• Title/Summary/Keyword: Transient state flow

Search Result 246, Processing Time 0.031 seconds

Exergy Analysis of On/Off Controlled Heat Pump

  • Jang, Ki-Tae;Nam, Kwan-Woo;Jeong, Sang-Kwon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.22-32
    • /
    • 1999
  • A multi-type heat pump controls the mass flow rate of the working fluid to cope with variable heat loads when it is under dynamic load condition. This paper describes the exergy analysis associated with the unsteady response of a heat pump. First, a basic heat pump cycle is examined at a steady state to show the general trends of exergy variations in each process of the cycle. Entropy generation issue for the heat exchangers is discussed to optimize the heat pump cycle. Secondly, the performance of the inverter-driven heat pump is compared to that of the conventional one when the heat load is variable. Thirdly, the exergy destruction rate of the heat pump with On/Off operation is calculated by simulating the thermodynamic states of the working fluid in the condenser and the evaporator. The inefficiency of On/Off operation during the transient period is quantitatively described by the exergy analysis.

  • PDF

Development and Application of Measuring Method of Instantaneous Intensity (순시 인텐시티 측정 기법의 개발 및 응용)

  • 이장우;김영종;안병하;이운섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.560-563
    • /
    • 1997
  • Sound intensity method is well known as a visualization technique of sound field and sound propagation in noise control. Sound intensity is a vector quantity that describes the magnitude and the direction of net flow of acoustic energy at a given position. The current measuring method is expensive and difficult to identify the noise source exactly. In this paper, we have studied the noise source identification and the characteristics of noise source of rotary compressor for air conditioner using complex sound intensity method. The new method for instantaneous sound intensity is also proposed and it is useful for transient state and steady state. The criteria of these states select auto correlation coefficient. The advantage, simplicity and economic attribution of this method are verified by analyzing the characteristics of noise source with instantaneous sound intensity compared to mean sound intensity.

  • PDF

A Study on the Energy Distribution of Interface Traps in MOS Devices Under Non-steady-state (비정상상태에 있는 MOS내의 경사면트랩에너지 분포에 관한 연구)

  • Cho, Chul;Kim, Jae-Hoon
    • 전기의세계
    • /
    • v.26 no.6
    • /
    • pp.86-92
    • /
    • 1977
  • The phenomenon of non-steady-state current flow through the interface traps during the dielectric relaxation of MOS device is presented. Experimental method is also described for determining the energy distribution of interface traps, which is based on isothermal dielectric relaxation current technique. Actually, the energy distribution of interface traps was obtained by measuring the transient current through the traps at Si-SiO$_{2}$ interface only in lower-half of the bandgap. It is shown that the trap energy distributio has peak value 1.72*10$^{13}$ cm$^{-2}$ eV$^{-1}$ near 0.73eV approximately.

  • PDF

Harmonics Analysis of Distribution System using PTW (PTW를 이용한 수변전 계통의 고조파 분석기법)

  • 설용태;이의용;김응래;최종문
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.80-86
    • /
    • 2001
  • This paper describes the harmonic analysis method of industrial power systems using PTW(Power Tools for Window). Voltage/current distortion levels and filter at steady state are calculated by harmonic load flow. Special features of its input processes PTW is utilized in order to facilitate creation of new simulation cares. Harmonics at transient state, the filter and the load variation, are analysed to diagnosis the power quality in actual industrial plant model.

  • PDF

Intraoperative Transcranial Doppler Monitoring (수술중 경두개 초음파 집중감시)

  • Seo, Dae Won
    • Annals of Clinical Neurophysiology
    • /
    • v.1 no.1
    • /
    • pp.70-75
    • /
    • 1999
  • Trancranial Doppler(TCD) monitoring is a new application of ultrasonography which allows the nonivasive detection of blood flow velocity in the horizontal (M1) segment of the middle cerebral artery (MCA) and detects microembolic phenomena in the cerebral circulation. Recent studies emphasized the potential of using this technique in vascular surgery (carotid endarterectomy, cardiopulmonary bypass), interventional and intensive care setting. Although the disparity between CBF and blood flow velocity and number of microemboli could be used to prevent cerebral ischemic and embolism based on clinical studies. A reduction of more than 60% of MCA can reflex hemodynamic ischemic state and acoustic feedback of high intensity transient signals(HITS) from the TCD monitoring unit has a direct influence on surgical technique. TCD monitoring can immediately provide information about thromboembolism and hemodynamic changes, which may be a useful tool in the study and prevention of stroke.

