• 제목/요약/키워드: Transient Components

검색결과 337건 처리시간 0.035초

WIGNER-VILLE INTERPRETATION OF MUSICAL SOUND AND TRANSIENT VIBRATION SIGNALS

  • Kim, Yang-Hann;Park, Yon-Kyu
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.752-757
    • /
    • 1994
  • Very often, one would like to have visual image of mechanical or acoustical events such as musical sound and transient vibrations. Conventional methods to visualize the signal, such as power spectrum, do not normally allow to cultivate the signal of interests due to their inherent limitation on transient signals. Other than the conventional method, one could use an instantaneous frequency which can reveal the variation of frequency in terms of time. Nevertheless it is quite sensitive to noise and can not resolve the frequency components of signals; normally produces additional components other than those of the signals. In this paper, we introduce the Wigner-Ville spectrum to see the transient characteristics of signal, especially musical sound and transient mechanical vibration signatures. For musical sound, several popular western classic music have been selected for the analysis. For the transient mechanical signature, the signals obtained from the car door experiment and the beam experiment are interpreted in terms of Wigner-Ville spectrum. Results demonstrate the visual expressions of transient signals; musical sound and vibrations.

  • PDF

반도체 스위칭소자의 내성특성 개선에 관한 연구 (A Study on the Immunity Improvement of Semiconductor Switching Components)

  • 민경찬;김동일
    • 한국항해학회지
    • /
    • 제21권3호
    • /
    • pp.75-81
    • /
    • 1997
  • 현재 자동차나 선박등에 사용하는 직류모터 속도 제어용 스위칭 소자는 스위칭 과전압으로 인하여 때때로 손상되거나 오작동을 일으키기쉽다. 본논문은 dc 모터 제어용 반도체 스위칭소자의 내성특성을 개선한 것이다. 이를 위하여, 먼저 저전압 보호소자인 비리스터나 제너 다이오드 등 가운데에서 스위칭 과전압에 대해 내성을 갖는 이상적인 소자를 선택하기 위해 과전압 보호자의 등가회로를 분석 하였다. 나아가서 국제규정에서 정의된 의사 과전압 파형의 적절한 선택, 스위칭 소자의 손상과정과 손상원인을 규명하고, 순시과전압 전류의 변화에 따른 각각의 임피던스 조건을 고려하여 직류모터 제어용 반도체 스위칭 소자의 내성특성 개선하였다.

  • PDF

Assessment of Corrosion Rate of Reinforcing Steel in Concrete Using Galvanostatic Pulse Transient Technique

  • So, Hyoung-Seok;Millard, Stephen Geoffrey
    • International Journal of Concrete Structures and Materials
    • /
    • 제1권1호
    • /
    • pp.83-88
    • /
    • 2007
  • This paper discusses a method of measuring transient potential response of a corrosion interface to a small galvanostatic pulse perturbation for a rapid assessment of the corrosion rate of reinforcing steel in concrete structures. Measurements were taken on 100 mm sections of steel bars which were subjected to a wide range of corrosion conditions, from passive steel to actively corroding steel. The duration of the applied galvanostatic pulse was varied between 5s and 180s, and the lateral distance of the point of measurement on the steel bar varied from zero to 400 mm. The result of the electrochemical transient response was investigated using a typical sampling rate of 1 kHz. Analysis of the transient potential response to the applied galvanostatic pulse has enabled the separation of equivalent electronic components so that the components of a series of capacitances and resistances, whose values are dependent on the corrosion condition of the reinforcing steel, could be isolated. The corrosion rate was calculated from a summation of the separate resistive components, which were associated with the corrosion interface, and was compared with the corrosion rate obtained from linear polarization resistance (LPR) method. The results show that the galvanostatic pulse transient technique enables the components of the polarization resistance to be evaluated separately so as to give more reliable corrosion rate values than those obtained from the LPR method. Additionally, this paper shows how the galvanostatic pulse transient response technique can be implemented. An appropriate measurement time for passive and actively corroding reinforcing steel is suggested for the galvanostatic pulse transient response measurements in the field site.

Conductive adhesive with transient liquid-phase sintering technology for high-power device applications

  • Eom, Yong-Sung;Jang, Keon-Soo;Son, Ji-Hye;Bae, Hyun-Cheol;Choi, Kwang-Seong
    • ETRI Journal
    • /
    • 제41권6호
    • /
    • pp.820-828
    • /
    • 2019
  • A highly reliable conductive adhesive obtained by transient liquid-phase sintering (TLPS) technologies is studied for use in high-power device packaging. TLPS involves the low-temperature reaction of a low-melting metal or alloy with a high-melting metal or alloy to form a reacted metal matrix. For a TLPS material (consisting of Ag-coated Cu, a Sn96.5-Ag3.0-Cu0.5 solder, and a volatile fluxing resin) used herein, the melting temperature of the metal matrix exceeds the bonding temperature. After bonding of the TLPS material, a unique melting peak of TLPS is observed at 356 ℃, consistent with the transient behavior of Ag3Sn + Cu6Sn5 → liquid + Cu3Sn reported by the National Institute of Standards and Technology. The TLPS material shows superior thermal conductivity as compared with other commercially available Ag pastes under the same specimen preparation conditions. In conclusion, the TLPS material can be a promising candidate for a highly reliable conductive adhesive in power device packaging because remelting of the SAC305 solder, which is widely used in conventional power modules, is not observed.

