• 제목/요약/키워드: Transient

검색결과 8,385건 처리시간 0.033초

에너지함수를 이용한 과도불안정 시스템의 안정화 방법 (A New Stabilizing Method for Transiently Unstable Systems by Using Transient Energy Function)

  • 김정우;전영환
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.567-575
    • /
    • 2008
  • Transient security assessment(TSA) is becoming an essential requirement not only for security monitoring but also for stabilizing control of power systems under new electricity environments. It has already been pointed out that fast transient stability study is an important part for monitoring and controlling system security. In this paper, we discuss an energy function method for stabilizing control of transiently unstable systems by introducing generator tripping system to enhance the transient stability of power systems. The stabilization with less tripped power can be obtained by tripping the generators faster than out-of-synchronism relay. Fast transient stability assessment based on the state estimation and direct transient energy function method is an important part of the stabilizing scheme. It is possible to stabilize the transiently unstable system by tripping less generators before the action of out-of-synchronism relay, especially when a group of generator are going to be out-of-synchronism. Moreover, the amount of generator output needed for tripping can be decided by Transient Energy Function(TEF) method. The main contribution of this paper is on the stabilizing scheme which can be running in the Wide Area Control System.

Transient-Performance-Oriented Discrete-Time Design of Resonant Controller for Three-Phase Grid-Connected Converters

  • Song, Zhanfeng;Yu, Yun;Wang, Yaqi;Ma, Xiaohui
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.1000-1010
    • /
    • 2019
  • The use of internal-model-based linear controller, such as resonant controller, is a well-established technique for the current control of grid-connected systems. Attractive properties for resonant controllers include their two-sequence tracking ability, the simple control structure, and the reduced computational burden. However, in the case of continuous-designed resonant controller, the transient performance is inevitably degraded at a low switching frequency. Moreover, available design methods for resonant controller is not able to realize the direct design of transient performances, and the anticipated transient performance is mainly achieved through trial and error. To address these problems, the zero-order-hold (ZOH) characteristic and inherent time delay in digital control systems are considered comprehensively in the design, and a corresponding hold-equivalent discrete model of the grid-connected converter is then established. The relationship between the placement of closed-loop poles and the corresponding transient performance is comprehensively investigated to realize the direct mapping relationship between the control gain and the transient response time. For the benefit of automatic tuning and real-time adaption, analytical expressions for controller gains are derived in detail using the required transient response time and system parameters. Simulation and experimental results demonstrate the validity of the proposed method.

Verification of SARAX code system in the reactor core transient calculation based on the simplified EBR-II benchmark

  • Jia, Xiaoqian;Zheng, Youqi;Du, Xianna;Wang, Yongping;Chen, Jianda
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1813-1824
    • /
    • 2022
  • This paper shows the verification work of SARAX code system in the reactor core transient calculation based on the simplified EBR-II Benchmark. The SARAX code system is an analysis package developed by Xi'an Jiaotong University and aims at the advanced reactor R&D. In this work, a neutron-photon coupled power calculation model and a spatial-dependent reactivity feedback model were introduced. To verify the models used in SARAX, the EBR-II SHRT-45R test was simplified to an ULOF transient with an input flowrate change curve by fitting from reference. With the neutron-photon coupled power calculation model, SARAX gave close results in both power fraction and peak power prediction to the reference results. The location of the hottest assembly from SARAX and reference are the same and the relative power deviation of the hottest assembly is 2.6%. As for transient analysis, compared with experimental results and other calculated results, SARAX presents coincident results both in trend and absolute value. The minimum value of core net reactivity during the transient agreed well with the reported results, which ranged from -0.3$ to -0.35$. The results verify the models in SARAX, which are correct and able to simulate the in-core transient with reliable accuracy.

Assessment of transient vibrations of graphene oxide reinforced plates under pulse loads using finite strip method

  • Mirjavadi, Seyed Sajad;Forsat, Masoud;Barati, Mohammad Reza;Hamouda, A.M.S.
    • Computers and Concrete
    • /
    • 제25권6호
    • /
    • pp.575-585
    • /
    • 2020
  • Based on a refined shear deformation finite strip, transient vibrations of graphene oxide powder (GOP) reinforced plates due to external pulse loads have been investigated. The plate has uniformly and linearly distributed GOPs inside material structure. Applied pulse loads have been selected as sinusoidal, linear and blast types. Such pulse loads result in transient vibrations of the GOP-reinforced plates which are not explored before. Finite strip method (FSM) has been performed for solving the equations of motion and then inverse Laplace transform technique has been employed to derive transient responses due to pulse loading. It is reported in this study that the transient responses of GOP-reinforced plates are dependent on GOP dispersions, GOP volume fraction, type of pulse loading, loading time and load locations.

