• 제목/요약/키워드: Transformer Design

검색결과 901건 처리시간 0.032초

전력용(電力用) 변압기(變壓器) 고장전류(故障電流) 감소(減少)를 위(爲)한 중성점(中性点) 리액터 적용(適用) 연구(硏究) (The Application of Neutral Reactors to Limit Through fault Duty on Substation Transformer.)

  • 장종근;김정부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.210-213
    • /
    • 1990
  • This paper presents the countermeasure to present the main transformer of distribution substation from deteriorating and failing due to repeated magnetic force of the transformer winding by ground fault current in 22.9kV multi grounded distribution system. The Winding strength to the short circuit current is designed to be endurable to the stress of over current. But this design is related to the manufactures. In this paper we examine the application of shunt reactor to the neutral point of the low side of the transformer to reduce fault current due to the fault in the distribution lines we have analysed the fault characteristics of the system and calculated the optimum ohmic values of the neutral reactor.

  • PDF

전력증폭부의 광대역 특성 개선을 위한 최적의 부하 임피던스 설계 방안 연구 (A Study on Design of Optimal Load Impedance for Broadband Characteristic Improvement of the Power Amplifier)

  • 이한영
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1166-1173
    • /
    • 2009
  • In this paper, we studied on the power amplifier which has the output of the optimal to 100MHz-2GHz band. Optimal output power match was fabricated using the two types; one is the linear tapering and the other is the impedance transformer. In the case of output power match using linear tapering, output power was 35.35dBm at 2GHz and 31.41dBm at 100MHz. The other case of output match using impedance transformer, output power was 34.8dBm at 2GHz and 33.25dBm at 100MHz. Comparison of the results in the two cases, impedance transformer type present the improved results by l.84dB of output power.

Transformer Core Model and Parameter Estimation for ATP

  • Cho Sung-Don
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권4호
    • /
    • pp.385-389
    • /
    • 2005
  • Power transformers would appear to be simple. However, due to their nonlinear and frequency-dependent behaviors, they can be one of the most complex system components to model. It is imperative that the applied models be appropriate for the range of frequencies and excitation levels that the system experiences. Transformer modeling is not a mature field and newer improved models must be made available in ATP packages. Further, there is a lack of published guidance on recommended modeling approaches. And there is typically not enough detailed design or test information available to determine the parameters for a given model. The purpose of this paper is to develop improved transformer core models for ATP and parameter estimation methods that can efficiently utilize the limited available information such as factory test reports.

압전 변압기 정상상태 특성과 고효율 냉 음극 방전등용 인버터 설계 (Steady-State Characteristics of the Piezoelectric Transformer and the Design of the Piezoelectric Inverter)

  • 권기현;임영철;양승학;정영국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2616-2619
    • /
    • 1999
  • The Backlight inverter used in the laptop computer is designed in this study. It has been difficult for electromagnetic transformer to enhance the efficiency and compact profile. In this study, (l) the piezoelectric transformer(PT) is used for reducing the loss: (2) the volume of core and winding coil are used in electromagnetic transformer, and (3) the zero voltage switching(ZVS) is used in the driver of the resonant circuit. The modified PT for this paper and the equivalent circuit are supported by the simulation program. ZVS is achieved by Half-Bridge inverter circuit. The result of the experiment shows more than 91% improvement in terms of the efficiency.

  • PDF

Unipoled Disk-type 압전변압기의 설계 및 유한요소 해석 (Design and FEM Analysis of Unipoled Disk-type Piezoelectric Transformer)

  • 정성수;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 반도체 재료 센서 박막재료 전자세라믹스
    • /
    • pp.183-186
    • /
    • 2004
  • Unipoled piezoelectric transformers were designed with different input and output area ratios. The voltage step-up ratio increased proportionally with increasing the input area. The piezoelectric transformers operated in each transformer's resonance vibration mode. In this paper, ANSYS(FEM program) was used for analysing piezoelectric transformers. We compared with analysis and experimental results. The voltage step-up ratio showed maximum value in output area of small size. Output characteristics of piezoelectric transformers with various size were simulated. The result of analysis showed 2~7 times higher voltage step-up ratio than a experiment result.

