• 제목/요약/키워드: Transformer oil

검색결과 400건 처리시간 0.028초

$SF_6$ 가스절연변압기에서 권선의 섹션에 대한 절연내력 연구 (A Study on the Dielectric Strength in Section of Winding in SF6 Gas Transformer)

  • 허우행;하영식;홍정표;김규탁
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권3호
    • /
    • pp.152-158
    • /
    • 2000
  • This paper deal with the experimental discussion about the impulse and AC dielectric strength of SF6 gas insulated transformer. Test sample is measured the dielectric breakdown voltage about modeling of the first and second section which is the weakest for surge voltage. The AC breakdown voltage is appeared 1.4 times than impulse breakdown voltage, so we can estimate that the impulse breakdown voltage is severe to AC breakdown voltage, and when the impulse is applied, in case of lmm tapping with Nomex paper, the characteristics of dielectric breakdown voltage is same to that in oil immersed transformer when SF6 gas pressure is 2.2kg/$cm^2$G.

  • PDF

절연유중 부분방전 검출을 위한 안테나의 최적 설계 (Optimal Design of an Antenna for the Detection of Partial Discharges in Insulation Oil)

  • 이정윤;조향은;박대원;길경석;오재근
    • 한국전기전자재료학회논문지
    • /
    • 제26권4호
    • /
    • pp.309-314
    • /
    • 2013
  • This paper dealt with the radiated electromagnetic wave detection of partial discharge (PD) in oil for insulation diagnostics of oil-immersed transformers. Three types of electrode system were fabricated to simulate the insulation defects that could occur in oil-immersed transformers. Frequency components of radiated electromagnetic wave in oil was measured by broadband bi-conical antennas of 300 MHz~2 GHz and a spectrum analyzer of 9 kHz~3 GHz. Frequency component of electromagnetic waves from PD in oil were highly distributed at 500 MHz. From the result, a narrow-band monopole antenna with the center frequency of 500 MHz was fabricated. We could detect PD signal in insulation oil without an influence of external noise by a measurement system which consists of the prototype monopole antenna, a LNA (Low Noise Amplifier), an oscilloscope and a spectrum analyzer.

주상변압기의 절연매질인 광유의 절연파괴특성에서 분해생성물의 영향 (Effect of Decomposition Product on the Insulation Characteristics of Mineral Oil as Insulation Medium of Distribution Transformer)

  • 임동영;박숭규;박철호;김기채;이광식;최은혁
    • 조명전기설비학회논문지
    • /
    • 제28권6호
    • /
    • pp.52-59
    • /
    • 2014
  • This paper deals with the effect of decomposition products which occur in breakdown of mineral oil, on the insulation characteristics of its oil. Breakdown tests in the oil were conducted by the proposed experimental methods under a quasi-uniform field and AC HV (60Hz). The breakdown voltage in the oil shows characteristics of dispersion from successive breakdowns and, it is found that there are three patterns of the decomposition products behavior at the process of breakdown progress in the oil. Finally, the breakdown voltage dispersion in the oil can be described in detail based on the behavior patterns of the decomposition products and its diffusion time.

변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구 (A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer)

  • 김도현;조남욱;윤충호;박필용;박근성
    • 한국화재소방학회논문지
    • /
    • 제31권5호
    • /
    • pp.53-62
    • /
    • 2017
  • 경제 및 산업의 원천 에너지원인 전력은 생산과 소비의 지역적 상이함으로 장거리 수송을 필수로 하며, 다중환상망(Multi-loop) 형식의 송배전계통으로 전력을 공급한다. 실질적 사용에 앞서, 변전소내 변압기를 통해 변전과정을 거쳐 각 사용처의 특성을 고려하여 전력공급이 이루어지고 있으며 변압기는 본체, 권선, 절연유, 부싱등의 구조로 결합되어 있다. 변전소에서 발생하는 변압기화재는 가구와 상업시설등에 전기공급을 중단시키고 각종 안전사고를 발생시키는 1차 손실뿐만 아니라 2차적으로 경제 손실을 야기한다. 화재의 원인은 부싱 하부파손에 따른 절연유 유출과 약 1초 이내 발화점에 도달하는 절연유에 의한 화재의 연쇄반응으로 파악된다. 화재피해의 최소화를 위해 연기감지기, 자동소화설비 등이 구축되어있으나 감지기의 동작 및 소화가스 방출지연 등으로 화재진화를 위한 골든타임 확보의 부재가 문제되고 있다. 이에 본 연구는 초기 화재진화에 따른 골든타임 확보의 중요성에 따라 화재확산을 방지하고 절연유 누출을 차단하는 능동적 메커니즘의 필요에 따라 수행되었다. 따라서 화염에 의해 팽창하는 고온형상 유지물질과 기계적 화염차단장치를 적용한 부싱방화구조체를 개발하였다. 실제 부싱 및 프렌지규격을 적용하여 제작된 변압기모형에 부싱방화구조체를 설치하여 실규모 화재실험을 수행하였다. 초기화염으로부터 3초내에 정확한 위치와 높이에 부싱방화구조체가 작동함을 확인하였으며 이는 실제 변압기화재 시 화염 확대를 효과적으로 차단할 수 있을 것으로 사료된다.

