• Title/Summary/Keyword: Transient Recovery

Search Result 213, Processing Time 0.032 seconds

Development of new reclosing scheme considering the superconducting fault current limiter (초전도 한류기를 고려한 재폐로 차단기 동작 scheme 개발)

  • Ko, Yun-Tae;Seo, Hun-Chul;Rhee, Sang-Bong;Kim, Chul-Hwan;Kim, Jae-Chul;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.135_136
    • /
    • 2009
  • This paper proposes the new reclosing scheme considering the recovery time of SFCL in distribution systems which is based on variable dead time control. The main idea is that it uses the carrier signal to distinguish whether the fault is instantaneous or permanent following initial recloser opening. The system and SFCL is modeled by using Electromagnetic Transient Program(EMTP) and the validity of the reclosing scheme represented in this paper is analyzed according to the value of the fault resistance and the time of the fault removal.

  • PDF

The study on the oscillatory frequency and factor(γ) of transient recovery voltage (과도회복전압의 진동주파수와 진폭율에 대한 연구)

  • Kim, Geun-Yong;Sung, Ki-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.652_653
    • /
    • 2009
  • 주어진 조건 하에서 의도하는 기간 동안 요구된 기능을 적절하게 수행하기 위해서는 제품의 신뢰성 확보가 무엇보다도 중요하다. 신뢰성 확보를 위해서는 제품의 안전성 및 내구성에 대한 고려가 충분히 이루어져야 한다. 고빈도 개폐를 목적으로 사용되는 전자기 접촉기 또한 제품의 안전성 및 성능의 신뢰성이 중요한 제품이라 할 수 있다. 그래서 이를 검증하기 위한 전자기 접촉기의 부하개폐동작성능에 대한 평가가 중요한 시험항목으로 부각되고 있다. 그리고 개폐특성을 평가하기 위한 부하는 규정된 과도회복전압특성을 얻을 수 있도록 조정되어야 한다. 본 논문에서는 부하측 중성점 접지 방식의 부하 회로 조정방법을 사용하여 전자기 접촉기의 개폐성능을 평가하기 위한 과도회복전압의 진동주파수와 진폭율의 특성을 고찰하였다.

  • PDF

The prospective TRV analysis of 345KV transmission system (345 KV 송전계통의 고유 TRV 해석)

  • Yoon, Jae-Young;Jung, Wee-Sik;Park, Dong-Wook;Min, Suk-Won;Jung, Sang-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.397-400
    • /
    • 1989
  • The interrupting capability of circuit breaker to have an effect on stability and reliability of the power system is largely determined by the fault current and prospective TRV (prospective transient recovery voltage). The prospective TRV, which is essentially a system function determined by the elements of the connected circuit, is not constant for a given system location but is affected by a number of variables. Therefore, the purpose of this study is to analyze the prospective TRV of KEPCO's 345KV transmission system by using EMTP (Electro-Magnetic Transients Program) and to compare the calculated values with the standard values in KSB 150 (1976)

  • PDF

A Study on Optimization of the Weil-Dobkes Synthetic Short-Circuit Tests (Weil-Dobke 합성단락시험로의 최적화 연구)

  • 김맹현;고희석
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.6
    • /
    • pp.287-292
    • /
    • 2001
  • This paper deals with the configuration, operating principles, systematic calculation method of parameter and optimization method of test circuit for parallel current injection method, series voltage injection method and hybrid synthetic test method as the method for performance test of circuit breaker with extra high interrupting capacity. The test method depicted above is applied to short-circuit making and breaking test (operating sequence :Os CdOs, Od-CdOs) and out-of-phase tests(operating sequence :Os, CdOs) for performance test of the newly-developed 420kV, 50kA and 800kV 50kV puffer-type gas circuit-breaker according to IEC 60056 and IEC 60427. The testing results, evaluation of equivalence for test and analyzed results are also presented in this paper.

  • PDF

A Study on DC Circuit Breaker using SCR Chung Hoo Park (SCR 에 의한 직류회로차단기의 과부하차단특성개선)

  • 박정후
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.2
    • /
    • pp.89-95
    • /
    • 1978
  • A SCR static breaker was studied on the Resistive and inductive load, then on the overload break circuit using operational Amplifier. In this paper, the principal circuit required for forced commutation was voltage commutation by the introduction of a parallel Capacitor. The results obtained are follows; 1. In thecondition that the tima constant of R-C circuit is larger than the turn off time of SCR, the breaker has low transient phenomena and no recovery vol age. 2. By using OP Amplifier on the load circuit, overcurrent trip point will be able to adjust to the wide range of over current. 3. In the over current qrcuit, the power loss was reduced remarkably.

