• Title/Summary/Keyword: Transformer oil

Search Result 400, Processing Time 0.027 seconds

Estimation on the application of Reference Materials for PCBs Proficiency Testing from the transformer oil (폐절연유를 이용한 숙련도 평가용 PCBs 표준물질의 적용성 평가)

  • Kim, Woo-Il;Kwon, Myung-Hee;Jeon, Tae-Wan;Kim, Dong-Hoon;Chun, Jin-Won;Sim, Ki-Tae;Yeon, Jin-Mo
    • Analytical Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.247-254
    • /
    • 2010
  • This study was carried out to produce Reference Materials (RMs) for Proficiency Testing (PT) of PCBs in waste analytical laboratories. Two RMs were prepared from used transformer oil samples and PCB free transformer oil by spiking PCBs standard solutions. The spiked PCB RMs were homogenized by mixing and settling up to 90 days. Homogenized concentration of PCBs with Arochlor 1254 (6 ppm), 1254:1260 (1:1) (5 ppm) were observed in 60 days stationary phase but Arochlor 1260 (3.5 mg/L) were observed in 90 days stationary phase. One-way ANOVA test were carried out and showed that the RMs were suitably homogenized, which can be used for proficiency testing. The Relative Standard Deviations (RSDs) of analytical results were 3.51~5.01% for the PCBs RMs in 10 replicates. The expanded uncertainty of PCBs analytical procedure were 0.26~0.49.

Detoxification of PCBs Containing Transformer Oil by Catalytic Hydrodechlorination in Supercritical Fluids (초임계유체 내 수첨탈염소반응에 의한 PCBs가 함유된 절연유의 무해화 연구)

  • Choi, Hye-Min;Kim, Jae-Hoon;Kim, Jae-Duck;Kang, Jeong-Won
    • Clean Technology
    • /
    • v.15 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Catalytic hydrodechlorination of PCBs (polychlorinated biphenyls) included in the transformer oil was carried out to detoxify PCBs and to recycle the treated oil. Catalysts such as 0.98 wt% Pt and 0.79 wt% Pd on ${\gamma}$-alumina (${\gamma}-Al_2O_3$) support, 12.8 wt% Ni on ${\gamma}-Al_2O_3$, and 57.6 wt% Ni on silica-alumina ($SiO_2-Al_2O_3$) support were used for the catalytic hydrodechlorination. Various supercritical fluids such as carbon dioxide, propane and isobutane were used as reaction media. The effects of reaction temperature, reaction time, catalysts, and supercritical fluids on the catalytic hydrodechlorination were examined in detail. The detoxification degree increased in the order of Ni > Pd > Pt. This is possibly due to higher metal loading and larger metal size of the Ni catalyst. Below $175^{\circ}C,\;scCO_2$ was found as the most effective reaction media for the catalytic hydrodechlorination of PCBs included in the transformer oil.

The Evaluation of Thermal Aging for Insulation Paper with Mineral and Vegetable Oil (광유 및 식물성 절연유에서 절연지의 열적 열화 특성 평가)

  • Lee, Byung-Sung;Song, Il-Keun;Kim, Dong-Myung;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1558-1560
    • /
    • 2004
  • Liquid-immersed pole transformers have utilized an insulation system consisting of natural cellulose-based materials and mineral oil for many years. If the transformers are installed with the abruptly changing load over limitation, its insulation materials are apt to unexpected aging with high temperature. Therefore we have been conscious of developing a transformer that is more thermally stable then conventional types. To measure temperature distribution in the winding of conventional and newly designed transformers, temperature sensors were installed fordirect reading of oil and conductor temperatures at transformers. And we conducted accelerating aging test for these transformers. The measuring data had made use of the design to hybrid insulation system. Also we could find the possibility of this insulation system to apply in pole mounted transformers.

  • PDF

Measurement of Electromagnetic Wave Generated by Partial Discharges in an Insulation Oil (유중 부분방전에 의한 방사전자파의 측정)

  • Park, Dae-Won;Lee, Jung-Yoon;Cho, Hyang-Eun;Kim, Min-Su;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1453-1458
    • /
    • 2011
  • This paper dealt with the measurement and analysis of electromagnetic waves generated by partial discharges in insulation oil to develop insulation diagnostic techniques for power transformer. Two types of narrow-band monopole antennas with the resonant frequency of 500 MHz and 1 GHz were designed and fabricated. We simulated defects which consist of a needle electrode with curvature radius of 10 ${\mu}m$ and a plane electrode with diameter of 60 mm in insulation oil. From the experiment, the maximum output voltage of the fabricated antennas was measured; 620 $mV_{max}$ for 500 MHz resonant frequency and 920 $mV_{max}$ for 1 GHz resonant frequency.

  • PDF

Electrical Breakdown Properties of Oil-paper Insulation under Pulsating Voltage Influenced by Temperature

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1735-1743
    • /
    • 2016
  • Insulation of valve-side windings in converter transformer withstands pulsating voltages, which will produce more serious insulation problems. In this paper, the electric breakdown experiments of oil-paper insulation specimens were executed at pulsating voltages and different temperatures. Experiment and analysis results showed that the breakdown voltage decreased with increasing temperature under pulsating voltage. The influence of temperature proves to be more significant once the temperature exceeds a limitation threshold. A fitting formula between breakdown voltage and the temperature was reported. Finally, in order to clearly understand the breakdown properties under pulsating voltage, the electric field distribution and space charge behavior under pulsating voltage at different temperature were discussed.