변압기 절연유중 수소 가스의 검지 시스템 설계 (Developement of Gas Detector Dissolved In Transfomer Oil)

  • 황규현;서호준;이동희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1842-1844
    • /
    • 2004
  • In oil-filled equipment such as transformers, partial discharge or local overheating will make insulating material(oil, kraft paper, proclain and wood) be stressed and generate many sort of gases(CO, $CO_2,\;H_2,\;C_2H_4$) which are dissolved in transformer oil. The ratio of this gas can make diagnostic tecchniques of the lifetime of transfomer so, it is important to monitoring $H_2$ gas continuously. This paper developes a system of detecting about $H_2$ gas by using $H_2$ gas sensor, and we describe operation and performance of this system.

  • PDF

회전원통을 이용한 유입 변압기의 유동대전에 관한 연구 (A Study on the Static Electrification for Oil-Immersed Power Transformers Using a Spinning Cylinder)

  • 정용기;권동진;손철근;곽희로
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1993년도 추계학술발표회논문집
    • /
    • pp.83-88
    • /
    • 1993
  • This paper persents the measurement method using a spinning cylinder system for stream-ing electrification of transformer oil. The spinning cylinder system has a simple mechan-ical construction, and requires less oil com-pared to the other methods. Alse, the effects of various admixtures on the static electri-fication and properties of tranformer oil can be easily investigated. Experiments showed that addition of the BTA reduced the streaming electrification and the polarity of static electrification wasconver-ted to negative at 50 ∼ 70[ppm] of BTA

  • PDF

AC 브리지 회로에 의한 주상 변압기의 감시 기법 (A Monitoring Technique of Pole Transformers using AC Bridge Circuit)

  • 윤용한;민경래;최도혁;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.544-546
    • /
    • 2000
  • This paper presents a monitoring technique of pole transformers using AC bridge circuit. And to detect the capacitance in oil more effectively, this paper used AC bridge circuit. The sensor in oil which could be placed inside of the distribution transformer can measures the changes of capacitance in oil. And with the sensing of the upper part's capacitance, it is possible to determine the changes of the oil height. Establishment of the proposed system helps to build the confidence in monitoring of the pole transformers.

  • PDF

변압기절연유 누설전류와 변압기열화의 상관성 분석 (A study of oil transformer diagnosis on TOID system)

  • 강창원;최길수;홍성준;전영갑;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1894-1896
    • /
    • 2000
  • A Study on TOID system which can measure a degree of diagnosis oil Tr. TOID system uses porous ceramic sensor and accept a DC 2000V, this method is to accumulate carbon element generated from the both electrodes from the ingredients the sensor when being vaporized the oil. The main substance of our research were comparison between vaporizing detection result of the oil, gas analysis, withstand voltage, test of acid value, and to define a new technology of measurement.

  • PDF

변압기내 부분방전의 종류에 따른 초음파 신호 특성 (Characteristics of Ultrasonic Signals by Partial Discharge Types)

  • 박현수;박재도;정용기;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1897-1899
    • /
    • 2000
  • This paper describes the frequency characteristics and the number of pulse of ultrasonic signals due to partial discharge occurred at each electrode. The defects which could occur in a transformer were simulated by using needle-plane electrode, IEC(b) electrode and void electrode. As a result, the dominant frequency of ultrasonic signals generated by corona in oil and partial discharge in void was hardly changed regardless with the applied voltage, but in case of surface discharge in oil, its dominant frequency moved to low frequency with the applied voltage. The increasing rate of pulse number per second was high in order of the surface discharge in oil, the partial discharge in void, the corona in oil.

  • PDF

Study on Decomposition Gas Characteristics and Condition Diagnosis for Gas-Insulated Transformer by Chemical Analysis

  • Kim, Ah-Reum;Kwak, Byeong Sub;Jun, Tae-Hyun;Park, Hyun-Joo
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.447-454
    • /
    • 2020
  • Since SF6 gas was discovered in the early 1900s, it has been widely used as an insulation material for electrical equipment. While various indicators have been developed to diagnose oil-immersed transformers, there are still insufficient indicators for the diagnosis of gas-insulated transformers. When necessary, chemical diagnostic methods can be used for gas-insulated transformers. However, the field suitability and accuracy of those methods for transformer diagnosis have not been verified. In addition, since various types of decomposition gases are generated therein, it is also necessary to establish appropriate analysis methods to cover the variety of gases. In this study, a gas-insulated transformer was diagnosed through the analysis of decomposition gases. Reliability assessments of both simple analysis methods suitable for on-site tests and precise analysis methods for laboratory level tests were performed. Using these methods, a gas analysis was performed for the internal decomposition gases of a 154 kV transformer in operation. In addition, simulated discharge and thermal fault experiments were demonstrated. Each major decomposition gas generation characteristics was identified. The results showed that an approximate diagnosis of the inside of a gas-insulated transformer is possible by analyzing SO2, SOF2, and CO using simple analysis methods on-site. In addition, since there are differences in the types of decomposition gas generation patterns with various solid materials of the internal transformer, a detailed examination should be performed by using precise analysis methods in the laboratory.