• 제목/요약/키워드: Transient performance

검색결과 1,498건 처리시간 0.027초

3가지 접지방식에 대한 접지특성비교 (The Comparison on Grounding Characteristics for 3 Grounding Systems)

  • 신동호;김용;백수현;이은영;김필수;조대훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권6호
    • /
    • pp.289-297
    • /
    • 2000
  • This paper presents a comparison on the resistance and characteristics of transient response of grounding systems under surge currents using frequency domain electromagnetic field analysis software package and field test. Analysis is done by computer model, based on electromagnetic field theory approach, that accurately takes into account frequency dependent characteristics of the system. The transient performance of three grounding systems is analyzed by comparison of frequency dependent impedance and the maximal transient GPR. A double exponential lighting surge current is injected at one corner of the grounding systems. The transient GPRs a rod grounding systems are higher than mesh or electrolytic grounding systems. Af field test, the results of resistance measurement and time-variant of ground resistance slightly reduce electorlytic grounding systems less than rod and mesh grounding systems.

  • PDF

LPC 켑스트럼 거리 기반의 천이구간 정보를 이용한 음성의 가변적인 시간축 변환 (Variable Time-Scale Modification of Speech Using Transient Information based on LPC Cepstral Distance)

  • 이성주;김희동;김형순
    • 음성과학
    • /
    • 제3권
    • /
    • pp.167-176
    • /
    • 1998
  • Conventional time-scale modification methods have the problem that as the modification rate gets higher the time-scale modified speech signal becomes less intelligible, because they ignore the effect of articulation rate on speech characteristics. Results of research on speech perception show that the timing information of transient portions of a speech signal plays an important role in discriminating among different speech sounds. Inspired by this fact, we propose a novel scheme for modifying the time-scale of speech. In the proposed scheme, the timing information of the transient portions of speech is preserved, while the steady portions of speech are compressed or expanded somewhat excessively for maintaining overall time-scale change. In order to identify the transient and steady portions of a speech signal, we employ a simple method using LPC cepstral distance between neighboring frames. The result of the subjective preference test indicates that the proposed method produces performance superior to that of the conventional SOLA method, especially for very fast playback case.

  • PDF

Transient Analysis of a Simple Cycle Gas Turbine Engine

  • Kim, SooYong;Soudarev, B.
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제1권2호
    • /
    • pp.22-29
    • /
    • 2000
  • A method to simulate the gas turbine transient behavior is developed. The basic principles of the method and main input data required are described. Calculation results are presented in terms of whole operating regime of the engine. The influence of initial parameters such as starting engine power, moment of inertia of the rotor, fuel schedule on performance characteristics of gas turbine during transient operation is shown. In addition, the effect of bleeding air on transient behavior is also considered. For validation of the developed computer code, a comparative analysis with experimental data obtained from a heavy duty gas turbine is made. Calculation results agree well with the experimental data for the range of operating regime studied and proved applicability of the developed technique to initial design stage of control system.

  • PDF

적외선 센서 냉각용 극저온 용기의 과도 냉각 특성에 관한 수치해석 (Numerical Analysis on the Transient Cooling Characteristics of an Infrared Detector Cryochamber)

  • 이정훈;김호영;강병하
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.68-72
    • /
    • 2002
  • This work investigates the transient cooling characteristics of an Infrared (IR) detector cryochamber, which has a critical effect on the cooling load. The current thermal modeling considers the conduction heat transfer through a cold well. the gaseous conduction due to outgassing. and the radiation heat transfer. The transient cooling Performance. i.e. the penetration depth and cooling load, is determined using a finite difference method. It is found that the penetration depth increases as the bore conductivity increases. Gaseous conduction and radiation hardly affect the penetration depth. The transient cooling load increases as the bore conductivity increases. The effects of gaseous conduction and radiation on transient heat transfer are weak at initial stages of cooling. However, their effects become significant as the cooling Process Proceeds.

상분리법에 의한 유도전동기의 토오크 과도특성해석 (Analysis of the torque transient performance of the induction motor by means of phase segregation method)

  • 정종호;이은웅;최재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.247-249
    • /
    • 2000
  • Transient phenomena cause delay in control response and must be studied and eliminated, if possible, suppressed. The difficulty in analyzing transient phenomena in ac machines comes from the large number of windings involved. But, it is possible that only one phase is used to represent three phases of the induction motor as called phase segregation method. The phase segregation method provides equivalent circuits for both the steady and transient states of induction motor. In this paper, analysis of the torque transient of the induction motor be carried out the phase segregation method and confirmed in the possibility of transientless torque control.

  • PDF

Soft-Switching Auxiliary Current Control for Improving Load Transient Response of Buck Converter

  • Kim, Doogwook;Shin, Joonho;Shin, Jong-Won
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2020년도 전력전자학술대회
    • /
    • pp.160-162
    • /
    • 2020
  • A control technique for the auxiliary buck/boost converter is proposed herein to improve the load transient response of the buck converter. The proposed technique improves the system efficiency by enabling the soft switching operation of the auxiliary converter. The design guidelines for achieving capacitor charge balance for the output capacitor during the transient are also presented herein. The experimental results revealed that the output voltage undershoot and settling time during the load step-up transient were 40 mV and 14 ㎲, respectively, and the output voltage overshoot and settling time during the load step-down transient were 35 mV and 21 ㎲, respectively. The performance and effectiveness of the proposed technique were experimentally verified using a prototype buck converter with a 15-V input, 3.3-V output, and 200-kHz switching frequency.

