• Title/Summary/Keyword: Transmission

Search Result 24,752, Processing Time 0.063 seconds

High quality topological insulator Bi2Se3 grown on h-BN using molecular beam epitaxy

  • Park, Joon Young;Lee, Gil-Ho;Jo, Janghyun;Cheng, Austin K.;Yoon, Hosang;Watanabe, Kenji;Taniguchi, Takashi;Kim, Miyoung;Kim, Philip;Yi, Gyu-Chul
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.284-284
    • /
    • 2016
  • Topological insulator (TI) is a bulk-insulating material with topologically protected Dirac surface states in the band gap. In particular, $Bi_2Se_3$ attracted great attention as a model three-dimensional TI due to its simple electronic structure of the surface states in a relatively large band gap (~0.3 eV). However, experimental efforts using $Bi_2Se_3$ have been difficult due to the abundance of structural defects, which frequently results in the bulk conduction being dominant over the surface conduction in transport due to the bulk doping effects of the defect sites. One promising approach in avoiding this problem is to reduce the structural defects by heteroepitaxially grow $Bi_2Se_3$ on a substrate with a compatible lattice structure, while also preventing surface degradation by encapsulating the pristine interface between $Bi_2Se_3$ and the substrate in a clean growth environment. A particularly promising choice of substrate for the heteroepitaxial growth is hexagonal boron nitride (h-BN), which has the same two-dimensional (2D) van der Waals (vdW) layered structure and hexagonal lattice symmetry as $Bi_2Se_3$. Moreover, since h-BN is a dielectric insulator with a large bandgap energy of 5.97 eV and chemically inert surfaces, it is well suited as a substrate for high mobility electronic transport studies of vdW material systems. Here we report the heteroepitaxial growth and characterization of high quality topological insulator $Bi_2Se_3$ thin films prepared on h-BN layers. Especially, we used molecular beam epitaxy to achieve high quality TI thin films with extremely low defect concentrations and an ideal interface between the films and substrates. To optimize the morphology and microstructural quality of the films, a two-step growth was performed on h-BN layers transferred on transmission electron microscopy (TEM) compatible substrates. The resulting $Bi_2Se_3$ thin films were highly crystalline with atomically smooth terraces over a large area, and the $Bi_2Se_3$ and h-BN exhibited a clear heteroepitaxial relationship with an atomically abrupt and clean interface, as examined by high-resolution TEM. Magnetotransport characterizations revealed that this interface supports a high quality topological surface state devoid of bulk contribution, as evidenced by Hall, Shubnikov-de Haas, and weak anti-localization measurements. We believe that the experimental scheme demonstrated in this talk can serve as a promising method for the preparation of high quality TI thin films as well as many other heterostructures based on 2D vdW layered materials.

  • PDF

Changes of Radiation Dose and Image Quality Due to Additional Filtration Material in Computed Radiography (Computed Radiography에서 Additional Filtration Material에 따른 Radiation Dose와 Image Quality의 변화)

  • Kwon, Soon-Mu;Cho, Hyung-Wook;Kang, Yeong-Han;Kim, Boo-Soon;Kim, Jung-Su
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.239-246
    • /
    • 2014
  • Filter absorbs low-energy X-ray to increase the average energy and reduces patient exposure dose. This study investigates if the materials of Mo and W could be used for the digital imaging device CR by conducting image assessment and dose measurement of SNR, FOM and histogram. In addition, measurement of beam quality was conducted depending on the material of the filter, and at the same time, a proper combination of filters was examined depending on the change in tube voltage (kVp). In regard to entrance skin dose, Mo filter showed the dose reduction by 42~56%, compared to Cu filter. Moreover, Mo filter showed higher transmission dose by around 1.5 times than that of Cu filter. In image assessment, it was found that W was unsuitable to be used as a filter, whereas Mo could be used as a filter to reduce dose without decline in image quality at the tube voltage of 80 kVp or higher. As tube voltage increased, 2.0 mm Al+0.1 mm Mo almost had a similar histogram width to that of 2.0 mm Al+0.2 mm Cu. Therefore, Mo filter can be used at relatively high tube voltage of 80 kVp, 100 kVp and 120 kVp. The SNR of 2.0 mm Al+0.1 mm Mo did not show any significant difference from those of 2.0 mm Al+0.2 mm Cu and 2.0 mm Al+0.1 mm Cu. As a result, if Mo filter is used to replace Cu filter in general radiography, where 80 kVp or higher is used for digital radiation image, patient exposure dose can be reduced significantly without decline in image quality, compared to Cu filter. Therefore, it is believed that Mo filter can be applied to chest X-ray and high tube voltage X-ray in actual clinical practice.

