• 제목/요약/키워드: Transmission Line Method

검색결과 1,066건 처리시간 0.041초

6도체 무볼트형 스페이서 댐퍼의 중량변화에 따른 진동현상 (Vibration Phenomenon with Weight Change of 6 Bundle Boltless Spacer Damper)

  • 김영달
    • 한국소음진동공학회논문집
    • /
    • 제13권9호
    • /
    • pp.671-678
    • /
    • 2003
  • Spacer dampers maintain the constant gaps between each conductor in a bundle conductor-transmission line, and are installed at proper intervals to keep a line from all sorts of damages derived from the vibration energy caused by mechanical or electrical external factors. It is most important to embody a technology which considers difficulties of maintenance and repair, and has optimum elements in order to prevent accidents such as destruction by fire or the snapping of a wire by the effect of vibration phenomenon coming from transmission line. In the present thesis, therefore, the analysis of vibratory characteristics of spacer damper is set up by analytical methods such as the analysis of conductor motion's governing equation, the equation of spacer damper's motion, spacer damper-fastened wire's motion in a span, and the numerical analysis of finite difference method. Furthermore, the installation distance between spacer dampers was scrutinized by simulations of various vibration phenomena which change at any time as actual conditions do, and hereafter we will be able to analyze all kinds of vibration phenomena coming from a boltless spacer damper with 6 bundle conductor for 765 k V transmission line based on new analytical methods.

송전선로 EMI 특성 실험용 인공잡음발생장치 설계, 제작 및 적용 (The Design, Manufacture and Applications of a Gap Noise Generator for Testing the Characteristics of EMI from Transmission Lines)

  • 주윤로;양광호;명성호;이동일;신구용
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권1호
    • /
    • pp.23-28
    • /
    • 2002
  • In order to survey the radiation characteristics of pure line noise of unwanted noise from overhead high voltage AC transmission lines, a disk type gap noise generator was manufactured. Disk size which decides capacitance between the noise generator and earth was selected through preliminary indoor experiments and analysis by using surface charge method. The capacitance is one of principal parameters related to the injection of a proper noise current into lines. On the basis of the capacitance obtained from calculation, 5mm of space was given to the gap of the noise generator to be installed o test line and an aluminum disk of 60cm radius was made. The field experiments were performed with the noise generator hung on the Kochang 765 kV full scale test line. As the results, the useful data which can be used to analysis the radiation characteristics of noise from transmission lines were obtained. Those are the directivity of antenna toward the line, lateral profiles, frequency spectra, height pattern and so on.

사고현장과 사령실간 화상전송기술에 관한 연구(II) (A study on the moving picture transmission method between the accident sites and control center(II))

  • 장석각;조봉관
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.653-658
    • /
    • 2003
  • This study is represented a method to give connect to optical cable from accident site and reviewed the method to transmission a moving image to control centre by real time, following the study of image transmission method in copper cable section where is a main line of railroad communication. Concept of network is studied to use cable and equipment effectively, and it's also reviewed technology of digital image transmission system and image evaluation methods, in spite of the pixel of camera and monitor resolution determine quality of image when moving image transferring by point to point. In addition, this study is reviewed checks and considerations of image transmission equipment (codec) with various transmission methods in room test, and then examined and analyzed wire/wireless combined transmission methods at wayside.

  • PDF

슬롯을 가진 삼각 패치형 인공 전송 선로 결합기 (A Slotted Triangular-Patch Type Artificial Transmission Line Coupler)

  • 오송이;황희용
    • 한국전자파학회논문지
    • /
    • 제22권5호
    • /
    • pp.510-515
    • /
    • 2011
  • 본 논문에서는 사각형 모양으로 공간 활용성이 높은 콤팩트한 구조를 갖는, 슬롯이 있는 삼각 패치형 인공전송 선로 결합기를 제안한다. 일반적인 결합기는 ${\lambda}$/4 길이의 전송 선로를 사용하기 때문에 소형화의 한계를 가지고 있으나, 이 구조는 ${\lambda}$/4보다 작은 길이일 때 결합기가 최대 결합도를 갖는 특징을 나타내어 소형화에 유리할 뿐만 아니라, 슬롯의 길이를 변화시킴으로써 설계상에 임피던스와 위상 조절에 용이하도록 하였다. 제시된 인공 전송 선로 결합기의 설계 방법을 바탕으로 중심 주파수 2.4 GHz에서 15 dB의 결합기를 시험 제작하여 제시된 방법의 유용성을 보였다.

가공송전선의 부하용량과 이도 특성에 관한 실험적 연구 (A An Experimental Study for Load Capacity and Dip Characteristic in Overhead Transmission Lines)

  • 김성덕
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.177-183
    • /
    • 2010
  • Overhead transmission lines in domestic area have been built by several different design standards of dip and ground clearance. This paper describes an experimental study for evaluating load capacity and dip margin in overhead transmission lines. Such design standards for selection of overhead transmission conductors, dip and ground clearance, as well as electrical equipment technical standard are discussed. Based on daily load and weather data, several characteristics such as line utilization factor, load factor, conductor temperature and dip, etc. are analyzed, and compared with the specified levels of design standards. As a result, it is verified that DLR method can be a clue of the solving of the problem, for occurring in old transmission conductors which may be rarely operating below standards.

