• 제목/요약/키워드: Transient

검색결과 8,430건 처리시간 0.035초

반도체 소자의 과도펄스감마선 영향 모델링 및 시뮬레이션 (Modeling and Simulation for Transient Pulse Gamma-ray Effects on Semiconductor Devices)

  • 이남호;이승민
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1611-1614
    • /
    • 2010
  • The explosion of a nuclear weapon radiates a gamma-ray in the form of a transient pulse. If the gamma-ray introduces to semiconductor devices, much Electron-Hole Pairs(EHPs) are generated in depletion region of the devices[7]. as a consequence of that, high photocurrent is created and causes upset, latchup and burnout of semiconductor devices[8]. This phenomenon is known for Transient Radiation Effects on Electronics(TREE), also called dose-rate effects. In this paper 3D structure of inverter and NAND gate device was designed and transient pulse gamma-ray was modeled. So simulation for transient radiation effect on inverter and NAND gate was accomplished and mechanism for upset and latchup was analyzed.

봉상접지극의 과도임피던스 특성 (Transient Impedance Characteristics of Grounding Rods)

  • 김일권;김점식;송재용;길경석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.568-572
    • /
    • 2000
  • This paper describes the experimental results of a transient impedance characteristics of grounding rods to a square pulse and standard lightning impulse current. The test were performed on single grounding rod($\phi$ 10mm, 1m) and triple-grounding rods( $\phi$ 10mm, 1m) of equilateral triangles with 5m spacing. For measurements of transient impedance, a pulse generator which can produce square wave of 30ns rise time and 20U Pulse duration was designed and fabricated. In the experiment, transient impedance of the grounding systems have been investigated from the recorded potential and current waveforms. The results showed that the value of the transient impedance is quite higher than the stationary resistance, and provide useful information for the value of a grounding system considered transient characteristics under a high frequency condition such as lightning stokes and ground-fault.

  • PDF

석유 시추선 전력 계통의 과도 안정도 해석 (Analysis on transient stability for drilling rigs power system)

  • 김윤식;김철호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1119-1124
    • /
    • 2014
  • 본 논문은 석유시추선의 전력 계통 시스템의 비상시 전력 계통 해석에 대하여 기술하였다. 특히 석유시추선의 추진부하와 발전기의 탈락으로 인해 발생하는 전력계통 시스템에 미치는 영향을 검토하였다. 또한 고정 여자방식과 조속기의 제어 변수를 조정하여 임의의 사고 전후 정상상태로의 복귀까지 과도 안정도 해석으로 전력계통에 나타나는 현상을 관찰하였다. 전력계통 설계와 해석 및 과도 현상해석 프로그램인 ETAP(Electrical Transient Analysis Program)을 사용하였으며, 수치해석의 결과를 도출하여 그 특성을 분석하였다.

원전 밀림관 열성층의 3 차원 수치해석 (3-Dimensional Numerical Analysis for Thermal Stratification in Surgeline in Nuclear Power Plant)

  • 김영종;김만원;고은미
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.729-734
    • /
    • 2008
  • A thermal stratification may occur in the horizontal parts of the surge line during operating transients of the pressurizer, which produces relatively high fatigue usage factor. Heat-up transient is the most severe case among the transient conditions. In this study, to study the relationship between the magnitude of thermal stratification and the length of vertical part of the surge line, some parametric fluid-structure interaction (FSI) analyses with different length variables of the vertical part of the surge line were performed for plant heat-up transient condition by using 3-dimensional numerical analysis. The conservativeness of the traditional finite element model for thermal stratification analysis based on the conservative assumption in the surge line was also discussed by comparison of the results of 3-dimensional transient FSI analysis of this study. Stresses calculated with 3-dimensional transient model were considerably reduced comparing with the traditional analysis.

  • PDF

열식 질량 유량계 센서관의 과도 특성에 관한 연구 (Study on the Transient Characteristics of the Sensor Tube of a Thermal Mass Flow Meter)

  • 김동권;한일영;김성진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.308-313
    • /
    • 2003
  • Thermal mass flow meters (TMFMs) are most widely used for measuring mass flow rates in the semiconductor industry. A TMFM should have a short response time in order to measure the time-varying flow rate rapidly and accurately. Therefore it is important to study transient heat transfer phenomena in the sensor tube of a TMFM that is the most critical part in the TMFM. In the present work, a simple numerical model for transient heat transfer phenomena of the sensor tube of a TMFM is presented. Numerical solutions for the tube and fluid temperatures in a transient state are obtained using the proposed model and compared with experimental results to validate the proposed model. Based on numerical solutions, heat transfer mechanism in a transient state in the sensor tube is explained. Finally, a correlation for predicting the response time of a sensor tube is presented. The correlation is verified by experimental results.

