• Title/Summary/Keyword: Transient Behavior

Search Result 733, Processing Time 0.03 seconds

A Study on the Prediction of Plate Temperature in Indirectly-Fired Continuous Heat Treatment Furnace (간접 가열방식의 연속식 열처리로내 판(Plate) 온도해석에 관한 연구)

  • Kim Young-Deuk;Kang Deok-Hong;Kim Woo-Seung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.6 s.249
    • /
    • pp.514-522
    • /
    • 2006
  • This study has been performed to predict the transient thermal behavior of the plate in indirectly-fired continuous heat treatment furnace. The temperature profiles in the plate are determined solving the transient one-dimensional heat conduction equations. To verify the validity of the present numerical results, the present results obtained from the transient analysis are compared with those of experiments. Extensive parametric investigations are performed to examine the effects of the emissivities of the plate and refractory, plate thickness and velocity, as well as the gas temperature, on the thermal behavior of the plate.

Improved Circuit Model for Simulating IGBT Switching Transients in VSCs

  • Haleem, Naushath Mohamed;Rajapakse, Athula D.;Gole, Aniruddha M.
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1901-1911
    • /
    • 2018
  • This study presents a circuit model for simulating the switching transients of insulated-gate bipolar transistors (IGBTs) with inductive load switching. The modeling approach used in this study considers the behavior of IGBTs and freewheeling diodes during the transient process and ignores the complex semiconductor physics-based relationships and parameters. The proposed circuit model can accurately simulate the switching behavior due to the detailed consideration of device-circuit interactions and the nonlinear nature of model parameters, such as internal capacitances. The developed model is incorporated in an IGBT loss calculation module of an electromagnetic transient simulation program to enable the estimation of switching losses in voltage source converters embedded in large power systems.

Heat transfer characteristics of redan structure in large-scale test facility STELLA-2

  • Yoon, Jung;Lee, Jewhan;Kim, Hyungmo;Lee, Yong-Bum;Eoh, Jaehyuk
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1109-1118
    • /
    • 2021
  • The construction of STELLA-2 facility is on-going to demonstrate the safety system of PGSFR and to provide comprehensive understanding of transient behavior under DBEs. Considering that most events are single-phase natural circulation flow with slow transient, STELLA-2 was designed with reduced-height of 1/5 length scale. The ratio of volume to surface area in the vessel can relatively increase resulting in excessive heat transfer. Therefore, a steady-state thermal-hydraulic analysis was performed and the effect of design change to reduce the heat transfer through redan was investigated. The heat transfer through single wall redan in STELLA-2 was 3% of the core power, comparable to 1% of the core power in PGSFR. By applying the insulated redan, about 70% of decrease effect was observed. The effect on transient behavior was also evaluated. The conclusion of this study was directly applied to the STELLA-2 design and the modified version is under construction.

Transient behavior of cryogenic thermosiphon working with R14 and nitrogen mixture (R14와 질소 혼합유체를 사용하는 극저온 열사이펀의 과도상태 거동)

  • Lee, Ji-Sung;Jeong, Sang-Kwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.1
    • /
    • pp.66-70
    • /
    • 2010
  • The operational temperature range of thermosiphon is generally limited from the critical point to the triple point of the working fluid to maintain two-phase state. Thermosiphon with mixed working fluid has a potential to widen the operational temperature range. In this study, the physical behavior of mixed working fluid during the transient operation of thermosiphon was analyzed with temperature-mole fraction diagram. The condenser and the evaporator temperature variations were explained by the dew line and the bubble line of the mixture. It is encouraging that the thermosiphon operation commences early with larger fraction of high boiling point component, but the temperature gap between the condenser and the evaporator due to the separation of two components has a negative effect on the officient cool down process.

Numerical Studies of Transient Opposed-Flow Flames using Adaptive Time Integration

  • Im, Hong-Geun
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.103-112
    • /
    • 2000
  • Numerical simulations of unsteady opposed-flow flames are performed using an adaptive time integration method designed for differential-algebraic systems. The compressibility effect is considered in deriving the system of equations, such that the numerical difficulties associated with a high-index system are alleviated. The numerical method is implemented for systems with detailed chemical mechanisms and transport properties by utilizing the Chemkin software. Two test simulations are performeds hydrogen/air diffusion flames with an oscillatory strain rate and transient ignition of methane against heated air. Both results show that the rapid transient behavior is successfully captured by the numerical method.