Ultrastructural and Histochemical Studies on the Epithelial Cells and Mucus-producing Cells of Korean Slug(Limax flavus L.) (한국산 노랑민달팽이(Limax flavus L.)의 표피상피세포와 점액형성세포에 관한 미세구조 및 조직화학적인 연구)

  • Chang, Nam-Sub
    • Applied Microscopy
    • /
    • v.18 no.2
    • /
    • pp.1-20
    • /
    • 1988
  • The species of the slug used in the experiment is Limax flavus L. For identifying the chemical characteristics of the epidermis, granules and mucus-producing cell of this animal is examined with methylene blue-basic fuchsin double stain and PAS-alcian blue reagent. For the ultrastructural research of the epidermal free surface, the epitheial cell and the parenchymal cell are used with scanning electron microscope and transmission elec-tron microscope respectively. I . Epidermal tissue The epidermal tissue of the slug is observed being divided into the dorsal and the ventral side(toot pad) respectively. 1) Dorsal epidermal tissue The dorsal epidermis of the slug is constituted with the simple columnar epithelium and the microvilli are compacted on the epidermal free surface. Two different types of the secretory granules of the neutral and the acid mucus are observed between the epithelial cells, and the neutral mucous granules are highest electron-dense but the acid mucous granules are observed to be electron-lucent. 2) Foot epidermal tissue The Foot epidermis is formed with the taller simple columnar epithelium than the dorsal epidermis and these cells have both a large number of the microvilli and a few number of the large villi. The secretory granules of three different types, which are acid, neutral and mixed mucous granule of two different types are observed between the epithelial cells. The neutral mucous granules are highest electron dense but the acid mucous granules are observed to be electron-lucent. II . Mucous granule-producing cell and mucus-producing cells Seven different types of the granules-producing cell and the mucus-producing cells are observed between the parenchyma. 1) A-type of acid mucous granule-producing cell The electron-lucent granules are largely occupied in the cytoplasm of these cells and then the granules are surrounded by irregular membrane. These electron-lucent granules exhibit alcianophilia with PAS-alcian blue reaction, so these granules are certified to be acid mucopolysaccharide. 2) B-type of acid mucus-producing cell The nucleus and the cytoplasm of these cells are pushed by the acid mucus of the electron-lucent toward the cell membrane. This mucus has been confirmed to be the acid mucopolysaccharide with PAS-alcian blue reagent. 3) A-type of neutral mucous granule-producing cell These cells contain the electron-dense round granules with approximately $1{\mu}m$ in diameter, which exhibit strongly PAS-positive reaction. These granules are confirmed to be the neutral mucoplysaccharide. 4) B-type of neutral mucous granule-producing cell These cells contain two different types of electron dense granules and electron-lucent granules; The former exhibits to be strongly PAS-positive and the latter to have alcianophilia reaction respectively. 5) C-type of neutral mucus-producing cell These cells are similar to the shape and the size of the B-type of mucus-producing cell but these two different types of cells are stained with reversing properties to each other. The mucus of the C-type cell that electron-lucent is largely occupied in the cytoplasm that exhibits strongly PAS-positive reaction. 6) D-type of neutral mucous granule-producing cell These cells contain round granules about $1{\mu}m$ in size which are observed to be medium electron-dense granules and those granules are stained brightly red with PAS-weak positive reaction. The granules are certified to be neutral mucopolysaccharide. 7) E-type of neutral mucous granule-producing cell These cells are similar to the shape and the size of the D-type of neutral mucous granule-producing cell. These cells contain a large number of granules with about $1{\mu}m$ in diameter showing electron-lucent and then granules are seen to be PAS-weak positive reaction. III. Parenchyma The clear cell and dark cell are found in the parenchyma of the Limax flavus L. 1) Clear cell These cells are round formed and the nucleus of the cells are larger than cytoplasm. These cells which have the electron-lucent cytosol possess poorly developed organelles. 2) Dark cell These cells are found to be dark cells due to high electron-density, which exhibit strongly methylene-blue reaction from double stain of methylene blue-basic fuchsin.