  • PDF

공심 절연변압기를 구비한 반브릿지 공진형 컨버터 (Half-Bridge Resonant Converter with Coreless Isolation Transformer)

  • 허준;전성즙
    • 전기학회논문지
    • /
    • 제66권4호
    • /
    • pp.636-642
    • /
    • 2017
  • Recently, new power devices, SiC and GaN FETs, are commercialized. They are expected to change power electronics environments. They will raise operating frequencies of power electronic equipments. Accordingly, design method will be changed greatly. In this paper, an 1 MHz resonant converter with fully compensated coreless isolation transformer is proposed, where the primary voltage is proportional to the secondary current and the primary current to the secondary voltage. 30 W prototype is constructed and tested, and its usefulness is verified.

평면변압기적용 Forward DC/DC Converter (Forward DC/DC Converter Using Planar Transformer)

  • 최선호;박진영;박성수;김은수;이해연;김현식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.149-153
    • /
    • 2003
  • In this paper, the design and implementation of a high power(300W) forward converter using a planar transformer is presented. The overall size and volume of the converter is decreased by replacing a planar transformer in stead of using a conventional winding transformer. Due to the decreased size and volume, power density of the applied forward converter is increased. Also, in this paper, the 300W ZVS forward converter with active clamp snubber circuit is compared to the 300W hard switching forward converter.

  • PDF

제안된 평면변압기를 이용한 LLC 공진컨버터 (LLC Resonant Converter using Proposed Planar Transformer)

  • 이승민;김은수;정봉근;이재삼;김유선;허동영
    • 전력전자학회논문지
    • /
    • 제17권2호
    • /
    • pp.121-128
    • /
    • 2012
  • In this paper, a new planar transformer with a novel core configuration that can regulate the leakage inductance is proposed and described in detail. In order to design the slim size power system for flat panel TV, Two planar transformers applied to LLC resonant converter are connected in series at primary and in parallel by the center-tap winding at secondary. In this paper, a 300W low profile LLC resonant converter was built and tested to verify the proposed planar transformer.

Investigation of Rise Time and Overshoot in Pulse Transformers with Different Topologies for Electromagnetic Trigger of SCRs

  • Lv, Gang;Zeng, Dihui;Zhou, Tong
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.902-909
    • /
    • 2018
  • This study investigates the influences of different core parameters on the dynamic performances, such as rise time and overshoot, in pulse transformers for the triggering circuit of SCRs. First, a simplified transformer equivalent circuit, which emerges from a standard transformer equivalent circuit, is developed to analyze the step response. Second, the relations between the dynamic performances and the parasitic parameters are calculated by the simplified equivalent circuit. Third, the variations of rise time and overshoot, which are vital to the stability of triggering SCRs, with different core parameters, such as mechanic dimensions and topologies, are comprehensively investigated by analyzing the parasitic parameters. Finally, prototype transformers are fabricated to experimentally validate the analysis. The presented method can practically instruct the design of a pulse transformer for triggering SCRs.

유한요소법에 의한 초고압변압기권선의 충격파전위분포설계에 관한 연구 (Study on Surge Voltage Distribution Design for UHV Transformer Windings by Finite Element Method)

  • 황영문;이일천
    • 전기의세계
    • /
    • 제28권11호
    • /
    • pp.45-51
    • /
    • 1979
  • Finte element methods are developed for the initial distribution problems which contain the surge potential circuits of high voltage transformer windings. The initial distribution of surge voltages in transformer windings are useful to the work to a practical engineering basis. However, the conventional methods of analyzing them so far are much complicated for practical designs. In this paper, the ability to solve surge potential field problems underlies the development of descreting methods to a lodal capacitive distribution-coefficients for determing the surge voltage relationship among a set of transformer coils. A practical example-the modeling of an antioscillation shield coil winding and hisercap winding is used to illustrate and evaluate these methods.

  • PDF