• Title/Summary/Keyword: Transmission Performance Evaluation

Search Result 673, Processing Time 0.033 seconds

Evaluation of the Sound Transmission Loss of a Light Weight Honeycomb Structure (정량구조물의 차음성능 향상방안 : ″Honeycomb 구조의 적용사례″)

  • 김운경;김정태;김석현
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.446-451
    • /
    • 2002
  • Honeycomb structures have advantages in weight reduction with stiffness increment. As far as noise is concerned, however a light aluminum structure, instead of a steel frame, should have an equivalent mass density in order to maintain sound insulation performance. In this paper, an evaluation of a material effect on noise has been examined.

  • PDF

Link Quality Estimation in Static Wireless Networks with High Traffic Load

  • Tran, Anh Tai;Mai, Dinh Duong;Kim, Myung Kyun
    • Journal of Communications and Networks
    • /
    • v.17 no.4
    • /
    • pp.370-383
    • /
    • 2015
  • Effective link quality estimation is a vital issue for reliable routing in wireless networks. This paper studies the performance of expected transmission count (ETX) under different traffic loads. Although ETX shows good performance under light load, its performance gets significantly worse when the traffic load is high. A broadcast packet storm due to new route discoveries severely affects the link ETX values under high traffic load, which makes it difficult to find a good path. This paper presents the design and implementation of a variation of ETX called high load - ETX (HETX), which reduces the impact of route request broadcast packets to link metric values under high load. We also propose a reliable routing protocol using link quality metrics, which is called link quality distance vector (LQDV). We conducted the evaluation of the performance of three metrics - HETX, ETX and minimum hop-count. The simulation results show that HETX improves the average route throughput by up to 25% over ETX under high traffic load. Minimum hop-count has poor performance compared with both HETX and ETX at all of the different traffic loads. Under light load, HETX and ETX show the same performance.

Performance Evaluation of ECG Compression Algorithms using Classification of Signals based PQSRT Wave Features (PQRST파 특징 기반 신호의 분류를 이용한 심전도 압축 알고리즘 성능 평가)

  • Koo, Jung-Joo;Choi, Goang-Seog
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4C
    • /
    • pp.313-320
    • /
    • 2012
  • An ECG(Electrocardiogram) compression can increase the processing speed of system as well as reduce amount of signal transmission and data storage of long-term records. Whereas conventional performance evaluations of loss or lossless compression algorithms measure PRD(Percent RMS Difference) and CR(Compression Ratio) in the viewpoint of engineers, this paper focused on the performance evaluations of compression algorithms in the viewpoint of diagnostician who diagnosis ECG. Generally, for not effecting the diagnosis in the ECG compression, the position, length, amplitude and waveform of the restored signal of PQRST wave should not be damaged. AZTEC, a typical ECG compression algorithm, is validated its effectiveness in conventional performance evaluation. In this paper, we propose novel performance evaluation of AZTEC in the viewpoint of diagnostician.

Development and Performance Evaluation Results of Remote Control Systems for Maritime Autonomous Surface Ships (자율운항선박의 원격제어 시스템 개발과 성능평가 결과)

  • Hong-Jin Kim;Hwa-Sop Roh;Jeong-Bin Yim
    • Journal of Navigation and Port Research
    • /
    • v.48 no.4
    • /
    • pp.335-341
    • /
    • 2024
  • Recently, research, development, and commercialization of maritime autonomous surface ships (MASS) and remote control are in progress. Remote control is intended to secure autonomous navigation environments for existing ships or early-stage MASS using a remote control system (RCS). The main function of an RCS is to control MASS using data transmission between the MASS and the remote control centre. Remote control by a remote control officer also has an important function. The purpose of this study was to develop RCS and a performance evaluation technique for operation data provided by the RCS. The experiment was conducted during the navigation period of a training ship 'Hannara' after building experimental equipment at both an onshore remote control center and a training ship. As a result of evaluating data transmitted and received using the developed RCS, it was confirmed that data transmission was possible within an error range of 0.1%p. Fourteen types of ship information reflecting the navigation environment of the training ship were confirmed to be transmitted and received. The RCS developed in this work complies with the three principles of remote control: safety, reliability, and availability. This study provides a core technology for the development of RCSs for MASS and the evaluation of data transmission performance.

Performance Evaluation of Routing Algorithms based on Optimum Transmission Range in Tactical MANETs (전술 MANET의 최적통달거리 기반 라우팅 알고리즘 성능 연구)

  • Choi, Hyungseok;Lee, JaeYong;Kim, ByungChul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.10-17
    • /
    • 2014
  • This paper presents an analytical method for finding the optimum transmission range in mobile ad hoc networks(MANETs). The results are particularly useful for the operation of military networks, as the transmission range affects the traffic throughput of user & routing traffic, delay, and frequency interference. When the conditions of tactical environment are applied in our simulations and the above-mentioned performances are analyzed, we find the OLSR protocol is more excellent. Plus, we compare the results of MANETs performance when applying optimum transmission range and the default transmission range(10km), and analyze the reasonability of the calculation of optimum transmission range proposed by this paper.