  • PDF

Some Observations on the Intercellular Junctions between the Hepatocytes in Fasting States as Revealed by Freeze Fracture Replica (기아가 간세포막결합장치에 미치는 영향에 관한 Freeze Fracture Replica법에 의한 관찰)

  • Ahn, Tae-Soon;Shin, Young-Chul
    • Applied Microscopy
    • /
    • v.25 no.2
    • /
    • pp.53-64
    • /
    • 1995
  • This study was designed to investigate the morphological alterations of zonula occludens, macula adherences and gap junctions between the hepatocytes in the fasting conditions. Animals (Sprague Dawley, $250{\sim}280g$) were divided into two groups: normal and fasting. The latter were fasted for eight days prior to sampling. Liver tissues were sectioned and replicated after freeze fracturing for the transmission electron microscopy. In the normal rat liver, the interhepatocellular space at the area of some zonula occludens appeared to be widened in thin sections. On the freeze fracture replicas., the zonula occludens appeared as an anastomosing network of $2{\sim}4$ strands or grooves on P or E faces. Free ends and fragments of the strands were observed. In the rat fasted for eight days, the hepatocytes were diminished in size and the organelles were decreased in number and size. The intercellular space was wide at many areas of zonula occludens in thin section. On the freeze fracture replicas, the zonula occludens showed diminution or disappearence of anastomosing network of strands or grooves. Free ends and small fragments of the strands or grooves were frequently encountered. The macula adherens was markedly increased in number in thin sections, although they could not be found on the freeze fracture replicas. The gap junctions were increased in number in thin sections. Small aggregations of the intramembranous particles appeared with larger ones on the freeze fracture replica. The evidences may suggest the followings: (1) The disassembly of zonula occludens in the fasting states is led from the diminished mechanical stress on the luminal surface of bile canaliculus with the impaired secretion of bile components from the hepatocytes. (2) The increase of macula adherens is necessary to maintain the liver parenchyma integrity in the fasting state which leads the hepatocyte to be diminished and finally the intercellular space to be separated. (3) The rise in both number and size of gap junctions is owing to the need of increasing intercellular communication between the hepatocytes during the fasting. (4) The alteration of zonula occludens is easily led by the physiological condition of hepatocytes even in the normal ones.

  • PDF

Characteristics of 15 MV Photon Beam from a Varian Clinac 1800 Dual Energy Linear Accelerator (CLINAC 1800 선형가속기의 15 MV X-선의 특성)

  • Kim, Kye-Jun;Lee, Jong-Young;Park, Kyung-Ran
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.131-141
    • /
    • 1991
  • A comprehensive set of dosimetric measurements has been made on the Varian Clinac 1800 15 MV photon beam. Beam quality, percentage depth dose, dose in the build up region, output, symmetry and flatness, transmission through iead (Cerrobend), tray attenuation, isodose curves for the open and wedged fields were measured using 3 dimensional water phantom dosimetry system (including film densitometer system) and polystyrene phantoms. These dosimetric measurements sufficiently characterized the beam to permit clinical use. The depth dose characteristics of photon beam is $d_{max}$ of 3.0 cm and percentage depth dose of $76.8\%$ at 10 cm,100 cm source-surface distance, field size of $10\times10\;cm^2$ for 15 MV X-ray beam. The Output factors ranged 0.927 for $4\times4\;cm^2$ field to 1,087 for $35\times35\;cm^2$ field. The build-up level of maximum dose was at 3.0 cm and surface dose was approximately $15.5\%$ for a field size $10\times10\;cm^2$ The stability of output is $within\pm1\%$ and flatness and symmetry are $within\pm3\%$. The half value thickness (HVL) of lead is 13 mm, which corresponds to an attenuation coefficient of $0.053\;mm^{-1}$. These figures compare facorably with the manufacturesr`s specifications.

  • PDF

Effect of FS11052, an Inhibitor of Exocytosis, on Neurite Extension in Rat Hippocampal Neurons and PC12 Cells (신경전달물질 방출 저해제 FS11052가 신경세포와 PC12 세포의 돌기신장에 미치는 영향)

  • Lee Yun-Sik;Kim Dong-Seob
    • Journal of Life Science
    • /
    • v.16 no.2 s.75
    • /
    • pp.315-322
    • /
    • 2006
  • FS11052, a novel microbial metabolite from Streptomyces spp. was identified as a small molecular substance and shown inhibition activities for the release of neurotransmitter from rat hippocampal neuron and PC12 cells. FS11052 is an inhibitor of tritiated norepinephrine ($[^3H]-NE$) release in high $K^+$ buffer solution containing ionomycin, indicating that FS11052 inhibits neurotransmitter release after the influx of $Ca^{2+}$ ions. When examined the effect of FS11052 on glucuronidase release from guinea pig neutrophils, FS11052 inhibited glucuronidase release: when treated with $5{\mu}g/ml$ of FS11052, which was not induced cellular cytotoxicity. The fact that the glucuronidase release in neutrophil and norepinephrine release in neuron was inhibited suggests the similarity in the locations and the mechanisms of FS11052 action targets. When treated with $5{\mu}g/ml$ of FS11052, $[^3H]-NE$ release and neurite extension for both rat hippocampal neurons and PC12 cells were prevented. These observations of FS11052 functioning as an inhibitor of neurotransmitter release suggest that FS11052 has an important role in synaptic transmission in neuron.

