• Title/Summary/Keyword: Transient characteristics

Search Result 1,782, Processing Time 0.044 seconds

An Experimental Study on Unsteady Heat Transfer of Spray-Impinging Plate in a Pressurized Chamber (가압 분무실내 스프레이 충돌판에서 나타나는 비정상 열전달 측정에 관한 연구)

  • Cho, Chang-Kwun;Lee, Yeol;Koo, Ja-Ye
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.1
    • /
    • pp.60-67
    • /
    • 2000
  • An experimental investigation on transient heat transfer phenomena of impinging diesel-spray on a flat plate in a pressurized chamber is carried out. A diesel spray is injected from a single-hole nozzle and impinges to a heated flat plate in the chamber. A fast-response thermocouple installed in the top surface of the plate measures the transient variation of surface temperature of the plate under various conditions of the chamber pressures. Utilizing the semi-infinite model, the temporal variation of the heat flux on the plate is determined. Effects of various parameters, such as vertical distances between the nozzle and the plate, radial distances from the injection-axis, and the chamber pressures, on the heat flux characteristics of impinging diesel-spray are studied.

Measurement and Analysis of Knock for Rapid Throttle Opening in SI Engines (가솔린 엔진에서 급가속 운전시 노킹 측정 및 분석)

  • 이종화;박경석;김현용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.28-35
    • /
    • 1999
  • In this study, investigation of transient knock characteristics in a spark-ignition engine has been carried out. The universal knock threshold values were found by a DFDD method and a NSDBP method which is a non-dimensional version of the SDBP method. Also modified NSDBP method could be used for transient knock detection. In a commercial ECU , spark timing was retarded from the steady -state spark timing during rapid throttle opening to avoid uncomfortable feeling and knock. Knock usually occurred just after the start of rapid throttle opening when spark timing was set, as values for the steady state condition. We found that air/fuel ratio deeply involved with the knock during transient condition. Due to the difference of initial heat release rate, knock occurred more easily at rich air/fuel ratio than at lean air/fuel ratio.

  • PDF

Experimental Study on the Measurement Method of Heat Transfer Coefficients Using a Transient Liquid Crystal Technique (과도 액정 기법을 이용한 열전달 계수 측정법에 관한 실험적 연구)

  • 홍철현;정준화;양장식;이기백
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.581-588
    • /
    • 2003
  • Heat transfer characteristics of a pair of longitudinal vortices using a transient liquid crystal technique are studied experimentally. In order to control the strength of longitudinal vortices, angle of attack of the vortex generators is $20^{\circ}$and the length of space from the centerline the vortex generations is 25mm apart. The heat transfer measurements using a transfer coefficients. The following conclusions are obtained from the present experiment. When any vortex generators are not set up in wind tunnel test, heat transfer rate is low respectively. However, with the vortex generators of rectangular winglet, the heat transfer on the local surface can be enhanced.

Dynamic Analysis and Structural Safety Evaluation of the Cabinet of a Reactor Safety System (원자로 보호계통 캐비닛의 동해석과 구조 안전성 평가)

  • Lee, Boo-Youn;Cho, Chung-Rae;Kim, Won-Jin;Jeong, Dong-Gwan;Shon, Jae-Youl
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.12 s.177
    • /
    • pp.131-140
    • /
    • 2005
  • Responses of the cabinet of the reactor safety system under seismic leadings are analyzed, its dynamic characteristics and structural reliability being evaluated. Analyzed natural frequencies are compared with those measured from a resonance test. Structural safety of the cabinet is evaluated in consideration of the required response spectrums of the operation-base and safe-shutdown earthquakes. Transient responses of the cabinet are analyzed with input ground acceleration measured during the seismic test, accelerations being extracted at the locations of the main internal parts. The transient responses are compared with those from the seismic test, favorable results being shown.

Transient Recovery Voltage Analysis of industrial customer (대규모 수용가의 차단기 과도회복전압 해석)

  • Shin, Byoung-Yoon;Lee, Han-Sang;Jang, Gil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.320-321
    • /
    • 2011
  • As the scale of industries expands, the facilities of the industrial customer become larger and more complex. When a fault occurs in the system, the circuit breakers play an important role in minimizing causalitites by quickly tripping the faulted line. Since the capacity of the receiving-end has increased in size, an examination is needed to be performed between the industrial customers and the conventional circuit breakers. The transient recovery voltage, which is the initial transient characteristics of the voltage across the breaker when tripped, is an important factor in determining the circuit breaker's performance. In this paper, a TRV analysis on the large-scale industrial customer is being performed utilizing PSCAD/EMTDC.