송전선로 설계지원 프로그램의 활용에 대한 적용성 연구 - Optimal PowerLINE을 이용한 미얀마 500kV 송전선로 종단설계를 중심으로 - (A Practical Application Study on the Transmission Line Design S/W using Optimal PowerLINE - A Case Study on the 500kV Transmission Line Design in Myanmar Project -)

  • 윤영순;김태영;박찬형;조수영;박병원;이희선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.542-544
    • /
    • 2005
  • Recently, the principal processes of T/L design tend to computerize and therefore integrated T/L design system has been developed. Since, it makes the automatic selection of T/L route, tower position and optimum design possible, computerized design method is applied all over the world. KEPCO introduced Optimal PowerLINE for T/L design in Myanmar 500kV project that is as a part of overseas project. And as a result of that work, effective and economical design was carried out. This paper presents the comparative analysis between Previous method and Optimal PowerLINE method for investigating practical application to Myanmar 500kV T/L design.

  • PDF

부하의 전압특성을 고려한 3상 2회선 불평형 송전선로에서의 전자계에 대한 퍼지척도 가능성평가 (Assessment of Fuzzy Measure Possibility for the Electromagnetic Field of unbalanced two coupled Three-phase Transmission line Considering toad-Voltage Characteristics)

  • 송현선;김상철
    • 한국안전학회지
    • /
    • 제16권3호
    • /
    • pp.45-52
    • /
    • 2001
  • This paper presents a study on the assessment of fuzzy measure possibility for the electromagnetic field of unbalanced system. It takes into account m untransposed transmission line and unbalanced load. A three phase load flow program was developed which employs a Newton-Raphson method as a tool to analyze system unbalanced. This research presents a method of handling two coupled three phase transmission system unbalance analysis and unbalanced power demand as a function of voltages. In assessment of fuzzy measure possibility for the electromagnetic field, this paper use probability of fuzzy and measure of fuzziness technique.

  • PDF

On-Line Linear Combination of Classifiers Based on Incremental Information in Speaker Verification

  • Huenupan, Fernando;Yoma, Nestor Becerra;Garreton, Claudio;Molina, Carlos
    • ETRI Journal
    • /
    • 제32권3호
    • /
    • pp.395-405
    • /
    • 2010
  • A novel multiclassifier system (MCS) strategy is proposed and applied to a text-dependent speaker verification task. The presented scheme optimizes the linear combination of classifiers on an on-line basis. In contrast to ordinary MCS approaches, neither a priori distributions nor pre-tuned parameters are required. The idea is to improve the most accurate classifier by making use of the incremental information provided by the second classifier. The on-line multiclassifier optimization approach is applicable to any pattern recognition problem. The proposed method needs neither a priori distributions nor pre-estimated weights, and does not make use of any consideration about training/testing matching conditions. Results with Yoho database show that the presented approach can lead to reductions in equal error rate as high as 28%, when compared with the most accurate classifier, and 11% against a standard method for the optimization of linear combination of classifiers.

다단자 송전계통에서의 1선지락 고장시 고장점 표정 알고리즘 (A Fault Location Algorithm for a Single Line Ground Fault on a Multi-Terminal Transmission Line)

  • 강상희;노재근;권영진
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권2호
    • /
    • pp.121-133
    • /
    • 2003
  • This paper presents a fault location algorithm for a single phase-to-ground fault on 3-terminal transmission systems. The method uses only the local end voltage and current signals. Other currents used for the algorithm are estimated by current distribution factors and the local end current. Negative sequence current is used to remove the effect of load current. Five distance equations based on Kirchhoff's voltage law are established for the location algorithm which can be applied to a parallel transmission line having a teed circuit. Separating the real and imaginary parts of each distance equation, final nonlinear equations that are functions of the fault location can be obtained. The Newton-Raphson method is then applied to calculate the estimated fault location. Among the solutions, a correct fault distance is selected by the conditions of the existence of solution. With the results of extensive S/W and H/W simulation tests, it was verified that the proposed algorithm can estimate an accurate fault distance in a 154kV model system.

지중 송전선로 대칭분 임피던스 해석을 위한 EMTP 전후처리기 개발과 활용 (Development and Application of Pre/Post-processor to EMTP for Sequence Impedance Analysis of Underground Transmission Cables)

  • 최종기;장병태;안용호;최상규;이명희
    • 전기학회논문지
    • /
    • 제63권10호
    • /
    • pp.1364-1370
    • /
    • 2014
  • Power system fault analysis has been based on symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. Obtaining accurate line impedances as possible are very important for estimating fault current magnitude and setting distance relay accurately. Especially, accurate calculation of zero sequence impedance is important because most of transmission line faults are line-to-ground faults, not balanced three-phase fault. Since KEPCO has started measuring of transmission line impedance at 2005, it has been revealed that the measured and calculated line impedances are well agreed within reasonable accuracy. In case of underground transmission lines, however, large discrepancies in zero sequence impedance were observed occasionally. Since zero sequence impedance is an important input data for distance relay to locate faulted point correctly, it is urgently required to analyze, detect and consider countermeasures to the source of these discrepancies. In this paper, development of pre/post processor to ATP (Alternative Transient Program) version of EMTP (Electro-Magnetic Transient Program) for sequence impedance calculation was described. With the developed processor ATP-cable, effects of ground resistance and ECC (Earth Continuity Conductor) on sequence impedance were analyzed.