Development of Phase Sensitive Detector for Diagnosis of Distribution Transformers (배전용 변압기의 진단을 위한 위상 검출 장치의 개발)

  • Kim, Young-Chun;Choi, Do-Hyuk;Yoon, Yong-Han;Min, Kyeoung-Rae;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.547-549
    • /
    • 2000
  • This paper develops phase sensitive detector for diagnosis of distribution transformers. And to detect the $tan{\delta}$ more effectively, this paper used phase sensitive detector. The sensor in oil which could be placed inside of the distribution transformer can measures the $tan{\delta}$ in oil. This could be the important factor and information, and it could be used for the basic information for a precise diagnosis. Establishment of the proposed system helps to build the confidence in monitoring of the oil-filled transformers.

  • PDF

The optical measurement and wavelet analysis about ultrasonic signals by discharge in oil (유중방전 초음파 신호의 광학적 측정 및 wavelet 분석)

  • Lee, S.H.;Lee, H.C.;Jee, S.W.;Kim, Ch.N.;Song, H.J.;Lee, K.S.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.298-303
    • /
    • 2004
  • It is well known that a discharge in oil is the source of various physical phenomena. Ultrasonic-wave detection is a useful method to the diagnosis of the transformer-insulation condition. Conventionally, ultrasonic waves are detected by Piezo-electric transducer, and we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test arrangement is based rut the needle-plane electrode system in oil and applied AC high voltage Ultrasonic waves were detected and showed signal- analysis results with wavelet transform.

  • PDF

Development of Capacitive Sensor for the Diagnosis of Electrical Insulating Oil (전기절연유의 열화진단을 위한 정전용량 센서개발)

  • Choi, N.H.;Kim, H.J.;Kim, J.H.;Kim, H.S.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1609-1611
    • /
    • 2003
  • This paper presents the results on the development of capacitive sensor for the diagnosis of electrical insulating oil, widely used for power transformer. To survey the dielectric properties of the new and used mineral insulating oil, we utilized the highly precise measuring system of KRISS. And the results were used to determine the design factors of the sensor. To evaluate the operational and the hysteresis characteristics of the sensor, we constructed a test chamber, including dielectric property measuring system. Through the results we could confirm the superior characteristics of the newly developed sensor.

  • PDF

Contamination level and congener profiles of PCBs, Co-PCBs and PCDD/DFs in transformer insulation oil samples (변압기 절연유 중 PCBs, Co-PCBs 및 PCDD/PCDFs 오염수준 및 이성체 분포)

  • Kim, Kyoung-Soo;Kim, Jong-Guk;Shin, Sun-Kyoung;Kim, Kyoung-Sim;Song, Byung-Joo
    • Analytical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.263-271
    • /
    • 2006
  • The levels of total PCBs, Co-PCBs and PCDD/Fs in the transformer insulation oil samples obtained using GC/ECD and HRGC/HRMS were ranged from N.D. to 77.3 ppm, from 0.0863 to 2.49 ppm and from N.D. to 0.00241 ppm, respectively. In terms of WHO-TEQ values, Co-PCBs and PCDD/Fs were ranged from 23.3 to 600 pgTEQ/g and from N.D. to 128 pgTEQ/g, respectively (${\Sigma}Co$-PCBs+PCDD/Fs concentration was calculated 24.4~728 pgTEQ/g). Although, the contribution of PCDD/Fs was below 12% in total TEQ concentration, it is suggested contamination of PCDD/Fs in transformer insulation oils. Among 10 samples, 4 samples showed higher concentration than 2 ppm (specific waste criterion of Korea) and Aroclor 1242, 1248, 1254 and 1260 was detected in samples as a single or mixture of Aroclor. It was shown reliable relationship between concentration of Co-PCBs and those of PCDD/Fs (p<0.003), however, was not shown between production year of transformer and concentration of PCBs. The distribution pattern of Co-PCB congeners showed that the ratios of mono-ortho substituted congeners were higher than non-ortho substituted congeners. Among that, PCB-118 congener was predominant. In addition, the OCDD congener was predominated in PCDD/Fs congeners as above 53%. Moreover, the congener pattern of Co-PCBs was similar to that of Aroclor as well as ambient air, which suggested that PCBs volatilization from transformer insulation oil affected the pattern of Co-PCBs in ambient air.

A Study on the Detection of Acoustic Signal Produced by Partial Discharges in Insulation Oil and its Positioning (부분방전에 의한 음향신호의 검출과 위치추정에 관한 연구)

  • Kil, Gyung-Suk;Park, Dae-Won;Kim, Il-Kwon;Choi, Su-Yeon;Park, Chan-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.907-911
    • /
    • 2007
  • This paper dealt with the frequency spectrum analysis of acoustic signal produced by partial discharge (PD) in insulation oil and the positioning of PD occurrence to apply in diagnosis of oil insulated transformers. Three types of electrode system ; the needle-plane, the plane-plane, and the wire-wire structure were assembled to simulate partial discharges in oil insulated transformers. A low-noise amplifier and a decoupling circuit were designed to detect acoustic signal with high sensitivity The frequency spectrum of the acoustic signal were 50 kHz ${\sim}$ 260 kHz in the needle-plane, 50 kHz ${\sim}$ 250 kHz in the plane-plane, and 45 kHz${\sim}$195 kHz in the wire-wire electrode system. Their peak frequencies were 145 kHz, 130 kHz and 114 kHz, respectively The position of PD occurrence was calculated by the time difference of arrival (TOA) using three acoustic emission (AE) sensors, and we could find the position within the error of 1 % in the experimental apparatus.