• 제목/요약/키워드: Transformer Substation

검색결과 159건 처리시간 0.028초

The Analysis Results of Lightning Overvoltages by EMTP for Lightning Protection Design of 500kV Substations

  • Ju Hyung-Jun;Lee Heung-Ho
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권4호
    • /
    • pp.366-370
    • /
    • 2005
  • To meet increasing power demand, 500 kV power systems are under consideration in the regions of some Middle Asian countries. As the power system voltage becomes higher, the cost for the power system insulation increases significantly. 500 kV transmission systems will become the basis of a region's power system and they require much higher system reliability. Consequently, by the methods of limiting overvoltages effectively, a reasonable insulation design and coordination must be accomplished. In particular, the Substations must be constructed to be of outdoor type. In order to determine the various factors for the insulation design, the EMTP (Electro-magnetic transient program) is used for the magnification of transient phenomena of the 500 kV systems in the planned network. In this paper, we will explain the calculation results of lightning overvoltages by the EMTP for lightning protection design for the 500 kV substations. To obtain reliable results, the multi-story tower model and EMTP/TACS model are introduced for the simulation of dynamic arc characteristics.

Gas 색연(絶綠) 개폐장치(開閉裝置)의 철공진(鐵共振) 제어대책(制御對策)에 관한 연구(硏究) (A Study on the Elimination of Temporary overvoltage Due to Ferroresonance at Gas Insulated Switchgear)

  • 김승규;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.216-221
    • /
    • 2000
  • This paper describes the analysis results on the PT ferroresonance at 154 kV GIS (gas Insulated substation by EMTP(Electro- magnetic Transient Program). We had simulated the PT ferroresonance between a potential transformer(PT) and an open circuit breaker's grading capacitance. The ferroresonance leads to very large power frequency overvoltages on PT bus and subsequent insulation failure. The large power can be supplied to the PT by the high voltage on the opened circuit due to the grading capacitance and equivalent capacitance of the buses during the ferroresonance. The damping circuit connected on the secondary winding were considered in the model. The actual countermeasure include a saturable inductor and a resistor series-mounted, but the 2 ohms of damping resistance was used in the computationl model.

  • PDF

IEC61850 기반의 2권선 변압기 보호용 IED 개발에 관한 연구 (A development of two-winding transformer protective IED based on IEC61850)

  • 오성민;안용호;송인준;오재훈;권효철;홍정기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.193-194
    • /
    • 2008
  • IEC 61850 기반의 변전소자동화시스템이 세계적으로 많은 관심을 가지면서 IEC 61850 프로토콜 기반의 IED(Intelligent Electronic Device) 개발을 위해 전 세계적으로 많은 노력이 진행되고 있다. 본 연구에서는 IEC 61850 표준규격에서 제안하는 객체 모델링 및 통신프로토콜을 이용하여 2권선 변압기 보호용 IED를 개발하고 그 구현방법을 설명하였다. 구현을 위해 리눅스 OS(Operation System)가 포팅된 통신보드에 MMS(Manufacturing Message Specification), GOOSE(Generic object oriented substation event) 통신모듈을 탑재하였고 데모 시스템을 구성하여 성능을 검증하였다.

  • PDF

디지탈 제어용 CT의 국제규격(IEC 60044-8)에 대한 검토 (A Study about International Standard of Digital Controlled CT)

  • 정영환;김정배;송원표;김덕수;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1794-1796
    • /
    • 2002
  • Conventional current transformers possess many qualities due their simplicity. However, the technological innovations now underway in the field of switchgear and substation control systems tends to underline their drawbacks. New technologies must be developed to provide users with better service quality in terms of precision, operating safety and interoperability. The current transformer presented combines simplicity and the high degree of precision offered by Rogowski coils with the processing possibilities of digital electronics.

  • PDF

GIS 내부의 도체이물질에 의한 불평등 전계 해석 (Analysis of unequal electric field by metal particle in GiS)

  • 박경수;김진;이희복;고영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.531-533
    • /
    • 2000
  • In compared with air insulated switchgear, GIS has a high efficiency and confidence So the transformer substation can be reduced the size to 1/10. Insulation method using $SF_6$ gas has a very excellent insulation characteristics for high pressure equipment but has a characteristics that insulation heredity is changed for internal unequal electric field. So analysis of electromagnetic field in GIS is very important basic data for structure design and trouble diagnosis process. In compared with established method, SNM in this paper observes variation of the electromagnetic field with real time and get result very similar to measurement. In order to know the variation of electromagnetic field distribution for transient response for time and position, variations are observed when the spacer is bonded and metal particles are moving fast.