  • PDF

Determination of Optimal Checkpoint Interval for Real-time Control Tasks Considering Performance Index Function (성능 함수를 고려한 실시간 제어 테스크에서의 최적 체크 포인터 구간 선정)

  • Kwak, Seong-Woo;Jung, Young-Joo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.875-880
    • /
    • 2008
  • In this paper, a novel method to determine the optimal checkpoint interval for real-time control task is proposed considering its performance degradation according to tasks's execution time. The control task in this paper has a specific sampling period shorter than its deadline. Control performance is degraded as the control task execution time is prolonged across the sampling period and eventually zero when reached to the deadline. A new performance index is defined to represent the performance variation due to the extension of task execution time accompanying rollback fault recovery. The procedure to find the optimal checkpoint interval is addressed and several simulation examples are presented.

A Study for Analysis of Transient Recovery Voltage and Control method of Circuit Breaker According to the Load condition (부하에 따른 차단기 극간의 과도회복전압 분석 및 제어기법)

  • Park, Sung-Tae;Kim, Hyoun-Su;Rhee, Sang-Bong;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.253-254
    • /
    • 2008
  • 본 논문에서는 계통 부하에 따른 차단기의 최적 개폐시점 선정을 위해 지상 및 진상 부하별 과도회복전압 발생 추이를 분석하였다. 또한 모선 전압의 위상 변화에 따라 차단기의 개극 시점 변화를 통해 발생되는 과도 회복전압의 파형을 분석하여 최적의 개폐 시점 추정을 EMTP(Electro-Magnetic Transients Program) 시뮬레이션 결과로 얻고 부하에 따른 차단기 개폐 제어 방법에 대해 분석하였다.

  • PDF

A Study on the Performance Enhancement of HVDC System Using Hybrid Filter and Energy Recovery Filter (11차/13차 고조파를 동시에 제거하는 Single Tuned 필터)

  • Kim C.K.;Yang B.M.;Jeong G.J.;Ahan J.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.717-721
    • /
    • 2003
  • Two non-conventional HVDC converter arrangements are compared. These include the Capacitor Commutated Converter (CCC) in which series capacitors are included between the converter transformer and the valves, and the Controller Series Capacitor Converter (CSCC), based on more conventional topology, in which series capacitors are inserted between the AC filter bus and the AC network. Results show that both options have comparable steady state and transient performance. Danger of ferroresonance with the CSCC option is eliminated by controlling the amount of series compensation. The dynamic performance simulations is peformed by PSCAD/EMTDC

  • PDF

The Optimal Circuit Condition Selection for Cable Charging Current Test by IEC60265-1 (IEC60265-1에 의한 케이블 충전전류 시험을 위한 최적 회로 조건 선정)

  • Kim, K.D.;Hur, Y.S.;Yun, J.H.;Lee, H.C.;Ham, G.H.;Park, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.264-266
    • /
    • 2001
  • We must consider resistance capacitance and their circuit connection condition for cable charging current test by IEC60265-1. According to their values and circuits, the ratio of applied voltage and transient recovery voltage are much different. This paper is convinced of TRV waves and proposes the optical circuit required at the standard via the simulation of all circuit conditions.

  • PDF

Brachial Plexus Injury as a Complication after Nerve Block or Vessel Puncture

  • Kim, Hyun Jung;Park, Sang Hyun;Shin, Hye Young;Choi, Yun Suk
    • The Korean Journal of Pain
    • /
    • v.27 no.3
    • /
    • pp.210-218
    • /
    • 2014
  • Brachial plexus injury is a potential complication of a brachial plexus block or vessel puncture. It results from direct needle trauma, neurotoxicity of injection agents and hematoma formation. The neurological presentation may range from minor transient pain to severe sensory disturbance or motor loss with poor recovery. The management includes conservative treatment and surgical exploration. Especially if a hematoma forms, it should be removed promptly. Comprehensive knowledge of anatomy and adept skills are crucial to avoid nerve injuries. Whenever possible, the patient should not be heavily sedated and should be encouraged to immediately inform the doctor of any experience of numbness/paresthesia during the nerve block or vessel puncture.