• 제목/요약/키워드: Transient Method

검색결과 2,572건 처리시간 0.03초

Development and verification of PWR core transient coupling calculation software

  • Li, Zhigang;An, Ping;Zhao, Wenbo;Liu, Wei;He, Tao;Lu, Wei;Li, Qing
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3653-3664
    • /
    • 2021
  • In PWR three-dimensional transient coupling calculation software CORCA-K, the nodal Green's function method and diagonal implicit Runge Kutta method are used to solve the spatiotemporal neutron dynamic diffusion equation, and the single-phase closed channel model and one-dimensional cylindrical heat conduction transient model are used to calculate the coolant temperature and fuel temperature. The LMW, NEACRP and PWR MOX/UO2 benchmarks and FangJiaShan (FJS) nuclear power plant (NPP) transient control rod move cases are used to verify the CORCA-K. The effects of burnup, fuel effective temperature and ejection rate on the control rod ejection process of PWR are analyzed. The conclusions are as follows: (1) core relative power and fuel Doppler temperature are in good agreement with the results of benchmark and ADPRES, and the deviation between with the reference results is within 3.0% in LMW and NEACRP benchmarks; 2) the variation trend of FJS NPP core transient parameters is consistent with the results of SMART and ADPRES. And the core relative power is in better agreement with the SMART when weighting coefficient is 0.7. Compared with SMART, the maximum deviation is -5.08% in the rod ejection condition and while -5.09% in the control rod complex movement condition.

과도 안정도를 고려한 가용송전용량(ATC) 계산에 관한 연구 (A Study on The Available Transfer Capability(ATC) with Transient Stability Constraints)

  • 김양일;정성원;김재현
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.437-443
    • /
    • 2009
  • In recent years, electric power systems have been experiencing a rapid change due to the increasing electricity market. For the effective use of power system under the deregulated environment, it is important to make a fast and accurate calculation of the maximum available transfer capability (ATC) from a supply point to a demand point. In this paper, the purpose of this research is to calculate ATC fast and accurately for securing the stability of system and raising the efficiency as a result of anticipating transmission congestion according to transmission open access progressed in the future under the regulated environment of electricity market. In this paper, a study utilized a relation of the potential energy and energy function by which calculated CCT and then utilized a relation of PEBS for transient stability ATC calculation. In this paper, ATC was calculated as RPF and Energy Function method and calculation results of each method was compared. Contingence ranking method decided the weak bus by the Eigenvalues of Jacobian matrix and overloading branches by PI-index. As a result, a study proved the fast and accurate ATC calculation method considering transient stability suggested in this paper. Through the case study using New England 39 bus system, it is confirmed that the proposed method can be used for real time operation and the planning of electric market.

TRANSIENT ANALYSIS OF A QUEUEING SYSTEM WITH MARKOV-MODULATED BERNOULLI ARRIVALS AND OVERLOAD CONTROL

  • Choi, Doo-Il
    • Journal of applied mathematics & informatics
    • /
    • 제15권1_2호
    • /
    • pp.405-414
    • /
    • 2004
  • This paper considers overload control in telecommunication networks. Markov-modulated Bernoulli process ( MMBP ) has been extensively used to model bursty traffics with time-correlation. Thus, we investigate the transient behavior of the queueing system MMBP/D/l/K queue with two thresholds. The model is analyzed recursively by using the generating function method. We obtain the transient queue length distribution and waiting time distribution at an arbitrary time. The transient behavior of the queueing system helps observing the temporary system behavior.

Characteristics of Transient Overvoltages for the Towers with Time Varying Tower Footing Resistance

  • Kwak, Hee-Ro
    • 대한전기학회논문지
    • /
    • 제33권3호
    • /
    • pp.118-124
    • /
    • 1984
  • This paper investigated the characteristics of transient overvoltages on the tower caused by time varying tower footing resistance in the path of lightning stroke current entering earth on transmission lines. The tower with time varying tower footing resistance was simulated and the transient overvoltageson the tower due to lightning stroke current were computer by Nodal Solution Method. From the results, it was found that the determination of the steady state values as a limit of inductive tower footing resistance causes higher transient overvoltages than CFO voltages of insulator strings and V-T characteristics of the insulator strings should be considered for computation of backflashover rate.

  • PDF

유동계 내 집속체의 과도적 거동에 따른 출력 불균제 해석 (Analysis of Output Irregularity from the Transient Behavior of Bundle in a Flow Field)

  • 허유;김종성
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.965-968
    • /
    • 2005
  • Roll drafting operation causes variations in the linear density of bundles because the bundle flow cannot be controlled completely by roll pairs. Defects occurring in this operation bring about many problems successively in the next processes. In this paper, we attempt to analyze the draft dynamics and the linear density irregularity based on the governing equation of a bundle motion that has been suggested in our previous studies. For analyzing the dynamic characteristics of the roll drafting operation, it is indispensable to investigate a transient state in time domain before the bundle flux reaches a steady state. However, since governing equations of bundle flow consisting of continuity and motion equations turn out to be nonlinear, and coupled between variables, the solutions for a transient state cannot be obtained by an analytical method. Therefore, we use the Finite Difference Method(FDM), particularly, the FTBS(Forward-Time Backward-Space) difference method. Then, the total equations system yields to an algebraic equations system and is solved under given initial and boundary conditions in an iterative fashion. From the simulation results, we confirm that state variables show different behavior in the transient state; e.g., the velocity distribution in the flow field changes more quickly the linear density distribution. During a transient flow in a drafting zone, the output irregularity is influenced differently by the disturbances, e.g., the variation in input bundle thickness, the drafting speed, and the draft ratio.

