• Title/Summary/Keyword: Transformer-less

Search Result 188, Processing Time 0.027 seconds

Chemical Treatment of the PCBs-laden Transformer Insulation Oil (PCBs 함유 변압기 절연유의 화학적처리)

  • Ryoo, Keon-Sang;Choi, Jong-Ha;Choi, Jin-Whan
    • Journal of Environmental Science International
    • /
    • v.20 no.11
    • /
    • pp.1499-1507
    • /
    • 2011
  • Practical disposal of transformer insulation oil laden with PCBs (polychlorinated biphenyls) by a chemical treatment has been studied in field work. The transformer insulation oil containing PCBs was treated by the required amounts of PEG (polyethylene glycol) and KOH, along with different reaction conditions such as temperatures and times. The reaction of PEG with PCBs under basic condition produces arylpolyglycols, the products of nucleophilic aromatic substitution. Removal efficiencies of PCBs in insulation oil before and after chemical treatment were examined. The removal efficiency of PCBs was very low at lower temperatures of 25 and $50^{\circ}C$. Under the reaction condition of PEG 600/KOH/$100^{\circ}C$/2hr, removal efficiency of PCBs was approximately 70%, showing completely removal of PCBs containing 7~9 chlorines on biphenyl frame which appear later than PCB IUPAC Number 183 (2,2',3,4,4',5',6-heptaCB) in retention time of GC/ECD. However, when increasing the reaction temperature and time to $150^{\circ}C$ and 4 hours, removal efficiency of PCBs reached 99.99% without any formation of PCDDS/PCDFs during the process. Such reaction conditions were verified by several official analytical institutions. In studying the reaction of PEG with PCBs, it confirmed that the process of chemical treatment led to less chlorinated PCBs through a stepwise process with the successive elimination of chlorines.

DC Rail Side Series Switch and Parallel Capacitor Snubber-Assisted Edge Resonant Soft-Switching PWM DC-DC Converter with High-Frequency Transformer Link

  • Morimoto, Keiki;Fathy, Khairy;Ogiwara, Hiroyuki;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.181-190
    • /
    • 2007
  • This paper presents a novel circuit topology of a DC bus line series switch and parallel snubbing capacitor-assisted soft-switching PWM full-bridge inverter type DC-DC power converter with a high frequency planar transformer link, which is newly developed for high performance arc welding machines in industry. The proposed DC-DC power converter circuit is based upon a voltage source-fed H type full-bridge soft-switching PWM inverter with a high frequency transformer. This DC-DC power converter has a single power semiconductor switching device in series with an input DC low side rail and loss less snubbing capacitor in parallel with the inverter bridge legs. All the active power switches in the full-bridge arms and DC bus line can achieve ZCS turn-on and ZVS turn-off transition commutation. Consequently, the total switching power losses occurred at turn-off switching transition of these power semiconductor devices; IGBTs can be reduced even in higher switching frequency bands ranging from 20 kHz to 100 kHz. The switching frequency of this DC-DC power converter using IGBT power modules can be realized at 60 kHz. It is proved experimentally by power loss analysis that the more the switching frequency increases, the more the proposed DC-DC power converter can achieve a higher control response performance and size miniaturization. The practical and inherent effectiveness of the new DC-DC converter topology proposed here is actually confirmed for low voltage and large current DC-DC power supplies (32V, 300A) for TIG arc welding applications in industry.

Contact-less Power Supply Using Series-Parallel Rasonant Converter ($\cdot$병렬 공진형컨버터를 이용한 비접촉전원)

  • Kim E. S.;Goo D. H.;Kim J. M.;Kang D. H.;Shin B. C.;Kong Y. S.;Yang S. C.
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.103-107
    • /
    • 2002
  • A contact-less power supply system (CPS) allows electrical energy to supply to mobile consumers without any electrical or mechanical contact. CPS works in the same principle as a transformer, with the track litz cable forming the primary circuit and the pickup as the secondary. The track power supply generates the high frequency alternating current in the track cable. The captured AC magnetic field generated by the track conductors produces electrical energy in the pickup coil and the pickup rectifier converts the high frequency AC power to DC while regulating the power to the load. This paper presents the theoretical analysis, simulation and experiment리 results of the series-parallel resonant converter working as contact-less power supply system.

  • PDF

A Study on Insulation Design of HTS Transformer (초전도 변압기의 절연 설계에 관한 연구)

  • 정종만;백승명;김영석;곽동순;김상현
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.232-235
    • /
    • 2003
  • To realize the development of HTS power apparatus, various breakdown test of L$N_2$ should be carried out and the mechanism should be understood more. Moreover the dielectric design technology that the basic dielectric experimental data applied to the HTS power system should be developed. In this paper, the electric fields for the insulation design were calculated for example with the analysis of Weibull distribution. And V-t characteristics of L$N_2$ were discussed. Around the breakdown voltage the n values were less than 1.