  • PDF

Dual-Porosity Models with Linear Flow Pattern (매트릭스 블록선형유동에 관한 이중공극 모델)

  • 함세영;성익환
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • This study deals with linear flow pattern in steady-state or transient dual-porosity media with a vertical geologic structure such as fault, fracture zone, etc. A pumping well is located in the vertical structure of infinitesimal or finite width with high hydraulic conductivity and negligible specific storage. Selected type curves on a pumping well and observation wells in the fractured system and the matrix block are provided. The type curves on the pumping well considers both wellhole and well-loss effects.

  • PDF

Development of a Subchannel Analysis Code MATRA Applicable to PWRs and ALWRs

  • Yoo, Yeon-Jong;Hwang, Dae-Hyun;Sohn, Dong-Seong
    • Nuclear Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.314-327
    • /
    • 1999
  • A subchannel analysis code MATRA applicable to PWRs and ALWRs has been developed to be run on an IBM PC or HP WS based on the existing CDC CYBER mainframe version of COBRA-Rf-1. This MATRA code is a thermal-hydraulic analysis code based on the subchannel approach for calculating the enthalpy and How distribution in fuel assemblies and reactor cores for both steady-state and transient conditions. HATRA has been provided with an improved structure, various functions, and models to give more convenient user environment and to enhance the code accuracy. Among them, the pressure drop model has been improved to be applied to non-square-lattice rod arrays, and the models for the lateral transport between adjacent subchannels have been improved to enhance the accuracy in predicting two-phase flow phenomena. The predictions of MATRA were compared with the experimental data on the flow and enthalpy distribution in some sample rod-bundle cases to evaluate the performance of MATRA. All the results revealed that the predictions of MATRA were better than those of COBRA-IV-I.

  • PDF

A NUMERICAL STUDY OF THE VENTILATION AND FIRE SIMULATION IN A ROAD TUNNEL (도로터널 환기/제연 시스템 시뮬레이션)

  • Park, Jong-Tack;Won, Chan-Shik;Hur, Nahm-Keon;Cha, Cheol-Hyun
    • Journal of computational fluids engineering
    • /
    • v.11 no.4 s.35
    • /
    • pp.20-25
    • /
    • 2006
  • In the present study, flow characteristics inside a road tunnel are simulated for the ventilation flows due to jet fan system and flows induces by the traffic. Traffic ventilation is numerically simulated by multiple reference frame. From the results of steady state simulation of tunnel ventilation, it is found that the proper ventilation is achieved by the designed jet fan system along with ventilating flow induced by the traffic. A transient simulation is also performed for the case of vehicle fire in the tunnel reversing the direction of rotation of some fans. The results suggest that the heat and smoke can be controlled by the proper changing of fan operation mode. The present results can be used to design proper ventilation system and effective smoke control system as well.

The Study on Sizing of the Pressure Relief Valve for Overpressure Protection of a Reactor Pressure Vessel in Low Temperature Condition (저온 상태의 원자로 압력용기의 과압방지를 위한 압력방출밸브 용량 결정에 관한 연구)

  • Lee, Jun;Kim, Yoo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.4 no.2
    • /
    • pp.7-12
    • /
    • 2008
  • The purpose of this study is to present a methodology to estimate the capacity of the pressure relief valve which prevents overpressure of the pressure vessel in a cold state. In this methodology, the transient behavior of the flow rate through the pressure relief valve and the pressure inside the pressure vessel are considered. The result of this study shows the followings; The more the relief valve capacity is considered in excess, the more the initial relief flow rate and the initial pressure inside the pressure vessel are high and low respectively. When the relief valve capacity is determined properly, the pressure inside the pressure vessel maintains almost the same value, so the ASME code requirement will be met.

  • PDF

Surge Control of Small Turbojet Engines with Fuzzy Inference Method (소형 터보제트 엔진의 서지 제어를 위한 퍼지추론 기법)

  • Jie, Min-Seok;Hong, Seung-Beom
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.17 no.4
    • /
    • pp.1-7
    • /
    • 2009
  • The surge control system in unmanned turbojet engine must be capable of accounting uncertainties from engine transient conditions, random fluctuations of key parameters such as air pressure and fuel flow and engine modeling errors. In this paper, taking into consideration of its effectiveness as well as system stability, a fuzzy PI controller is proposed. The role of the fuzzy PI controller is to stabilize the unmanned aircraft upon occurring unexpected engine surge. The proposed control scheme is proved by computer simulation using a linear engine model. The simulation results on the state space model of a small turbojet engine illustrate the proposed control system achieves the desired performance.

  • PDF