• 제목/요약/키워드: Transmission Line Method

검색결과 1,065건 처리시간 0.026초

송전선로 가선용 공중설치형 방호네트 및 설치공법 (Transmission-Line Wiring Midair Protection Net & Installation Methods)

  • 황치영;백병철;서민근;김영화;원재호
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1479-1484
    • /
    • 2011
  • The existing leg-rest for transmission line construction was established on the ground as a structure. As a result of that, it caused some problems such as, a tremendous forest damage, excessive construction costs and the long time of construction period. In order to solve these problems, we suggest the protective net for an air installation. It is a new method of construction which has a dielectric strength with a light-weight and high-strength. And it's not influenced by a geographical feature. This excellent method doesn't affect a forest and can reduce tremendously the construction cost and period.

등가 전력선을 가진 Chua 회로에서의 카오스 비밀통신 (Chaos Secure Communication using Chua Circuit with Equivalent Power Lines)

  • 배영철
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.263-266
    • /
    • 2000
  • In this paper, we formed a transmitter and receiver by using two identical Chua's circuits and then formed wireless transmission line from the channel which was between those two circuits. We proposed a secure communication method in which the desired information signal was synthesized with the chaos signal created in a Chua's circuit and sent to the transmitter through channel. Then the signal was demodulated receiver of Chua's circuit. The method we used to accomplish the sun communication was synthesizing the desired information with the chaos circuit by parallel connection in a wireless transmission line. After transmitting the synthesized signal to the wireless transmission line, we confirmed the actuality of the secure communication by separating the information signal and the chaos signal in the receiver. In order to confirm the security, we compared the wiretapped signal and the recovery signal under the assumption that the wiretapping had taken place. In order to separate the two signals, we transformed the information signal to a current source in the transmitter and detected the current in the receiver.

  • PDF

송전선로의 유효전력 손실을 각 부하에 배분하는 방법 (An Approach to Allocate Real Power Losses of Transmission Lines to Individual Loads)

  • 노경수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권1호
    • /
    • pp.13-18
    • /
    • 2000
  • The paper proposes a simple method to calculate the portion of real power losses of transmission lines allocated to individual loads. The method is implemented by defining loss distribution factors, and analyses the loads shares in the transmission line losses. The paper also performs calculation of sensitivities of the line losses with respect to load changes so as to be easily employed in on-line applications. Effectiveness of the algorithm is verified by computer simulations and it is estimated that the results can be used to compute the cost of one ancillary service under deregulated environment in electric power industries.

  • PDF

Chua 회로에서의 카오스 비밀통신 (Chaos Secure Communication Using Chua Circuit)

  • 배영철
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 춘계종합학술대회
    • /
    • pp.238-241
    • /
    • 2000
  • In this paper, we formed a transmitter and receiver by using two identical Chua's circuits and then formed wireless transmission line from the channel which was between those two circuits. We proposed a secure communication method in which the desired information signal was synthesized with the chaos signal created in a Chua's circuit and sent to the transmitter through channel. Then the signal was demodulated receiver of Chua's circuit. The Method we used to accomplish the secure communication was synthesizing the desired information with the chaos circuit by parallel connection in a wireless transmission line. After transmitting the synthesized signal to the wireless transmission line, we confirmed the actuality of the secure communication by separating the information signal and the chads signal in the receiver. In order to confirm the security, we compared the wiretapped signal and the recovery signal under the assumption that the wiretapping had taken place. In order to separate the two signals, we transformed the information signal to a current source in the transmitter and detected the current in the receiver.

  • PDF

765kV 교류 2회선 송전선 인근의 생체 및 물체 유도 전압, 전류 계산 (Calculation of the Induced Voltage and Current for a Human and an Object Close to 765kV AC Double Circuit Transmission Line)

  • 민석원;김응식;명성호;이병윤;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1509-1511
    • /
    • 1994
  • This paper calculates the induced voltage and current for a human and a car under 765 kV AC double circuit transmission line. A human and a car is simulated as two dimension by the use of charge simulation method and as three dimension by using surface charge method. The phase arrangement of transmission line is varied to calculate the induced voltage and current. In two cases a human and a car is grounded or floated, the induced voltage and current is also compared.

  • PDF

지역별 시송전선로 검토 및 검증방안에 관한 연구 (A study on the investigation and the verification method of the regional restorative transmission)

  • 이남호;송인준;조경보;곽노홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.187-189
    • /
    • 2003
  • Service restoration following a complete or partial collapse starts with reenergizing a transmission line from black-start generators. Voltage problems can arise from Ferranti effect as unloaded transmission line is reenergized and has to be required to consider it when KPX makes a restorative plan on the massive blackout. This paper presents the investigation of seven regional blackstart lines which are chosen by KPX restorative plan and suggests the verification method for the new designed line according to the system modification.

  • PDF

전력선 통신의 RF 유도형 결합기 해석 (Analysis of RF Inductive Couplers for Power Line Communication)

  • 노영석;이건복;박위상
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.85-91
    • /
    • 2015
  • 전력선 통신에서 사용되는 비접촉식 커플러의 신호 전달 특성을 향상시키기 위한 비접촉식 커플러의 구조와 자기장 결합에 대한 연구를 수행하였다. 비접촉식 커플러의 결합 구조를 분석하였고, Rogowski 코일을 이용한 커플러와 자성체 코어를 이용한 커플러를 제작하여 구조에 따른 신호 전달 특성을 분석하였다. 집중 정수 소자와 임피던스 트랜스포머를 이용한 임피던스 매칭법을 제안하여 협대역과 광대역에서 신호 전달 특성을 향상시켰고 전달 신호의 크기는 대역폭과 트레이드오프가 있음을 보였다. 본 연구는 추후 부하 변동에 따른 임피던스 매칭 연구에 도움을 줄 수 있다.

FDTD 수치해석에 의한 MIS transmission line의 전기적 특성 예측 (Prediction of Electrical Characteristics for MIS transmission line using FDTD Simulations)

  • 이준호;남승기;정지채
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(1)
    • /
    • pp.373-376
    • /
    • 2000
  • Coplanar-type MIS transmission lines have been simulated using FDTD method and compared with the measured results and the simulated results of the reference paper[3]. We can confirm that our simulation results are similar to measured results compared to the previous simulated results of the reference paper. Moreover, variations of characteristic impedance by insulator thickness are calculated for the insulator thickness of 0.0,0.5 and 1.0$\mu\textrm{m}$.

  • PDF

CATV 전송로를 공용하는 배전자동화시스템 (Joint use application of the CATV transmission line in DAS)

  • 박종수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.994-999
    • /
    • 1993
  • To service with high quality electricity to customer, the utilities consider the DAS (Distribution Automation System) as a good means of it. The backbone of the DAS are communication and computer technique. Most of all, from the economical and functional point of view, the selection of transmission media for system communication is the key factor to achieve a successful DAS. In this paper author propose the method of the DAS communication which share its channel with CATV transmission line and analyze the effect.

  • PDF

Characterization of wind-induced vibrations in transmission lines by single-channel field data analysis

  • Yamaguchi, Hiroki;Gurung, Chandra B.;Yukino, Teruhiro
    • Wind and Structures
    • /
    • 제8권2호
    • /
    • pp.121-134
    • /
    • 2005
  • Wind-induced vibrations measured in the Tsuruga Test Line are characterized in this paper by single-channel data analysis based on piecewise application of Prony's method. Some of events were identified as galloping, while most of events were buffeting responses, which were confirmed partly by the buffeting analysis. Effects of end condition etc. on the response characteristics are also discussed.