액체로켓엔진 천이작동 예측을 위한 구성품 동특성 모델링 (Modeling of Liquid Rocket Engine Components Dynamics at Transient Operation)

  • 김형민;이국진;윤웅섭
    • 한국추진공학회지
    • /
    • 제15권1호
    • /
    • pp.35-44
    • /
    • 2011
  • 액체로켓엔진 시스템의 시동 및 정지 또는 추력 제어와 같은 천이 작동 시 동특성을 예측하기 위한 선행 연구로서 추진제 공급 시스템의 구성품에 대한 동특성 모델링을 수행하였다. 연료 공급 계통과 산화제 공급 계통의 구성품들은 재생냉각채널을 제외하고 같은 것으로 가정하였다. 동특성 모델링의 대상 구성품은 펌프, 관로, 오리피스, 제어 밸브, 재생냉각채널, 인젝터 등이며 실제 엔진 시스템의 축소 모형에 대한 수류시험을 통해 각 구성품의 동특성 모델링을 검증하였다. 수치적인 방법을 바탕으로 구성품에 대한 동특성 모델링을 통합하였으며 축소 모형으로 연결된 수류시스템을 사용한 수류시험을 통해 통합 동특성 예측프로그램을 검증하였다.

과도성분과 상태도를 이용한 거리 계전기의 향상된 Zone 3 알고리즘 (An Enhanced Zone 3 Algorithm of a Distance Relay using Transient Components and State Diagram)

  • 허정용;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권3호
    • /
    • pp.161-167
    • /
    • 2004
  • Zone 3 of the distance relay is used to provide the remote back-up protection in case of the failure of the primary protection. However, the risk lot mal-operations under stressed conditions such as heavy loading, voltage and transient instability is usually high. Zone 3 is used in combination with the derivatives of the voltage, and current, etc to prevent mal-operations. Sometimes, the impedance characteristics that restrict the tripping area of relay are used to avoid the mal-operations due to load encroachment. This paper presents a novel Zone 3 scheme based on combining the steady-state components (i.e. 60Hz) and the transient components (TCs) using a state diagram that visualizes the sequence of studies that emanate from the sequence of events. The simulation results show that the novel zone 3 distance relay elements using the proposed method operates correctly for the various events.

프로니해석법을 이용한 공진 주파수 검출 알고리즘 (Oscillation Frequency Detecting Technique for Transmission Line Protection using Prony's Analysis)

  • 조경래;김성수;박종근;홍준희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.509-512
    • /
    • 1995
  • The relaying algorithm to calculate the fault distance from only transient signal at faults in T/L is presented. In this paper. At faults the oscillation frequency components exist in both voltage and current and these components minimize the input impedance shown in fault point. The equivalent source impedance shown in relaying point is needed to calculate the fault distance using these components. To source impedance, the reflection coefficient between forward wave and backward and the Prony's analysis is also employed to extract the oscillation frequency component from transient signals. The case study show that the new distance relaying algorithm satisfies the high operation speed and high accuracy even if the algorithm uses only transient signals.

  • PDF

신경회로망을 이용한 과도파형의 기본파성분 추출에 관한 연구 (A Study on the Extraction of Fundamental Frequency Components in the Transient Wave Signals Using Artificial neural networks)

  • 신명철;이복구
    • 대한전기학회논문지
    • /
    • 제43권4호
    • /
    • pp.553-563
    • /
    • 1994
  • This paper presents a filtering method using neural networks to extract fundamental frequency components of the transient wave signals in power systems. Based on the ability of multilayer feedforward neural networks to approximate any continuous function, a neural networks mapping filter is proposed for the protective distance relaying systems to extract the effective components efficiently. A characteristic feature of this mapping filter is composed of the multilayer perceptron neural networks which are trained by using random signals and those are mapped to the DFT filtering computational structure by GDR(Generalized Delta Rule). The advantage of this approach is demonstrated by the random waves and the fault transient wave signals of EMTP(electromagnetic transients program) in power systems fault conditions. The proposed method is compared with the conventional method and the simulation results show the efficiency of the neural networks.

  • PDF

과도성분과 상태도를 이용한 거리 계전기의 향상된 Zone 3 알고리즘 (An Enhanced Zone 3 Algorithm of a Distance Relay using Transient Components and State Diagram)

  • 허정용;김철환;박남옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.245-247
    • /
    • 2003
  • Zone 3 of the distance relay is used to provide the remote back-up protection in case of the failure of the primary protection. However, the risk for mal-operations under stressed conditions such as heavy loading, voltage and transient instability is usually high. Zone 3 is used in combination with the derivatives of the voltage, and current, etc to prevent mal-operations. Sometimes, the impedance characteristics that restrict the tripping area of relay are used to avoid the mal-operations due to load encroachment. This paper presents a novel zone 3 scheme based on combining the steady-state components(i.e. 60Hz) and the transient components(TCs) using a state diagram that visualizes the sequence of studies that emanate from the sequence of events. The simulation results show that the novel zone 3 distance relay elements using the proposed method operates correctly for the various events.

  • PDF

비정상과정에서 자동차 에어컨의 증발기 및 응축기의 컴퓨터 시뮬레이션 (Transient Computer Simulation of Evaporation and Condenser in an Automotive Air-Conditioning System)

  • 오상한;신동우;원성필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.19-24
    • /
    • 2000
  • The objective of this study is to develope a computer simulation model and estimate theoretically the transient performance characteristics of heat exchangers in an automotive air-conditioning system. To do that, the mathematical modelling of heat exchangers, such as evaporator and condenser, is presented first of all. For detail calculation, evaporator and condenser are divided into many sub-sections. Each sub-section is an elemental volume for transient modelling. The elemental volume is assumed to consist of three components, refrigerant, tube with fin, and air, and various properties including temperatures of three components are determined step along sub-sections. The properties of refrigerant R134a and air are calculated directly in the program. The heat transfer coefficients and pressure drop in single or two phase are also calculated by suitable empirical correlations. The overall tendencies of the simulation results were agreed well with those of actual situation.

  • PDF