Development of the Whole Body 3-Dimensional Topographic Radiotherapy System (3차원 전신 정위 방사선 치료 장치의 개발)

  • Jung, Won-Kyun;Lee, Byung-Yong;Choi, Eun-Kyung;Kim, Jong-Hoon;An, Seung-Do;Lee, Seok;Min, Chul-Ki;Park, Cham-Bok;Jang, Hye-Sook
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.63-71
    • /
    • 1999
  • For the purpose of utilization in 3-D conformal radiotherapy and whole body radiosurgery, the Whole Body 3-Dimensional Topographic Radiation Therapy System has been developed. Whole body frame was constructed in order to be installed on the couch. Radiopaque catheters were engraved on it for the dedicated coordinate system and a MeV-Green immobilizer was used for the patient setup by the help of side panels and plastic rods. By designing and constructing the whole body frame in this way, geometrical limitation to the gantry rotation in 3-D conformal radiotherapy could be minimized and problem which radiation transmission may be altered in particular incident angles was solved. By analyzing CT images containing information of patient setup with respect to the whole body frame, localization and coordination of the target is performed so that patient setup error may be eliminated between simulation and treatment. For the verification of setup, the change of patient positioning is detected and adjusted in order to minimize the setup error by means of comparison of the body outlines using 3 CCTV cameras. To enhance efficiency of treatment procedure, this work can be done in real time by watching the change of patient setup through the monitor. The method of image subtraction in IDL (Interactive Data Language) was used to visualize the change of patient setup. Rotating X-ray system was constructed for detecting target movement due to internal organ motion. Landmark screws were implanted either on the bones around target or inside target, and variation of target location with respect to markers may be visualized in order to minimize internal setup error through the anterior and the lateral image information taken from rotating X-ray system. For CT simulation, simulation software was developed using IDL on GUI(Graphic User Interface) basis for PC and includes functions of graphic handling, editing and data acquisition of images of internal organs as well as target for the preparation of treatment planning.

  • PDF

Analysis of Occlusal Contacts Using Add-picture Method (Add-picture 방법을 이용한 교합접촉점 분석)

  • Park, Ko-Woon;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.45-58
    • /
    • 2013
  • The purpose of this study was to analyze the area of occlusal contact points using visual method. One subject was selected who had Angle Class I, normal dentition, without dental caries, periodontal disease and temporomandibular disorders. Forty times PVS impressions were taken and 10 pairs casts were fabricated using dental super hard stone. After mounting the casts with customized loading apparatus, 78.9kg/f force was loaded as a maximum biting force. In T-Scan method, occlusal contact points measurement was repeated twice. Then, using Photoshop program (Adobe photoshop CS3, Adobe. San Jose, USA), the pixels which indicated occlusal contact points by color was recognized, and the distribution of recognized pixels were calculated to area. In Add picture method, polyether bite material applied to the occlusal surface of the casts. Then, the image of the translucent areas was recorded and classified $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area by the amount of transmitted light. To acquire occlusal surface, the numbers of pixels from the photograph of the contact area indicated cast converted to $mm^2$. The mean occlusal contact area by two methods was statistically analyzed (paired t-test). Part of the red and pink area in T-Scan image were almost equivalent to the $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area in Add picture image. The distribution of occlusal contact points were similar, but the average area of occlusal contact points was wider in T-scan image (P<.05). Pink and red area in T-scan image was wider than $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$ area in Add picture image (P<.05), but similar to $0{\sim}60{\mu}m$area in Add picture image (P>.05). Occlusal contact points in T-scan image did not indicate real occlusal contact points. Occlusal contact areas in T-scan method were enlarged results comparing with those in Add picture method.