가변주파수 및 임펄스 전류를 이용한 과도접지임피턴스 분석 (An Analysis Method for the Transient Ground Impedance Using Variable Frequency Current and Lightning Impulse)

  • 조성철;엄주홍;이태형
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.231-234
    • /
    • 2007
  • This paper presents an analysis method of transient ground impedance using the lightning impulse and variable frequency currents. The transient ground impedance strongly depends on the configuration and size of grounding electrodes and the shapes of impulse currents, and the inductance of grounding electrodes has a significant affect on the transient impedance of the grounding system. There are some differences between the effective impulse ground impedance which was introduced some papers and the transient ground impedance. The transient ground impedance measured from the peak value of impulse voltage and the peak value of impulse current is more reliable than the effective impulse ground impedance.

  • PDF

객체지향기반 과도 안정도 해석 (Transient Stability Analysis Based on OOP)

  • 박지호
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.354-362
    • /
    • 2008
  • This paper presents the new method of power system transient stability simulation, which combines the desirable features of both the time domain technique based on OOP(Object-oriented Programming) and the direct method of transient stability analysis using detailed generator model. OOP is an alternative to overcome the problems associated with the development, maintenance and update of large software by electrical utilities. Several papers have already evaluated this approach for power system applications in areas such as load flow, security assessment and graphical interface. This paper applied the object-oriented approach to the problem of power system dynamics simulation. The modeling method is that each block of dynamic system block diagram is implemented as an object and connected each other. In the transient energy method, the detailed synchronous generator model is so-called two-axis model. For the excitation model, IEEE type1 model is used. The developed mothed was successfully applied to New England Test System.

Thyristor 직류 Chopper방식으로 구동되는 직류타여자식 전동기의 과도특성해석법 (Transient Characteristics of Separately Excited d-c Motor Driven by Thyristor d-c Chopper)

  • 천희영
    • 전기의세계
    • /
    • 제21권2호
    • /
    • pp.9-19
    • /
    • 1972
  • The transient characteristics of separately excited d-c motor driven by thyristor d-c chopper is studied in this paper. The armature controlled system is applied. As a result of theoretrical analysis the following conculsions were drawn: (1) For the transient analysis, it is recognized that the state transition analysis is a more general method and powerful tool than the state equation method or signal flow graph method, although it includes iterative matrix calculations. And the system is dealt with a finite width sampled-data system in the state transition analysis. (2) The transient characteristics of the motor angular velocity and its torque to the sampling duration variation are compared with those due to the amplitude variation of d-c chopper voltage as follows. The attenuation rate of the transient characteristics is equal in both cases, but the initial value of the transient characteristics in former case is greater than in latter case. (3) The roots of characteristics equation of the system lie inside the unit circle of the Z-plane. Therefor the system is stable. Further it is found that as the sampling duration is decreased the relative stability is lessened.

  • PDF

미소유동 채널에서 중첩된 전기이중층 구조의 과도 형성과정 (Transient Evolution of Overlapped EDL Fields in a Microfluidic Channel)

  • 곽호상
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1528-1533
    • /
    • 2004
  • A numerical investigation is made of transient evolutionary prcocess of electroosmotic flow in a two-dimensional microchannel connected to a reservoir. The channel height is very small so that two electric double layers forming on the charged surfaces are overlapped. Transient transports of ions in the electrolyte solution are computed by integrating the Nernst-Planck equation together with the Poisson equation for electric potential. The numerical results illustrate that there are two distinct transient phases. The physical mechanisms and relevant time scales for the transient evolution are described.

  • PDF

Measurement of Transient Electric Field Emission from a 245 kV Gas Insulated Substation Model during Switching

  • Rao, M. Mohana;Thomas, M. Joy;Singh, B.P.
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.306-311
    • /
    • 2007
  • The transient fields generated during switching operations in a Gas Insulated Substation (GIS) are associated with high frequency components in the order of few tens of MHz. These transient fields leak into the external environment of the gas-insulated equipment and can interfere with the nearby electronics. Measurements of the transient fields are thus required to characterise the interference caused by switching phenomena in such substations. In view of the above, E-field emission measurement during a switching operation has been carried out for a 245 kV GIS model, using a resonant dipole antenna and D-dot sensor. The characteristics of the E-fields i.e., frequency spectra and their levels have been analysed and are reported in the paper. Suitability of the measurements has been confirmed by comparing frequency spectra of the measured and computed transient fields.

반도체 소자의 과도펄스감마선 영향 모델링 및 시뮬레이션 (Modeling and Simulation for Transient Pulse Gamma-ray Effects on Semiconductor Devices)

  • 이남호;이승민
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1611-1614
    • /
    • 2010
  • The explosion of a nuclear weapon radiates a gamma-ray in the form of a transient pulse. If the gamma-ray introduces to semiconductor devices, much Electron-Hole Pairs(EHPs) are generated in depletion region of the devices[7]. as a consequence of that, high photocurrent is created and causes upset, latchup and burnout of semiconductor devices[8]. This phenomenon is known for Transient Radiation Effects on Electronics(TREE), also called dose-rate effects. In this paper 3D structure of inverter and NAND gate device was designed and transient pulse gamma-ray was modeled. So simulation for transient radiation effect on inverter and NAND gate was accomplished and mechanism for upset and latchup was analyzed.