  • PDF

Dynamic performance prediction of a Supercritical oil firing boiler - Load Runback simulation in a 650MWe thermal power plant (초임계 오일 연소 보일러의 동특성 예측 연구 - 650MWe급 화력발전소의 Load Runback 모사)

  • Yang, Jongin;Kim, Jungrae
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.19-20
    • /
    • 2014
  • Boiler design should be desinged to maximize thermal efficiency of the system under imposed load requirement and a boiler should be validated for transient operation. If a proper prediction is possible on the transient behavior and transient characteristics of a boiler, one may asses the performance of boiler component, control logics and operation procedures. In this work, dynamic modeling method of boiler is presented and dynamic simulation of load runback scenario was carried out on suprecritical oil-firing boiler.

  • PDF

Dynamic Behavior of Oxide and Nitride LMR Cores during Unprotected Transients

  • Na, Byung-Chan;Dohee Hahn
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.489-494
    • /
    • 1997
  • A comparative transient analyses were performed for oxide and nitride cores or a large (3000 MWt), pool-type, liquid-metal-cooled reactor (LMR). The study was focused on three representative accident initiators with failure to scram : the unprotected loss-of-flow (ULOF), the unprotected transient overpower (UTOP), and the unprotected fast transient overpower (UFTOP). The margins to fuel melting and sodium boiling have been evaluated for these representative transients. The results show that there is an increase in safety margin with nitride core which maintains the physical dimensions of the oxide core.

  • PDF

Transient Diagnosis and Prognosis for Secondary System in Nuclear Power Plants

  • Park, Sangjun;Park, Jinkyun;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1184-1191
    • /
    • 2016
  • This paper introduces the development of a transient monitoring system to detect the early stage of a transient, to identify the type of the transient scenario, and to inform an operator with the remaining time to turbine trip when there is no operator's relevant control. This study focused on the transients originating from a secondary system in nuclear power plants (NPPs), because the secondary system was recognized to be a more dominant factor to make unplanned turbine-generator trips which can ultimately result in reactor trips. In order to make the proposed methodology practical forward, all the transient scenarios registered in a simulator of a 1,000 MWe pressurized water reactor were archived in the transient pattern database. The transient patterns show plant behavior until turbine-generator trip when there is no operator's intervention. Meanwhile, the operating data periodically captured from a plant computer is compared with an individual transient pattern in the database and a highly matched section among the transient patterns enables isolation of the type of transient and prediction of the expected remaining time to trip. The transient pattern database consists of hundreds of variables, so it is difficult to speedily compare patterns and to draw a conclusion in a timely manner. The transient pattern database and the operating data are, therefore, converted into a smaller dimension using the principal component analysis (PCA). This paper describes the process of constructing the transient pattern database, dealing with principal components, and optimizing similarity measures.

Effect of Optical Delay on the Suppression of the Power Transient Excursion in a Combined Gain-Controlled Erbium-Doped Fiber Amplifier

  • Chung, Hee-Sang;Chang, Sun-Hyok;Park, Heuk;Lee, Hyun-Jae;Chu, Moo-Jung
    • ETRI Journal
    • /
    • v.25 no.6
    • /
    • pp.531-534
    • /
    • 2003
  • This report describes the effect of optical delay on the suppression of the power transient excursion in a combined gain-controlled erbium-doped fiber amplifier with an internal optical feedback loop (OFL). A simple homogeneous model showed that the optical delay caused a phase change in the oscillation of the surviving and laser channels, which resulted in a reduction of the overall power transient excursion. In addition to the reduction, a real system with a 1528.7-nm OFL shifted the oscillation upward or downward according to channel removal or addition, whereas another one with a 1560.9-nm OFL did not. This different transient behavior reflected a control-wavelength dependence on optical automatic gain control, where spectral-hole burning dominated over relaxation oscillation for 1528.7 nm, and vice versa for 1560.9 nm.

  • PDF

Transient Response of Magnetic Field Integral Equation Using Laguerre Polynomials as Temporal Expansion Functions (라겐르 함수를 시간영역 전개함수로 이용한 자장 적분방정식의 과도 응답)

  • 정백호;정용식
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.4
    • /
    • pp.185-191
    • /
    • 2003
  • In this Paper, we propose an accurate and stable solution of the transient electromagnetic response from three-dimensional arbitrarily shaped conducting objects by using a time domain magnetic field integral equation. This method does not utilize the conventional marching-on in time (MOT) solution. Instead we solve the time domain integral equation by expressing the transient behavior of the induced current in terms of temporal expansion functions with decaying exponential functions and Laguerre·polynomials. Since these temporal expansion functions converge to zero as time progresses, the transient response of the induced current does not have a late time oscillation and converges to zero unconditionally. To show the validity of the proposed method, we solve a time domain magnetic field integral equation for three closed conducting objects and compare the results of Mie solution and the inverse discrete Fourier transform (IDFT) of the solution obtained in the frequency domain.