SNR)) relaying. Performance analysis starts with the derivation of the probability density function, cumulative distribution function and moment generating function of the SNR. Then, both approximate and asymptotic expressions of symbol error rate (SER) and outage probability are derived for arbitrary numbers of antennas and relays. With the help of asymptotic SER and outage probability, diversity and array gains are obtained. In addition, impact of imperfect channel estimations is investigated and optimum power allocation factors for source and relay are calculated. Our analytical findings are validated by numerical examples which indicate that multi-relay MRT can be a low complexity and reliable option in cooperative networks.

Transmission Dose Measurement of Gamma-ray Using Tungsten Shield (텅스텐 차폐체의 감마선 투과선량 측정)

  • Han, Sang-Hyun;Koo, Bon-Yeoul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.124-129
    • /
    • 2018
  • This study was conducted to investigate the penetration dose and shielding rates of tungsten shields used in apron material by changing the type of source used in the nuclear medicine department, thickness of shielding material and distance between the source and detector. For the experiment, the source, shield, and detector were arranged in a straight line and measured with an inspector at a height of 100 cm. The highest shielding effect of tungsten was measured for $^{201}Tl$, while $^{123}I$ showed a higher shielding effect than $^{99m}Tc$. For the sources used in the experiment, the penetration dose decreased with distance and the shielding rate was measured with thicker thickness. However, the shielding rate of $^{13}1I$ and $^{18}F$ sources was found to be lower than when there was no shielding at 0.25 mmPb shield. Therefore, even if the radiation shielding effect of tungsten is high, considering the characteristics according to the type of source and the thickness of the shielding material, it may be helpful to reduce the exposure.