  • PDF

전자기 과도현상 해석을 위한 Z 영역에서의 주파수 의존 교류시스템 등가 (Z-Domain Frequency Dependent AC System Equivalent for Electromagnetic Transient Studies)

  • 왕용필;정형환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권6호
    • /
    • pp.296-301
    • /
    • 2002
  • Modern power systems are very complex and to model them completely is impractical for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing Frequency Dependent AC system Equivalent (FDACSE) using Z-domain rational Function Fitting is presented and demonstrated. The FDACSE is generated by Linearized Least Squares Fitting(LSF) of the frequency response of a Z-domain formulation. This 1 & 2 port FDACSE have been applied to the New Zealand South Island AC power system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 1 & 2 port FDACSE developed under different condition (linear load, fault and nonlinear loading). The study results have indicated the robustness and accuracy of 1 & 2 port FDACSE for electromagnetic transient studies.

가전기기에서 발생되는 극저주파 과도자계 예측기법 연구 (Study on Prediction Method for ELF Transient Magnetic Field from Home Appliances)

  • 주문노;양광호;명성호;민석원
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권11호
    • /
    • pp.616-621
    • /
    • 2002
  • With biological effects by ELF (Extremely Low Frequency) magnetic field generated from power system, the transient magnetic field from electric appliances is a major issue presently. Because the transient magnetic field induces higher current than the power frequency field inside living bodies, transient magnetic field exposure has been much focused. In this paper, it is shown that transient magnetic field from electric home appliances can be characterized as magnetic dipole moment. In this method, the dipole moment vector is assumed by allowing an uncertainty of 6dB in the estimated field. A parameter M that represents biological interaction was applied also. The proposed method was applied to 7 types of appliances (hair drier, heater, VDT, etc.) and their equivalent magnetic dipole moment and harmonic components were estimated. As the results, the useful data for quantifying magnetic field distribution around electric appliances were obtained.

A Simple Dynamic Model and Transient Simulation of the Nuclear Power Reactor on Microcomputers

  • Han, Gee-Yang;Park, Cheol
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.605-610
    • /
    • 1997
  • A simple dynamic model is developed for the transient simulation of the nuclear power reactor. The dynamic model includes the normalized neutron kinetics model with reactivity feedback effects and the core thermal-hydraulics model. The main objective of this paper demonstrates the capability of the developed dynamic model to simulate various important variables of interest for a nuclear power reactor transient. Some representative results of transient simulations show the expected trends in all cases, even though no available data for comparison. In this work transient simulations are performed on a microcomputer using the DESIRE/N96T continuous system simulation language which is applicable to nuclear power reactor transient analysis.

  • PDF

345[kV] 100[MVA] STATCOM 과도해석 모델 개발 및 동특성 분석 (The Development of Transient Analysis Model and Performace Analysis of 345[kV] 100[MVA] STATCOM)

  • 윤종수
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.28-34
    • /
    • 2011
  • This paper describes the development of the transient analysis model of 345[kV] 100[MVA] STATCOM and the result of the performance analysis. The Korea power utility company, KEPCO began a commercial operation of a 100[MVA] STATCOM(Static synchronous COMpensator) at 345[kV] Migeum substation in Seoul. In order to operate a new control device like STATCOM to the power system, suitable transient model is needed. Therfore, Korea Electric Power Coporation(KEPCO) developed a transient analysis models using EMTDC/PSCAD. The development of this transient analysis model is based on the actual STATCOM S/W algorithm and H/W specification that was provided by its manufacture. Through this model, the transient/dynamic performance of STATCOM at Migeum substation can be analyzed.

실시간 임베디드 시스템의 결함 허용성 개선을 위한 정적 체크포인팅 방안 (Fault-Tolerance Improvement of Real-Time Embedded System using Static Checkpointing)

  • 유상문
    • 제어로봇시스템학회논문지
    • /
    • 제13권12호
    • /
    • pp.1147-1152
    • /
    • 2007
  • This paper deals with a scheme for fault-tolerance improvement of real-time embedded systems, which engages an equidistant checkpointing technique to tolerate transient errors. Transient errors are caused by transient faults which are the most significant type of fault in reliable computer systems. Transient faults are assumed to occur according to a Poisson process and to be detected in a non-concurrent manner (e.g., checked periodically). The probability of the successful real-time task completion in the presence of transient errors is derived with the consideration of the possible effects of the transient errors. Based on this, a condition under which inserting checkpoints improves the fault-tolerance of the system is introduced and an optimal equidistant checkpointing strategy that achieves the highest fault tolerance is presented.