• 제목/요약/키워드: Transmission Line Method

검색결과 1,065건 처리시간 0.031초

UHF센서를 이용한 가스절연송전선로 절연파괴 위치 추정에 관한 연구 (A Study on Estimation of Breakdown Location using UHF Sensors for Gas Insulated Transmission Lines)

  • 박흥석;한상옥
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.805-810
    • /
    • 2011
  • This paper deals with the method and algorithm used to find fault locations in gas insulated transmission line. The method uses UHF sensors and digital oscilloscope to detect discharge signals emitted to the outside through insulating spacer in the event of breakdown inside GIL. UHF sensors are the external type and installed at outside of insulating spacers of GIL. And we used wavelet signal processing to analyze the discharge signals and confirm the exact fault location findings in the GIL test line. This method can overcome demerit of TDR(Time Domain Reflectometer) method having been applied to detect fault location for conventional underground transmission lines, and Ground Fault Sensors used in conventional GIS systems. TDR method requires high level of specialty and experience in analyzing the measured signals. Ground fault sensors are installed inside GIL and can be destroyed by high transient voltage. This paper's method can simplify the fault location process and minimize the damage of sensors. In addition, this method can estimate the fault location only by the time difference when discharge signals are arrived to detecting sensors at the ends of GIL sections without reasons of breakdown. To test the performance of our method, we installed sensors at the ends of test line of GIL(84m) and sensed discharge signals occurred in GIL, energized with AC voltage generator up to 700kV.

항만운영정보시스템의 데이터전송방식 개선에 관한 연구 (A Study on the Improvement of Data Transmission Method of PORT-MIS)

  • 김칠호;박남규;최형림
    • 한국항만학회지
    • /
    • 제14권2호
    • /
    • pp.133-142
    • /
    • 2000
  • In order to streamline the procedure of data transmission in port and logistics industries, MOMAF introduced EDI systems as the method of data transmission of 19 documents 5 years ago. While operating EDI system, MOMAF has found the inconvenience and the inefficiency of using EDI systems in the field of requesting fast response. This thesis focuses on finding the possible fields of on-line processing system. The result of the paper presents that if data transmission area such as 'application for pilot'is changed to on-line processing method, the processing cost and time will be reduced compared with EDI processing method.

  • PDF

철도 사고현장의 효율적인 동영상 전송 방안에 관한 연구 (A study on effective sending of moving picture from train accident site)

  • 조봉관;장석각
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.289-291
    • /
    • 2003
  • Railway takes an important role of transporting massive passenger and freight. Accidents which occur related to trains have a risk of serious loss of lives, so those accidents need to be controlled urgently Therefore moving picture transmission system is required which transmits exact information of moving picture of accident status to CTC and also communication line is also required with it. By using WTB line as a wayside transmission line, railway telephones, fax and train service information are provided to local offices. As transmission line improving project, optical cabling work is being processed by phases. Therefore optical fiber line is more effective way for a communicating way between stations than coaxial transmission line. This Paper considers connecting method when optical fibers is used for moving picture data transmission of train accidents and its problems.

  • PDF

가공송전선의 송전용량을 증가시키기 위한 동적송전용량 시스템의 설계 (A Design for Dynamic Line Rating System to increase Overhead Transmission Line Capacities)

  • 김성덕
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.72-77
    • /
    • 2011
  • Dynamic Line Rating (DLR) techniques have been greatly worthy of notice for efficiently increasing transmission capacity as well as controlling load-flow in overhead transmission lines, in comparison with the existing power system operating with Static Line Rating (SLR). This paper describes an utilization method to implement DLR control system for old transmission lines built in the first stage using the ground clearance design standard with lower dips. The suggested DLR system is focused on designing as temperature control system rather than current/load control system. Based on several performance for conductor temperatures, it is shown that DLR system with efficiency can be implemented.

영상-모드 및 Galerkin법을 이용한 전송선 문제 해석 (An Analysis of Transmission Line Structure by Combining Image Mode and Galerkin Methods)

  • 신규현;정현교;한송엽
    • 대한전기학회논문지
    • /
    • 제40권12호
    • /
    • pp.1296-1301
    • /
    • 1991
  • This paper presents a hybrid image mode Galerkin method for the analysis of the transmission line structures suspended between infinite parallel ground planes. A Green's function that consists of numerically accelerated image mode terms is developed, which is used in boundary integral equation. Transmission lines of arbitrary cross section are analyzed using Galerkin's method. Two kinds of configurations of transmission lines are studied in sample problems.

  • PDF

Open-Short 방식의 임피던스 측정에 의한 분포정수의 보정 (A LOSSY LINE DISTRIBUTED PARAMETERS CALCULATION USING DATA OF OPEN-SHORT IMPEDANCE MEASURING METHOD)

  • ;조기연;변영복;서정일;김은수;김태진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2553-2555
    • /
    • 1999
  • The paper contains design formulas and an execution algorithm for calculation of distributed parameters as well as wave and impedance parameters of a uniform transmission line using data of the line input impedance measurements by the OPEN-SHORT method. In difference from published before works on the OPEN-SHORT method application for line parameters determination, in which the lines with small losses are considered /1-3/, the obtained formulas allow to calculate parameters of transmission lines with arbitrary losses. It opens new possibilities of the OPEN-SHORT method utilization for development and application of the probe - type lossy dielectric media parameters meters based on transmission lines, including probe-type moisture material meters.