  • PDF

Analytical Examination of KERI Synthetic Short-circuit Current Making Test Circuit (KERI 합성투입시험회로의 해석적 고찰)

  • Lee, Yong-Han
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.455-457
    • /
    • 2003
  • In the present IEC 60427(2000), reduced applied voltage can be used for synthetic short-circuit making current tests if the maximum pre-arcing time of the test circuit breaker is less than $1/{\omega}$. But in the near future IEC, only the making tests with full test voltage shall be allowed. To meet this trend, KERI is preparing synthetic making test facilities using step-up transformer, ITMC and plasma making switch. This paper presents analytical characteristics of KERI's synthetic short-circuit making test circuits. The results of this paper can be useful for effective and adequate tests.

  • PDF

A Study of Maglev Train Inverter and Converter Noise (자기부상열차용 인버터 및 컨버터 소음에 관한 연구)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kang, Hyun-Joo;Kim, Bong-Ki;Kim, Sang-Rul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.346-351
    • /
    • 2002
  • Noise of the VVVF inverter and DC/DC converter, which are the most dominant noise sources of maglev train at low speed, is studied, The coils inside inverter and converter are excited by electro-magnetic forces, which results in core vibration and generations of the noise. It is found that the spectra of the noise show many harmonics, where there exist several different fundamental frequencies. Some noise reducing techniques are known for the transformer noise such as changing stiffness and using different core materials, which make less electrostatic responses, and consequently less noise. In this study, it is shown that the most effective and feasible noise reducing method is to increase the switching frequencies of the inverter and converter, where peaks in higher frequency are significantly reduced.

  • PDF

Contactless Power Supply for DC Power Service in Hybrid Home Generation System (직류수용가 서비스를 위한 무접점 전원장치)

  • Kang, J.W.;Song, H.K.;Kim, J.H.;Kim, E.S.;Kim, Y.H.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.104-107
    • /
    • 2007
  • Among the alternative energy sources, the solar energy is recognized as an important energy source and its application is increasing. Especially in future, the hybrid solar energy generation system with battery will be widely used as an independent distributed power generation system. In this paper, a solar power hybrid home generation system using a contact-less power supply (CPS) that can transfer an electric power without any mechanical contact by using magnetic coupling instead of the power transfer by directly supplying the DC power to the home electric system is proposed. The proposed system consists of a ZVS boost converter, a half bridge LLC resonant converter and contact-less transformer.

  • PDF

A Study on Efficient Natural Language Processing Method based on Transformer (트랜스포머 기반 효율적인 자연어 처리 방안 연구)

  • Seung-Cheol Lim;Sung-Gu Youn
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.4
    • /
    • pp.115-119
    • /
    • 2023
  • The natural language processing models used in current artificial intelligence are huge, causing various difficulties in processing and analyzing data in real time. In order to solve these difficulties, we proposed a method to improve the efficiency of processing by using less memory and checked the performance of the proposed model. The technique applied in this paper to evaluate the performance of the proposed model is to divide the large corpus by adjusting the number of attention heads and embedding size of the BERT[1] model to be small, and the results are calculated by averaging the output values of each forward. In this process, a random offset was assigned to the sentences at every epoch to provide diversity in the input data. The model was then fine-tuned for classification. We found that the split processing model was about 12% less accurate than the unsplit model, but the number of parameters in the model was reduced by 56%.

A Study on the Effects of I&C Systems by EMI Generating from Corona Discharge at Transformer Area (변압기 지역 코로나 전자파 간섭에 의한 계측제어설비 영향에 관한 연구)

  • Min, Moon-Gi;Lee, Jae-Ki;Park, Jin-Yeub;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.266-271
    • /
    • 2014
  • The Electromagnetic Interference(EMI) generating from corona discharge of transformer area can interference the digital Instrument and Control(I&C) systems located nearby transformers. When the potential gradient of the electric field around the conductor is high enough to form a conductive region but not high enough to cause electrical breakdown to nearby objects, the EMI of corona discharge emits with the conducted and radiated noise and it interferences the signals of the I&C systems. Since digital I&C systems have an efficiency and competitive price, the analog I&C systems have been upgraded and displaced with the digital I&C systems but which have less EMI Immunity. There was no assessment to I&C systems by EMI generating corona discharge nearby transformers. When the safety-related I&C systems are installed in plants, the verification of equipment EMI should be done not in site-specific test but in test facilities. There are the need to do the site-specific EMI evaluation of corona discharge nearby transformers. This paper assesses the margin between plant emission limits and the highest composite plant emission of corona. When the non safety-related I&C systems are placed in transformer area, it suggests the appropriate radiated susceptibility level to EMI of corona discharge.

Design of a High-Voltage Piezoelectric Converter for Airbag Ignition Modules

  • Xiao, Hongbing;Du, Yu;Bai, Chunyu;Guo, Zerong;Yen, Kang K.
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.183-193
    • /
    • 2014
  • Due to the requirements for high reliability and accuracy, safety issues for airbag ignition systems need to be studied. In this paper, a high-voltage piezoelectric converter is designed to improve these requirements in airbag ignition systems. The proposed converter includes an inverter drive circuit, a Rosen piezoelectric transformer (PZT), an output circuit and a feedback control circuit. The key components of the high-voltage piezoelectric transformer are analyzed in detail. In addition, the proposed converter system is simulated and implemented for testing. The experimental results show that when the power supply is turned on, the charging time is less than 800ms. Furthermore, the output voltage of this converter can be kept between 2.9kV and 3.1kV, under high-efficiency constant current charging mode and zero-voltage switching conditions.