Transmission Performance Evaluation of Hybrid Lines Composed of SMF and MMP for FTTx Systems (단일 모드 광섬유와 다중 모드 광섬유 혼합 라인으로 구성된 FTTx 시스템의 전송 성능 평가)

  • Park, Seung-Hyeon;Kim, Kyong-Hon;Lee, El-Hang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.7A
    • /
    • pp.535-541
    • /
    • 2005
  • This paper proposes a hybrid optical lines composed of single-mode fiber(SMF) and multi-mode fiber(MMF) for gigabit-capable Passive Optical Network(GPON) using a WDM method with a single light source per each channel, and reports the results of transmission performance the proposed lines. The transmission link uses a direct modulated DFB-LD for high speed downstreams at the optical line terminal(OLT) of central office(CO) and a low cost SFP type transceiver for low-speed upstream in optical network unit(ONU). To split or combine the transmission channels, wavelength MUX/DEMUX are used in the optical line section, and MMFs not longer than 1 km are attached to the SMF lines at the ONU side of the WDM-PON links. We have performed the transmission experiment on the downstream of 2.5 Gbit/s, and 1.25 Gbit/s, and the upstream of 1.25 Gbit/s, and 622 Mbit/s which are recommended by ITU-T G.984.2. The transmission margin and feasibility of the proposed links have been tested to be suitable up to 2.5 Gbit/s transmission.

A Current State of Multihousing Evaluation Based on the Construction Criteria and Performance Codes of Green Homes (친환경주택의 건설기준 및 성능규정에 의한 공동주택 평가현황에 관한 연구)

  • Lee, Seul-Bi;Yu, Ki-Hyung;Yoon, Seong-Hoon
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.113-118
    • /
    • 2015
  • Purpose: In Korea, buildings make up 20.5% (2012) of the gross national energy consumption, so they are a major target for greenhouse gas reduction. In particular, energy consumption in multihousing represents approximately 32.6% of the entire building sector. With improving energy performance being the focus, efforts are continuously being made to reinforce standards and systems in greenhouse gas reduction. This study investigated the current status of multihousing in Korea in terms of energy performance as described in the performance evaluation reports submitted (to an institution that specializes in reviewing the performance evaluation of green homes) based on the construction criteria and performance codes for green homes and examined if the evaluation criteria using related methodologies were appropriate. The results will provide helpful information for reviewing the future directions of operations and amendments to the systems. Method: The overall characteristics of the system were examined using the evaluation methodologies (and current state of revisions) of the performance codes for green homes and comparing them with similar systems. Also, the current state of application and energy performance (conducted according to the evaluation methodologies) were compared by the evaluation institution for multihousing neighborhoods that were assessed for five years from 2010 to 2014. Result: It has been confirmed that the performance codes for green homes are different from other similar systems in evaluating performances of multihousing in that they allow both quantitative and qualitative methods of evaluation, and they consider both energy and sustainability simultaneously in the evaluation. Furthermore, regarding the adoption rate of the forms for the two evaluation methods (Form 1 - quantitative and Form 2 - qualitative), the rate preferring Form 2 increased gradually in time to reach 55.3% in 2014. In analyzing the rate of overall energy reduction (submitted in Form 1) and the coefficient of thermal transmission for each part (submitted in Form 2), it was observed that the deviation between the performance submitted and the criteria decreased in line with the level of reinforcement.

Thermal Performance Evaluation of The Window Film Insulation for Building Energy Savings (건물에너지 절감을 위한 열차단 필름의 성능 평가)

  • Nam, Jung-Woo;Won, Jong-Seo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.75-80
    • /
    • 2008
  • Recently, Energy savings in buildings has received much attention in response to the increased needs for global warming and better comforts of the occupants in apartment housing. This study proposes the method which uses the sun control window film to reduce the cooling load and heating load improving the thermal performance of the building and it improves an energy efficiency. The film which used in actual measurement has a low shading coefficient and a solar energy transmission. so we measured the surface temperature of the triple Low-e glazing system used and inside temperature according to the change of outside temperature and solar energy to study thermal performance evaluation. As a result, it was helpful to use window film insulation to reduce inside temperature in summer and to keep room warm in winter.

  • PDF

Effects of Forwarders on TCP Performance in Network Coding for Wireless Mesh Networks (무선 메쉬 네트워크의 네트워크 코딩에서 패킷 전달자들이 TCP 성능에 미치는 영향)

  • Lim, Chan-Sook;Ahn, Hong-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.6
    • /
    • pp.39-45
    • /
    • 2010
  • Most traffic in the real internet is TCP traffic. Therefore newly proposed network coding schemes must consider their effects on TCP performance. However, in most studies on network coding, performance evaluation has been conducted using other types of traffic than TCP traffic because network coding has effects on the pattern of packet transmission, which again can impact TCP performance. In most packet transmission schemes based on network coding for wireless mesh networks, it is determined which node, among the ones that received a broadcasted packet, should encode and forward it. In this paper, we examine how the forwarder nodes impact TCP performance.