  • PDF

확장된 TRL 오차 수정 방법 (An Extended TRL Calibration Method)

  • 김유신;이창석
    • 한국전자파학회논문지
    • /
    • 제16권11호
    • /
    • pp.1099-1105
    • /
    • 2005
  • TRL 오차 수정 방법은 PCB 위에 제작된 고주파 소자를 측정할 때 많이 사용되는 방법이지만 오차 수정을 위해 제작된 표준 전송선 패턴의 특성 임피던스를 알아야만 보다 정확하게 측정 오차를 수정할 수 있다. 기존의 방법에서는 저항을 종단 처리한 표준 패턴을 추가로 이용하여 전송선의 단위 길이당 커패시턴스를 계산하고 주파수에 대해 fitting하는 방법으로 표준 전송선의 특성 임피던스를 계산하고 있으나 제작상의 부정확성에 의해 추출된 특성 임피던스가 영향을 받고 있음을 확인하였다. 본 논문에서는 측정된 S-parameter를 이용하여 제작상의 부정확성을 줄일 수 있고 기존 방법보다 정확한 특성 임피던스를 추출할 수 있다.

Chain Matrix를 이용한 Twisted Cable의 EMP(Electromagnetic Pulse) 결합 해석 (Analysis of Electromagnetic Pulse Coupling to Twisted Cable Using Chain Matrix)

  • 조제훈;이진호;김형동
    • 한국전자파학회논문지
    • /
    • 제21권7호
    • /
    • pp.734-743
    • /
    • 2010
  • 본 논문은 다중 도체 전송선 해석법과 chain matrix 알고리즘을 이용하여 twisted cable과 같은 비균일 전송선의 EMP 결합을 해석하였다. 전송선의 EMP 결합 해석을 위해 BLT(Baum-Liu-Tesche) 해석법이 널리 사용되고 있으나, twisted cable과 같은 비균일 전송선에 기존의 BLT 해석법을 바로 적용하기는 어렵다. Twisted cable과 같은 비균일 전송선을 해석하기 위해 수많은 작은 길이의 균일 전송선으로 나누어 모델링하였으며, 전체 비균일 전송선의 결합 특성은 각각의 균일 전송선의 EMP 결합 분석을 통해 최종적인 전송선의 결합 특성을 구함으로 써 가능해진다. 이러한 비균일 전송선 EMP 결합 해석 기법을 검증하기 위해 균일 전송선에 대하여 기존의 BLT 해석 결과와 비교하였으며, 제시된 비균일 전송선 EMP 결합 해석 기법을 지표면 위에 놓여 있는 twisted cable에 적용하여 대기 중의 핵폭발에 의한 HEMP(High altitude Electromagnetic Pulse)와 같은 매우 강한 펄스가 입사되었을 때, 전송선에 연결된 부하에 유기되는 전류(또는 전압) 응답을 분석하였다.

혼합송전선로 편단접지 구간 과전압 저감 방안에 관한 연구 (A Study on Overvoltage Reduction Method of Single Point Bonded Section on Combined Transmission Lines)

  • 정채균;강지원;박흥석;김진
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1881-1887
    • /
    • 2009
  • This paper discusses the effects of ECC (Earth Continuity Conductor) for reducing the level of induced sheath overvoltages at the single point bonded section of combined transmission lines which are mixed underground power cable with overhead line in one T/L. In previous papers, the characteristics of ECC on only underground power cable systems were sufficiently analyzed. However, the result of only underground power cable systems are totally different from that of combined transmission lines because ECC is commonly grounded with overhead grounding wire at mesh of cable head. Therefore, in this paper, the installation effects of ECC have been variously analyzed considering the three kinds of fault positions, cable formation of duct and trefoil, spacing between phase conductor and ECC, and the change of overhead transmission line section length on 154kV combined transmission line. Finally, simulation results show that ECC can effectively reduce the induced sheath voltage.

765kV 수직2회선 6도체 현수형 철탑에서 직접활선작업의 안전성 평가분석 (Analysis of Electrical Safety Level Test for Barehand Work at 765kV Vertical Double Circuit Six Bundle Conductors on the Suspension String Tower Type)

  • 김대식;한상옥
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.275-278
    • /
    • 2008
  • It has been issued that the necessity of Live line work for 765kV vertical double circuit six bundle conductors transmission line when the characteristics of transmission line, the composition of T/L and near the T/L circumstances etc. Others are considered. The Barehand method of UHV T/L is extremely dangerous work and especially it is directly related with lineman life so it is very dangerous. It should be performed several technology developments for live-line work on the UHV T/L, that should be considered such as the electrical influence on workers near the T/L, development of live-line facilities, guarantee of safety, the technical rules of live-line work, the safe method of live-line work and etc. In order to maintain the 765kV transmission lines safely by barehand work, first of all, we should know the analysis of electrical safety level test in live-line work at 765kV vertical double circuit six bundle conductors on the suspension string tower type.