• Title/Summary/Keyword: Transmembrane

Search Result 591, Processing Time 0.031 seconds

Filtration Characteristics according to Hollow Fiber Dispersion in Submerged Membrane Module (침지형 막모듈에서 중공사 분산에 따른 여과특성)

  • 이재인;신춘환
    • Journal of Environmental Science International
    • /
    • v.9 no.2
    • /
    • pp.173-176
    • /
    • 2000
  • This study was carried out to investigate the filtration characteristics of membrane modules according to hollow fiber dispersion for direct solid-liquid separation of activated sludge. 2 bundle, 4 bundle, and 10 bundle, and 10 bundle module used in this experiment according to hollow fiber dispersion was manufactured at laboratory and permeate flux and transmembrane pressure(TMP) of each module were observed under a suction pressure of 0.5kgf/c$m^2$. As the hollow fibers were dispersed, permeate flux was increased and TMP was decreased. Permeate flux and TMP of each module was 15.0 $\ell$/$m^2$.h and 31.8 cmHg for 2 bundle, 16.0 $\ell$/$m^2$ .h and 17.4 cmHg for 4 bundle, and 20.4 $\ell$/m2 .h and 31.8 cmHg for 10 bundle. In conclusion, the membrane fouling is expected to be decrease by maintaining lower TMP with hollow fiber dispersion.

  • PDF

Effect of Glycyrrhizin on the Aoptosis of Melanoma Cells in Mel/ret Transgenic Mice (Glycyrrhizin이 Mel/ret transgenic mice에서의 melanoma 세포의 apoptosis에 미치는 영향)

  • 오찬호;염정열
    • KSBB Journal
    • /
    • v.13 no.6
    • /
    • pp.718-723
    • /
    • 1998
  • The effect of glycyrrhizin on melanoma cells was investigated. DNA fragmentation in cultured melanoma cells was promoted by the addition of glycyrrhizin in a dose dependent manner. Administration(i.m.) of glycyrrhizin to Mel/ret transgenic mice resulted in apoptosis induction, reduction of mitochondrial transmembrane potential in melanoma cells. Decreased B220+ B cells were recovered by the treatment of glycyrrhizin in splenocytes and mesenteric lymph node cells, while Thy-1+ T cells were not influenced. Results suggested that glycyrrhizin acted as an inducer of apoptosis of melanoma cells and an immuno-potentiator via recovered B lymphocyte population in Mel/ret transgenic mice.

  • PDF

The Effect of the Variation of Hollow Fiber Diameter and Curvature and Turn Number on Performance for Microfiltration Helical Modules (Microfiltration Helical Module들에서 Hollow Fiber의 Diameter과 Curvature 및 Turn수의 변화에 따른 성능변화에 관한 연구)

  • 이광현
    • Membrane Journal
    • /
    • v.7 no.2
    • /
    • pp.84-94
    • /
    • 1997
  • The performances of both module sets made by different methods for helical module were compared. All experiments were conducted simultaneously at the same transmembrane pressure and energy cosumption per membrane area. The effects of Dean vortices for reducing concentration polarization and fouling were low for the first module set. The increase of 115% for permeate flux improvement(permeate flux difference ${\times}100$/pemeate flux of linear module) was measured. The second module set was more effective in reducing concentration polarization and fouling.

  • PDF

COD removal from industrial wastewater plants using reverse osmosis membrane

  • Madaeni, S.S.;Samieirad, S.
    • Membrane and Water Treatment
    • /
    • v.1 no.4
    • /
    • pp.273-282
    • /
    • 2010
  • Treatment and reuse of industrial wastewater is becoming a major goal due to water scarcity. This may be carried out using membrane separation technology in general and reverse osmosis (RO) in particular. In the current study, polyamide (FT-30) membrane was employed for treatment of wastewater obtained from Faraman industrial zone based in Kermanshah (Iran). The effects of operating conditions such as transmembrane pressure, cross flow velocity, temperature and time on water flux and rejection of impurities including COD by the membrane were elucidated. The aim was an improvement in membrane performance. The results indicate that most of the chemical substances are removed from the wastewater. In particular COD removal was increased from 64 to around 100% as temperature increased from 15 to $45^{\circ}C$. The complete COD removal was obtained at transmembrane pressure of 20 bars and cross flow velocity of 1.5 m/s. The treated wastewater may be reused for various applications including makeup water for cooling towers.

Membrane distillation of power plant cooling tower blowdown water

  • Ince, Elif;Uslu, Yasin Abdullah
    • Membrane and Water Treatment
    • /
    • v.10 no.5
    • /
    • pp.321-330
    • /
    • 2019
  • The objective of this study was to examine the recovery of the power plant cooling tower blowdown water (CTBD) by membrane distillation. The experiments were carried out using a flat plate poly vinylidene fluoride (PVDF) membrane with a pore diameter of $0.22{\mu}m$ by a direct contact membrane distillation unit (DCMD). The effects of operating parameters such as transmembrane temperature difference (${\Delta}T$), circulation rate and operating time on permeate flux and membrane fouling have been investigated. The results indicated that permeate flux increased with increasing ${\Delta}T$ and circulation rate. Whereas maximum permeate flux was determined as $47.4L/m^2{\cdot}h$ at ${\Delta}T$ of $50^{\circ}C$ for all short term experiments, minimum permeate flux was determined as $7.7L/m^2{\cdot}h$ at ${\Delta}T$ of $20^{\circ}C$. While $40^{\circ}C$ was determined as the optimum ${\Delta}T$ in long term experiments. Inorganic and non-volatile substances caused fouling in the membranes.