A study on the origination and Transmission of Yu in Northeast Asia. -from the 4th Century to the 8th Century- (동북(東北)아시아 유의 기원(起源)과 그 교류(交流)에 관(關)한 연구(硏究) -$4{\sim}8$세기(世紀)를 중심(中心)으로-)

  • Cho, Sun-Hee;Park, Kyung-Ja
    • Journal of the Korean Society of Costume
    • /
    • v.17
    • /
    • pp.29-43
    • /
    • 1991
  • Yu was a type of dress worn on the upper part of the body which was commonly used in Northeast Asia. It was originally used by the Northern race for the need of courtesy as well as protecting cold. It was believed that Yu in Northeast Asia, which was called Kaftan, was came from Scythai lived in North Eurasian land around the Black sea. Scythians were the first-formed horse-riding race in the world and their civilization influenced those of far Asiatic sector along the steppe route. As their power expanded, their costume culture transmitted to the East(China, Korea, Japan). The upper garment, Yu, was characterized by the left-sided collars, narrow sleeves belted at the waist to the length of the hip line and the tight trouser on the lower part, which we commonly called HoBok(胡服) style. 1. Yu in Northeast Asia was originated from the Eurasians, Scythian Culture. Being exchanged, active style costumes were widely used among Chinese, Koreans and Japanese throughout centuries' including $4{\sim}8$ century. 2. Chinese Yu had a style of wide-sleeves and right-sided collars. The traditional costumes of Han race are consisted of wide-sleeved Yu on the upper and long-skirt on the lower part of the body. Before the adoptation of HoBok during reign of King Jo Mooryung in 307. B.C., HoBok style had already found in the remains since the Sang period. There were various names among Yu during the Han period. Seup, Sean Eui, Kye, Kyu were one of the styles and several names were meant for collar and sleeves. During $4{\sim}8$ centuries, clothes of right-sided collar were found, superior to that of left-sided and narrow sleeves were widely used both the royal and the humble. Various styles of decoration were seen in Yu around neck, back and sleeves comparing other nations. 3. Yu, in Korea, was typical style of Northern-bound HoBok. Both men and women had similarity in Yu style, narrow sleeves, left-sided collar, belted at the waist and to the length of hip line. Influenced by Han race, in the $4th{\sim}8th$ centuries, dual system of collar was found. But we cannot see major change in Yu and finally was connected to the present. 4. The original design of the Japanese costumes was not similar to that of Northern nomadic hunting race, which was suitable for horse-riding activities. Owing to the climates along the island, we could see various conditions ranging from the cold and to the warm. Influenced by the climates, pulling over the neck(Pancho style) were major design in Japan. As Korea was advanced earlier than Japan, Korean landed Japanese territory showing clothes. So primitive costumes had changes in style. During the $4th{\sim}8th$ period. The Korean mode was found in Haniwa (which was built to make sacrifices to the dead King) and costumes in Jeong Chang Won. Among the costumes in Jeong Chang Won, we put 3 or more costumes to the category of Yu characterizing elements of Korea and Tang period. From the $4th{\sim}8th$ century, China, Korea, Japan fell into the same cultural category, Scythai. Styles in Yu among three nations, we saw little differences, basically along times. Originated from the West Asia, Yu was transmitted to the far East changing Chinese costumes, Koreans melted it into the traditional elements and then influenced Japan.

  • PDF

The Evaluation for Attenuation Map using Low Dose in PET/CT System (PET/CT 시스템에서 감쇠지도를 만들기 위한 저선량 CT 평가)

  • Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Lee, Chang-Lae;Lim, Han-Sang;Park, Hoon-Hee;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.134-138
    • /
    • 2007
  • The current PET/CT system with high quality CT images not only increases diagnostic value by providing anatomic localization, but also shortens the acquisition time for attenuation correction than primary PET system. All commercially available PET/CT system uses the CT scan for attenuation correction instead of the transmission scan using radioactive source such as $^{137}Cs,\;^{68}Ge$. However the CT scan may substantially increase the patient dose. The purpose of this study was to evaluate quality of PET images reconstructed by CT attenuation map using various tube currents. in this study, images were acquired for 3D Hoffman brain phantom and cylindrical phantom using GE DSTe PET/CT system. The emission data were acquired for 10 min using phantoms after injecting 44.03 MBq of $^{18}F-FDG$. The CT images for attenuation map were acquired by changing tube current from 10 mA to 95 mA with fixed exposure time of 8 sec and fixed tube voltage of 140 kVp. The PET images were reconstructed using these CT attenuation maps. Image quality of CT images was evaluated by measuring SD (standard deviation) of cylindrical phantom which was filled with water and $^{18}F-FDG$ solution. The PET images were evaluated by measuring the activity ratio between gray matter and white matter in Hoffman phantom images. SDs of CT images decrease by increasing tube current. When PET images were reconstructed using CT attenuation maps with various tube currents, the activity ratios between gray matter and white matter of PET images were almost same. These results indicated that the quality of the PET images using low dose CT data were comparable to the PET images using general dose CT data. Therefore, the use of low dose CT is recommended than the use of general dose CT, when the diagnostic high quality CT is not required. Further studies may need to be performed for other system, since this study is limited to the GE DSTe system used in this study.

  • PDF