• 제목/요약/키워드: Transient analysis

검색결과 3,049건 처리시간 0.031초

비정상 상태의 선접촉 탄성유체윤활 유막두께 및 유막압력 특성연구 (Study on the Film Thickness and Pressure of the Transient Line Contact Elastohydrodynamic Lubrication)

  • 조재철;장시열
    • Tribology and Lubricants
    • /
    • 제25권5호
    • /
    • pp.335-341
    • /
    • 2009
  • Elastohydrodynamic lubrication (EHL) analysis shows that film thickness is very flat in the contact area and pressure distribution is somehow similar to that of Hertzian contact pressure except the outlet region with pressure spike. These typical patterns of EHL film thickness and pressure are the cases under the steady contact conditions of applied loads and speeds. However, many engineering contacts are rather under the conditions of varying loads and contact speeds, and therefore the predictions for endurance life and performance of machine elements with steady EHL analysis are not suitable in many occasions. This study shows the differences in film thickness formation and pressure distribution between steady and transient contact conditions in several contact cases.

Theoretical Analysis on Transient Torsional Vibrations of Two Stroke Low Speed Diesel Engines

  • Lee, Don-Chool;Kim, Sang-Hwan;Yu, Jung-Dae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권3호
    • /
    • pp.207-214
    • /
    • 2007
  • Theoretical analysis on transient torsional vibration was started from the early 1960s for high power synchronous motor application. Particularly. its simulation and measuring techniques in marine diesel engine field have been steadily studied by some classification societies and large marine diesel engine designers. This paper introduces the simulation method on transient torsional vibration of two stroke low speed diesel engine using the Newmark method.

지중송전계통에서 불평형 구성요소에 따른 과도현상 해석 및 평가 (Transient Phenomena Analysis and Estimation According to Unbalance Factors on Underground Power Cable Systems)

  • 정채균;이종범;강지원;이동일
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권8호
    • /
    • pp.410-417
    • /
    • 2005
  • This paper analyses the transient phenomena against single line to ground fault and lightning surge on underground power cable systems. For analysis in various fault conditions, several actual underground power cable systems are modeled using ATP In ground fault, the transient characteristic of the conductor and the sheath according to the fault current and the installation types of CCPU are analysed. In lightning surge strokes, the various unbalanced conditions including the length of crossbonded lead, the breakdown of CCPU and distance unbalance are considered. This paper is expected to contribute the establishment of proper protection methods against transients on underground power cable systems.

라비뇨방식 유성기어를 채택한 자동변속기의 변속과도특성 해석 (The analysis of the shift transient characteristics for the Ravigneaux type automatic transmission)

  • 김인찬;이승종
    • 대한기계학회논문집A
    • /
    • 제21권11호
    • /
    • pp.1943-1949
    • /
    • 1997
  • In this paper, the analysis of the shift transient characteristics for the Ravigneaux type automatic transmission has been carried out using dynamic models of the automatic trnasmission. It is necessary to understand the overall system including multi-plate clutch, band brake, one way clutch, and planetary gears. The equations of motion are derived from the dynamic models of the automatic transmission. The GUI computer simulation program has been developed to analyze the shift transient characteristics of the vehicle equipped with the Ravigneaux type automatic transmission.

압력섭동에 따른 비정상 화염편 응답특성 해석 (Flamelet Analysis for Transient Response to Pressure Oscillations)

  • 배준경;김용모;김성구
    • 한국연소학회지
    • /
    • 제16권1호
    • /
    • pp.30-35
    • /
    • 2011
  • This study has been mainly motivated to numerically investigate the transient flame response to pressure oscillations in the gaseous hydrogen - liquid oxygen flames at supercritical pressures. The present analysis is based on the real-fluid transient flamlet model and the flame field is acoustically perturbed only by the sinewave oscillations in the frequency range from 1,000 Hz to 5,000 Hz. Based on numerical results, the detailed discussions are made for the flame response characteristics and the transient flamelet response associated with the high-frequency combustion instability in the liquid propellant rocket engines.