Antisense Oligonucleotide Therapeutics for Cystic Fibrosis: Recent Developments and Perspectives

  • Young Jin Kim;Adrian R. Krainer
    • Molecules and Cells
    • /
    • v.46 no.1
    • /
    • pp.10-20
    • /
    • 2023
  • Antisense oligonucleotide (ASO) technology has become an attractive therapeutic modality for various diseases, including Mendelian disorders. ASOs can modulate the expression of a target gene by promoting mRNA degradation or changing pre-mRNA splicing, nonsense-mediated mRNA decay, or translation. Advances in medicinal chemistry and a deeper understanding of post-transcriptional mechanisms have led to the approval of several ASO drugs for diseases that had long lacked therapeutic options. For instance, an ASO drug called nusinersen became the first approved drug for spinal muscular atrophy, improving survival and the overall disease course. Mutations in the cystic fibrosis transmembrane conductance regulator (CFTR) gene cause cystic fibrosis (CF). Although Trikafta and other CFTR-modulation therapies benefit most CF patients, there is a significant unmet therapeutic need for a subset of CF patients. In this review, we introduce ASO therapies and their mechanisms of action, describe the opportunities and challenges for ASO therapeutics for CF, and discuss the current state and prospects of ASO therapies for CF.

Performance Evaluation of MF Membrane Filtration Pilot System Associated with Pre Coagulation-Sedimentation with Iron-Based Coagulant and Chlorination Treatment (철염계 응집제를 사용한 전응집침전, 전염소처리와 PVDF 재질의 정밀여과 막을 조합한 막 여과 정수처리시스템 평가에 관한 연구)

  • Lee, Sanghyup;Jang, Nakyong;Yoshimasa, Watanabe;Choi, Yongsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.588-597
    • /
    • 2004
  • In this research, we investigated the variation of transmembrane pressure and permeate water quality with pre coagulation and sedimentation with iron based coagulant and chlorination of feed water for PVDF (polyvinylidene fluoride) based MF membrane filtration. NaCIO was fed to the membrane module with dosage of 0.5mg/L and maintained during filtration. To observe the effect of raw water, three types of raw and processed waters, including river surface water, coagulated water and coagulated-settled water, were applied. In case of river surface water, the transmembrane pressure increased drastically in 500 hours of operation. On the contrary, no significant increase in transmembrane pressure was observed for 1,200 hours of operation for coagulated water and coagulated-settled waters. The turbidity of permeate was lower than a detection limit of equipment for all raw waters. The removal efficiency of humic substances of coagulated water and coagulated-settled water was approximate ten times of that of surface river water. And, the removal efficiency of TOC and DOC was approximate two times of that of surface river water. From the results of plant operation, stable operation was maintained at $0.9m^3/m^2{\cdot}day$ filtration flux through the combination of pre-coagulation and pre-chlorination. However, the water quality of permeate was the best when pre-coagulation-sedimentation process was combined with pre-chlorination.

Studies on the Membrane Topology of the (Na, K) ATPase

  • Lee, Kyunglim-Yoon
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.181-181
    • /
    • 1996
  • The (Na, K) ATPase is a membrane ion transporting ATPase composed of an ${\alpha}$ catalytic subunit and a ${\beta}$ glycoprotein subunit. The topology of the rat ${\alpha}$1 and ${\beta}$1 subunits has been studied by insertion of epitope(s) : at the NH2-terminus and COOH-terminus and between Glu117 and Glul18, Lys828 and Arg829, Gln900 and Trp901, and Va1939 and Phe940 of the ${\alpha}$ subunit; and at the NH2-terminus and COOH-terminus and between Glu228 and Tyr229 of the ${\beta}$ subunit. The epitope-tagged ${\alpha}$l, constructs were expressed in HeLa cells to select for stable cell lines expressing a functional (Na, K)ATPase. All constructs, except for the one tagged between Gln900 and Trp901, resulted in ouabain-resistant colonies indicating that modified proteins retained functional integrity. The epitope-tagged ${\beta}$ constructs were transiently expressed in Cos-7 cells. The orientation of the epitopes with respect to the cell membrane was revealed by indirect immunofluorescence performed on permeabilized and non-permeabilized cells expressing the (Na, K)ATPase chains. The results indicate that the ${\alpha}$ subunit has 4 transmembrane segments in the COOH terminal membrane bound domain between residues 760 and 938, and that both the NH2-terminus and the COOH-terminus are in the cytosol; it was not determined whether there are more transmembrane segments between residue 938 and the COOH-terminus. The ${\beta}$ subunit has only one transmembrane spanning region with the NH2-terminus in the cytosol and the COOH-terminus on the extracytoplasmic surface of the plasma membrane.

  • PDF