  • PDF

$SF_6$ 가스중 PET Film의 절연특성 (Insulated Characteristics of PET Film under $SF_6$)

  • 김정달;정장근;주성철;이덕진;박재윤;이용길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2120-2122
    • /
    • 1999
  • $SF_6$ gas has been widely used the gas insulated transmission line, gas insulated transformer and gas insulated substation and Polyester film used as the turn insulation with other material. $SF_6$ gas has been actively studied in domestic and foreign countries. In general, when dielectric surface electric field exceed any electric field strength on air, corona discharge is occurred from the dielectric surface. This paper presents the insulation strength of turn insulation of $SF_6$-PET film studied under application of AC voltage, constitute of the plane to plane with PET Film. The results obtained in experimental are summarized that Partial Discharge Initial Voltage(PDIV) of turn insulation depend on gas pressure, but Breakdown Voltage(BDV) did not depend on gas pressure.

  • PDF

배전시스템센서의 순간전압강하 분석 (Analysis of Voltage Sag on Power Distribution System)

  • 오정환;임성정;윤상윤;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.954-957
    • /
    • 1997
  • In this paper, we analyze the voltage sag caused by reclosing on electric power distribution system. When a fault is on the electric system, a reclosing operation brings a voltage sag on the feeders which is supplied with a common substation transformer. By analyzing the fault wave-form measured in the field, it is showed that a voltage sag is in proportion to a fault current. Also, we propose an adaptive reclosing scheme. This scheme changes the number of reclosing as a function of the magnitude of a fault voltage and the fault type. As the proposed scheme is compared with conventional scheme in the side of voltage sag and permanent fault, it is verified that the proposed scheme is more effective than conventional scheme.

  • PDF

퍼지 로직을 이용한 다중고장 정전복구방안 연구 (Multiple outage service restoration algorithm using fuzzy logic)

  • 최인선;임성일;이승재;하복남;설일호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.187-189
    • /
    • 2003
  • This paper presents new service restoration algorithm to deal with multiple faults such as main transformer fault, whole substation fault and simultaneous faults. The most important consideration of restoration planning for multiple outage areas is efficient use of redundant backup feeders. The proposed algorithm tries to restore all outage loads using outage area ordering method and tie switch exchange method that are newly proposed in this paper.

  • PDF

푸리에 변환을 이용한 다중 재폐로방식에서의 사고전류 특징 추출 (Feature Extraction of Fault Current using Fourier Transform in the Multi-Shot Reclosing Scheme)

  • 오정환;윤상윤;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권2호
    • /
    • pp.50-55
    • /
    • 2000
  • This paper presents the feature extraction of fault currents related to the multi-shot reclosing scheme in the power distribution system. In order to get the fault current waveform, we have measured the fault currents by the fault recorders which have been installed at the secondary side of 154/22.9[kV] substation transformer. These waveforms are classified into temporary and permanent fault. For the classified waveforms, Fourier transform is used to extract the feature of the fault current waveforms. After the waveforms are analyzed by using Fourier transform, the magnitude spectrum and the relative variation of THD (Total Harmonic Distortion) are calculated. And then the relative variation of THD is great in the temporary faults, and is small in the permanent faults.

  • PDF

A Phase-shifter for Regulating Circulating Power Flow in a Parallel-feeding AC Traction Power System

  • Choi, Kyu-Hyoung
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1137-1144
    • /
    • 2014
  • A parallel-feeding AC traction power system increases the power supply capacity and decreases voltage fluctuations, but the circulating power flow caused by the phase difference between the traction substations prevents the system from being widely used. A circuit analysis shows that the circulating power flow increases almost linearly as the phase difference increases, which adds extra load to the system and results in increased power dissipation and load unbalance. In this paper, we suggest a phase shifter for the parallel-feeding AC traction power system. The phase shifter regulates the phase difference and the circulating power flow by injecting quadrature voltage which can be obtained directly from the Scott-connection transformer in the traction substation. A case study involving the phase shifter applied to the traction power system of a Korean high-speed rail system shows that a three-level phase shifter can prevent circulating power flow while the phase difference between substations increases up to 12 degrees, mitigate the load unbalance, and reduce power dissipation.