고온 초전도체 관에서의 과도 자기확산 해석 (Analysis of Transient Magnetic Diffusion in a High-Temperature Superconductor Tube)

  • 설승윤;정성기
    • 한국전기전자재료학회논문지
    • /
    • 제15권11호
    • /
    • pp.991-996
    • /
    • 2002
  • Transient magnetic diffusion process in a melt-cast BSCCO-2212 tube is analyzed by an analytical method. The transient diffusion partial differential equation is transformed into an ordinary differential equation by integral method. The penetration depth of magnetic field into a superconducting tube is obtained by solving the differential equation numerically. The results show that the penetration depth as a function of time which is somewhat different from the results by Bean's critical state model. The reason of the difference between the present results and that of Bean's model is discussed and compared in this paper.

HVDC 송전망이 대형발전단지의 과도안정도에 미치는 영향 분석 (Analysis of Effect of HVDC Transmission System on the Transient Stability)

  • 전혁모;전영환
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.1-8
    • /
    • 2016
  • The characteristics of Korean power systems are large capacity of generation sites and concentrated load in Seoul metropolitan area. According to the national generation facility plan, more generation facilities are needed to be constructed as the electrical demands are forecasted to increase. Moreover, the size of generation sites are expected to increase, too. Therefore transient stability problems become worse and worse. Recently, the necessity of HVDC has been raised to overcome the difficulty of constructing HVAC transmission lines. This paper shows the analysis of transient stability when HVDC transmission system is added to the power system consisting of large generation sites.

부분구조의 상태방정식을 이용한 국부 비선형계의 과도응답해석 (Transient Response Analysis of Locally Nonlinear Structures Using Substructure-Based State Equations)

  • 김형근;박윤식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1993년도 춘계학술대회논문집; 한국과학연구소, 21 May 1993
    • /
    • pp.52-56
    • /
    • 1993
  • An efficient method is presented for determining transient responses of locally nonlinear structures using substructure eigenproperties and Lagrange multiplier technique. The method is based upon the mode synthesis formulation procedure, but does not construct the equations of motion of the combined whole structure compared with the conventional methods. For modal bases of each linear substructure, either fixed or free interface modes can be employed. The transient analysis is based upon the recurrence discrete-time state equations and offers the simplicity of the Euler integration method without requiring small time increment and iterative solution procedure. Numerical examples reveal that the method is very accurate and efficient in calculating transient responses compared with the direct numerical integration method.

  • PDF

실증시험을 통한 지중배전선로 모델링 기법 검증 연구 (Verification of Underground Distribution Line Modeling with Field Test)

  • 윤창섭;이재봉;김병숙;이종범
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2091-2097
    • /
    • 2007
  • This paper described the verification of modeling technique of underground distribution from comparison between field test and simulation. It needs more exact transient phenomenon analysis model to establish lightning protection of underground distribution line. Although, there were a lot of transient phenomenon researches, nobody could has verified the confidence of modeling from field tests in interior until now. So, simulation model verified field test is needed to analyse transient phenomenon of underground distribution system. The examination must be accomplished in many different condition before suggesting these verified analysis model. In this paper, the conditions were examined and the various data results on the different line composition was compared with the EMTP simulation, when the lightning impulse test was accomplished at underground distribution line. Also the value between field test and simulation was very closed and the method of modeling has demonstrated confidence, when the method is used to analyse domestic transient phenomenon of underground distribution.

단일추진제 추진시스템의 과도기유체 해석 (A fluid transient analysis for the propellant flow in a monopropellant propulsion system)

  • 채종원;한조영
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 춘계 학술대회논문집
    • /
    • pp.173-181
    • /
    • 2005
  • A fluid transient analysis for the propellant flow in a monopropellant propulsion system is conducted using the method of characteristics (MOC). Algebraic simultaneous equations method and Clamor's rule method utilized to drive the compatible and characteristic equations are reviewed to understand MOC more extensively. The identification of fluid transient phenomena of propulsion system of Koreasat 1 is carried out through parametric studies. Also this work describes the reason that the propulsion system of Koreasat 1 has no orifice to control flow transients or to limit the initial hydrazine flow rate for the first-pulse firing.

  • PDF