  • PDF

유한요소법과 등가회로법의 결합을 이용한 인버터 구동 3상 농형 유도전동기의 과도 특성 해석 (Transient Analysis of Inverter-fed Three Phase Squirrel Cage induction Motor Using A Combined Method of Finite Element Method and Equivalent Circuit)

  • 조용;권병일;김재우;김병택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.805-807
    • /
    • 2002
  • In this paper, a method for an accurate and fast transient analysis, which employs a single slot model for the rotor, is presented. The equivalent circuit parameters are extracted from a combined method of F. E. M and equivalent circuit on 1 slot rotor boundary condition. Two kinds of circuit parameters for each slip are applied to equivalent circuit controlled by variable-voltage variable- frequency. One is the constant parameters at rated speed, and the other is the parameters varying in accordance with slip-frequency. The computer characteristics of the suggested method for four-pole 1.5KW induction motor are compared with those of Equivalent circuit for the transient analysis.

  • PDF

A Nonlinear Analytic Function Expansion Nodal Method for Transient Calculations

  • Joo, Han-Gyu;Park, Sang-Yoon;Cho, Byung-Oh;Zee, Sung-Quun
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.79-86
    • /
    • 1998
  • The nonlinear analytic function expansion nodal (AFEN) method is applied to the solution of the time-dependent neutron diffusion equation. Since the AFEN method requires both the particular solution and the homogeneous solution to the transient fixed source problem, the derivation solution method is focused on finding the particular solution efficiently. To avoid complicated particular solutions, the source distribution is approximated by quadratic polynomials and the transient source is constructed such that the error due to the quadratic approximation is minimized. In addition, this paper presents a new two-node solution scheme that is derived by imposing the constraint of current continuity at the interface corner points. The method is verified through a series of applications to the NEACRP PWR rod ejection benchmark problem.

  • PDF

A boundary element method based on time-stepping approximation for transient heat conduction in anisotropic solids

  • Tanaka, Masa;Matsumoto, T.;Yang, Q.F.
    • Structural Engineering and Mechanics
    • /
    • 제4권1호
    • /
    • pp.61-72
    • /
    • 1996
  • The time-stepping boundary element method has been so far applied by the authors to transient heat conduction in isotropic solids as well as in orthotropic solids. In this paper, attempt is made to extend the method to 2-D transient heat conduction in arbitrarily anisotropic solids. The resulting boundary integral equation is discretized by means of the boundary element with quadratic interpolation. The final system of equations thus obtained is solved by advancing the time step from the given initial state to the final state. Through numerical compuation of a few examples the potential usefulness of the proposed method is demonstrated.

상-파넬 히-팅의 해석법 (Steady and Transient Solution of heat Conduction from hurried Pipes of panel heating Slab)

  • 이건
    • 대한설비공학회지:설비저널
    • /
    • 제3권3호
    • /
    • pp.185-190
    • /
    • 1974
  • Floor panel heating system is popular in Korea as dwelling house heating system. There are two methods for keeping floor surface warm. One method is delivering warm air under the floor such as Roman Hypocaust and Korean traditional Ondol. The other method is imbedding hot water pipes into the concrete floor slab. This paper gives basic equations for steady and transient solutions of heat conduction from hurried pipes. For steady-state solution, fin Efficiency Method and Sink and Source Method were introduced. Sink and Source Method is applied to transient state and basic solution is given in the form of Exponential Integral Function. Numerical solutions can be solved easily by digital computer from these equations.

  • PDF

Transient Critical Heat Flux Under Flow Coastdown in a Vertical Annulus With Non-Uniform Heat Flux Distribution

  • Moon, Sang-Ki;Chun, Se-Young;Park, Ki-Yong;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • 제34권4호
    • /
    • pp.382-395
    • /
    • 2002
  • An experimental study on transient critical heat flux (CHF) under flow coastdown has been performed for the water flow in a non-uniformly heated vertical annulus under low flow and a wide range of pressure conditions. The objectives of this study are to systematically investigate the effect of the flow transient on the CHF and to compare the transient CHF with steady-state CHF The transient CHF experiments have been performed for three kinds of flow transient modes based on the coastdown data of a nuclear power plant reactor coolant pump. At the same inlet subcooling, system pressure and heat flux, the effect of the initial mass flux on the critical mass flux can be negligible. However, the effect of the initial mass flux on the time-to- CHF becomes large as the heat flux decreases. The critical mass flux has the largest value for slow flow reduction rate. There is a pressure effect on the ratio of the transient CHF data to steady-state CHF data. Except under low system pressure conditions, the flow transient CHF was revealed to be conservative compared with the steady-state CHF data. Bowling CHF correlation and thermal hydraulic system code MARS show promising results for the prediction of CHF occurrence .