  • PDF

Boundary condition coupling methods and its application to BOP-integrated transient simulation of SMART

  • Jongin Yang;Hong Hyun Son;Yong Jae Lee;Doyoung Shin;Taejin Kim;Seong Soo Choi
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.1974-1987
    • /
    • 2023
  • The load-following operation of small modular reactors (SMRs) requires accurate prediction of transient behaviors that can occur in the balance of plants (BOP) and the nuclear steam supply system (NSSS). However, 1-D thermal-hydraulics analysis codes developed for safety and performance analysis have conventionally excluded the BOP from the simulation by assuming ideal boundary conditions for the main steam and feed water (MS/FW) systems, i.e., an open loop. In this study, we introduced a lumped model of BOP fluid system and coupled it with NSSS without any ideal boundary conditions, i.e., in a closed loop. Various methods for coupling boundary conditions at MS/FW were tested to validate their combination in terms of minimizing numerical instability, which mainly arises from the coupled boundaries. The method exhibiting the best performance was selected and applied to a transient simulation of an integrated NSSS and BOP system of a SMART. For a transient event with core power change of 100-20-100%, the simulation exhibited numerical stability throughout the system without any significant perturbation of thermal-hydraulic parameters. Thus, the introduced boundary-condition coupling method and BOP fluid system model can expectedly be employed for the transient simulation and performance analysis of SMRs requiring daily load-following operations.

지/단락실증시험에서 MW급 계통연계형 ESS 절연/보호시스템 성능 분석에 관한 연구 (Analysis on Insulation and Protection Characteristics of Grid Connected ESS in Ground/Short-Circuit Fault)

  • 김진태;이승용;박상진;차한주;김수열
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권2호
    • /
    • pp.119-122
    • /
    • 2020
  • With recent ESS (Energy Storage System) fire accident, the fault protection performance is becoming more important. However, there has never been any experiments with the protection performance on the faults in the ESS system level. In this study, the effect of AC ground fault and IGBT (Insulated Gate Bipolar mode Transistor) short-circuit failure on MW class ESS was performed experimentally for the first time in the world. First of all, the effect of the AC single line ground fault on battery was analyzed. Moreover, the transient voltage was investigated as a function of the battery capacity and the power level. Finally, the breaking capability and insulation performance of ESS were examined under PCS short-circuit fault condition. Through the tests, it was found that ESS protection system safely blocked the faulty current regardless of the faults, whereas the electronic parts such as IGBT and MC (Magnetic Contactor) were broken by the fault current. Also, the electrical breakdown in ESS resulted from the transient voltage during the protection process.

SIMULINK를 이용한 CRW-type UAV 추진시스템의 동적 성능 모사에 관한 연구 (Dynamic Performance Simulation of the Propulsion System for the CRW-Type UAV Using SIMULINK)

  • 공창덕;박종하
    • 한국추진공학회지
    • /
    • 제8권4호
    • /
    • pp.76-83
    • /
    • 2004
  • CRW Tyre UAV 추진시스템은 수직으로 이착륙이 가능하고 고정익으로 고속 전진 비행이 가능한 개념으로 설계되었다. 이를 위해 추진시스템은 이착륙 시에는 로터를 구동시켜 수직으로 비행하고 고속 비행 시에는 로터를 정지시켜 날개로 사용하고 가스발생기에서 생성된 가스를 주 노즐로 분사하여 본래의 제트엔진으로 사용한다. ICV방법과 SIMULINK를 이용하여 천이 성능 해석을 수행하였다. 연료유량은 터빈 입구온도의 스텝과 과온 현상을 피하기 위해 램프 증가를 하였고 이에 따른 추력의 변화와 터빈 입구온도의 변화를 살펴보았다.

회전수 상승폭 변화에 따른 인버터열펌프의 비정상 운전특성 (A study on the transient characteristics during speed up of inverter heat pump)

  • 황윤제;김호영
    • 설비공학논문집
    • /
    • 제10권4호
    • /
    • pp.495-507
    • /
    • 1998
  • The transient characteristics of a 4.0㎾ inverter driven heat pump was investigated by theoretical and experimental studies. The heat pump used in this study consists of a high side scroll compressor and $\Phi$7 compact heat exchangers with two capillary tubes. A series of tests was peformed to examine the transient characteristics of heat pump in heating and cooling mode when the operating speed was varied from 30Hz to 102Hz. One of the major issues that has not been addressed so far is transient characteristics during speed modulation. A cycle simulation model has been developed to predict the cycle performance under frequency rise-up conditions, and the results of theoretical study were compared with the results of experimental study. The theoretical model was driven from mass conservation and energy conservation equations to predict the operation points of refrigerant cycle and the performances at various operating speeds. For transient conditions, the simulated results are in good agreement with the experimental results within 10%. The transient cycle migration of the liquid state refrigerant causes a significant dynamic change in system. Thus, the migration of refrigerant is the most important factor whenever An experimental analysis is performed or A simulation model is developed.

  • PDF