  • PDF

Pulsed Energy Dependent Neutron Transport Theory

  • Minn, Hokee
    • Nuclear Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.249-254
    • /
    • 1970
  • A time-energy transient characteristics of pulsed neutron transport problem with an inelastic kernel in the fast domain is solved exactly with a continuous energy transfer operator. A discrete time eigenvalue is found which is asymptotically dominant. The complete solution consists of three parts: a time-energy separable mode which is asymptotically dominant and a non-separable mode which is made up by two parts; a pure energy slowing-down transient and a mixture of time and energy transient which is negligible asymptotically.

  • PDF

An Improved Battery Charging Algorithm for PV Battery Chargers (태양광 배터리 충전기를 위한 개선된 충전 알고리즘)

  • Kim, Jung-Hyun;Jou, Sung-Tak;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.507-514
    • /
    • 2013
  • In this paper, the proposed charging algorithm is converted from the charging mode to compensate the transient state in the solar battery charging system. The maximum power point tracking (MPPT) control methods and the various charging algorithms for the optimal battery charging are reviewed. The proposed algorithm has excellent transient characteristics compare to the previous algorithm by adding the optimal control method to compensate the transient state when the charging mode switches from the constant current mode to the constant voltage mode based on the conventional constant-current constant-voltage (CC-CV) charging algorithm. The effectiveness of the proposed method has been verified by simulations and experimental results.

Characteristics of Transient Ground Impedance of a Scaled Grounding Grid on the High Current Impulse (대전류 임펄스에 대한 소규모 메쉬전극의 과도접지임피던스 특성)

  • Lee, Tae-Hyung;Cho, Sung-Chul;Eom, Ju-Hong;Yoo, Yang-Woo;Lee, Bok-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1418_1419
    • /
    • 2009
  • This paper presents the transient impedance when high current impulse up to 5 kA is applied to a scaled grounding grid in test field. For a realistic analysis of transient impedance on the high current impulse in the ground systems, grounding electrode installed outdoors and impulse current generator was used. The results were discussed based on its voltage and current trace, impulse impedance and V-I curve.

  • PDF

Reduction of Transient Vibration on $H_2$ Piping System for Generator Cooling in a Power Plant (화력발전소 발전기 냉각용 수소배관계 과도진동 개선)

  • Yang, Kyeong-Hyeon;Kim, Sung-Hwi;Cho, Chul-Whan;Bae, Chun-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.588-592
    • /
    • 2002
  • There was the transient vibration on $H_2$ piping system for cooling the generator in a power plant. We found it was resulted from resonance between the natural vibration of the piping system and exciting force from the turbine rotor by measurement and simulation test. We verified it would be changed the mode shape of the piping system by several simulation test for the structural modification of the piping system. Therefore we concluded that the change of natural vibration mode depends on deeply changing effective length of pipe and reducing supports.

  • PDF

Computational Vibration and Characteristic Analyses for Tilt-Rotor Vehicle Considered 3-Dimensional Supporting Equipment Structures (탑재장비 3차원 지지구조 형상을 고려한 틸트로터 항공기 전산진동해석 및 특성분석)

  • Kim, Yu-Sung;Kim, Dong-Hyun;Kim, Dong-Man;Lee, Jung-Jin;Kim, Sung-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1000-1007
    • /
    • 2007
  • In this study, structural vibration analyses of a smart unmanned aerial vehicle (UAV) have been conducted considering dynamic hub-loads of tilt rotor. Practical computational structural dynamics technique based on the finite element method is applied using MSC/NASTRAN. The present UAV(TR-S5-04) finite element model is constructed as a full three-dimensional configuration with different fuel conditions and tilting angles for helicopter, transient and airplane flight modes. In addition, the 3-dimensional supporting equipment structures of electronic devices are considered for vibration analysis. As the results of this study, transient structural displacements and accelerations are presented in detail. Moreover, vibration characteristics of structural parts and installed equipments are investigated for different fuel conditions and tilting angles.

  • PDF