• 제목/요약/키워드: Transformer Design

검색결과 901건 처리시간 0.028초

진공 주유시 변압기 탱크의 소성발생 예측 (Prediction of the Plastic Deformation of the Transformer Tank at the Time of Vacuum Oiling)

  • 이정훈;김정찬;최재필
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권12호
    • /
    • pp.540-545
    • /
    • 2005
  • The transformer tank is pressurized by atmosphere at the time of vacuum oiling and, plastic deformation occurs at the section of stress concentration on transformer tank at this time. It is important to predict where the sections of stress are in order to prevent deformation and to add reinforcement. This paper presents prediction results where the sections of stress are occurred and whether plastic deformation occur or not, using structure analysis program(ANSYS-design program).

50 kV, 10kW 소형 고주파 전원장치 변압기 개발 (Development of a Compact 50 kV, 10 kW Transformer for High Frequency Switch Mode)

  • 손윤규;오종석;장성덕;조무현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2027-2029
    • /
    • 1998
  • We have developed a compact high frequency switch mode converter (HFSMC) power supply with DC 50 kV output voltage and 10 kW output power. Since the inverter circuit uses 25 kHz rescharging scheme, the current is flowing with t kHz. For the efficient output voltage transform performed a simple design process using the transformer principle and the commercial specification. For the DC 50 kV output, we employed 7 pa windings of secondary coils for the series stac connection of the output with full-bridge rectifi In this paper the design detail and the test re the high frequency transformer together with HFSMC power supply are presented.

  • PDF

권철심변압기의 등가이방성모델을 이용한 최적설계 (Optimal Design of Wound core type Transformer by Equivalent Anesotropic Block)

  • 임달호;권병일;박승찬;이중호;김성영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.156-158
    • /
    • 1994
  • The analysis of the thin lamination model of the amorphous transformer by FEM requires many region, divisions and much calculating tine, and it has difficulty in calculating for mordern computer. A new method which is simulated by a solid but anisotropic block with the magnetic permeabilities in two orthogonal directions selected to account for the presence of the laminations. [1] Based on this equivalent anisotropic block model, we analyzed the iron loss of the amorphous transformer by FEM, and presented an optimal design example of core dimensions for minimizing the iron loss.

  • PDF

6.6kV급 선박용 고압 건식 변압기 최적 설계를 위한 전자계 해석 (Electromagnetic Analysis of 6.6kV Main Transformer for a Vessel)

  • 강문식;김경호;구성회;조윤현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.818-820
    • /
    • 2004
  • This paper is described the insulation design and 3-D electromagnetic analysis of 6.6kV main transformer for a vessel by F.E.M.. To obtain the optimal design of insulation structure, the electric field stress is analyzed and estimated the proposed model A and B for the characteristics investigation according to the insulation thickness and position. And the performance characteristics of 6.6kV transformer are estimated as the equivalent circuit parameters computed by F.E.M. analysis.

  • PDF

비접촉식 배터리 충전 장치용 Half-Bridge 직렬 공진 컨버터 분석 및 설계 (Analysis and Design of Half-Bridge Resonant Converter for Non-Contact Battery Charger)

  • 김창균;서동현;유정식;박종후;조보형
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권4호
    • /
    • pp.265-271
    • /
    • 2000
  • A non-contact battery charger for cellular phone is designed using half-bridge series resonant converter. This converter utilizes series resonance to reduce the undesirable effect of large leakage inductance of the detachable transformer and ZVS operation can reduce switching loss and switching noise. In this paper, analysis and design procedure of half-bridge series resonant converter with detachable transformer is presented. The input voltage is 85VAC∼270VAC, and the output voltage and current is 4.1V and 800mA, respectively. Furthermore, a method of calculating the secondary current of the transformer to control the battery charging current in the constant current charging mode is proposed. The performance of the charger is verified through experiments.

  • PDF

퓨즈가 내장된 엘보접속재의 설계 (Design of Fuse Mounted Elbow Connector)

  • 최경선;이철호;송일근;권태종;권영복;한명관
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.383-386
    • /
    • 2000
  • Fuse mounted elbow connector used for pad mounted transformer was designed and investigated. Requirements of electrical ratings such as partial discharge, ac withstand voltage and impulse voltage and material properties were proposed in accordance with IEEE 386 and pre-standard (PS) 147-219∼229 of KEPCO. The connector can be jointed with pad mounted transformer and current limiting fuse which is installed inside of the connector easily replaced with new one in the case of breakdown of the fuse. Electric field analysis was also introduced in other to verify the reliability of the design.

  • PDF

Magnetic Field Analysis of 1 MVA HTS Transformer Windings

  • Park, Chan-Bae;Kim, Woo-Seok;Lee, Sang-Jin;Han, Jin-Ho;Park, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won;Hahn, Song-Yop
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.66-70
    • /
    • 2003
  • In a HTS transformer, the perpendicular component of magnetic flux density ($B_r$) applied to HTS tapes of pancake windings becomes larger than that of solenoid winding, thereby decreasing the critical current in the HTS tapes. This paper introduces several methods to reduce $B_r$ applied to the HTS tapes in the transformer with double pancake windings by changing winding arrangements and the relative permeability of flux diverters. We have conducted a winding design for a single-phase 1MVA 22.9kV/6.6kV HTS transformer. We observed a change of $B_r$ due to a variation of gap-length between the high voltage windings and the low voltage windings, reciprocal arrangement and an increase of the number of the high voltage pancake. We also observed a change of Br on the HTS tapes due to variation of the relative permeability of flux diverters placed between the high voltage winding and the low voltage winding. Finally, we have designed a 1MVA 22.9kV/6.6kV HTS transformer winding using suggested methods and calculated transformer parameters by the 3D finite element method.

표면 임피던스 경계조건을 이용한 몰드변압기 Tie-plate 손실 최소화에 관한 연구 (A Study on the Minimization of Tie-plate Loss of Cast Resin Transformer using Surface Impedance Boundary Condition)

  • 황성률;신판석
    • 전기학회논문지
    • /
    • 제66권9호
    • /
    • pp.1334-1340
    • /
    • 2017
  • In this paper, a tie-plate shape is optimized by using the numerical technique to reduce the stray load loss of the tie-plate which is a mechanical structure for assembling and supporting of the transformer core. The eddy current loss of the structure is calculated by an electromagnetic field FEM program and the results are compared with 4 different shapes of tie-plates. Since the thickness of the tie-plate is very thin, and the skin depth is very small, the number of FE elements for 3-D transformer model is too big to solve. So, the surface impedance boundary condition (SIBC) is used to reduce the system matrix size and its computing time. To verify the method a 2.5 MVA 22,900/380V distribution transformer is simulated using one objective function and three design variables with some constraints. The final optimized tie-plate has three slots of 6 mm width and 23 mm gap, and the loss is reduced by 75 %. Consequently, the proposed algorithm seems to be considerably applicable to electric machinery as well as power transformer.

유전 및 압전특성에 따른 LCD Backlight용 압전 트랜스포머의 출력전력특성 (Output Power characteristics of the Piezoelectric Transformer for LCO Backlight with Piezoelectric and Piezoelectric Properties)

  • 민석규;류주현;정회승;홍재일;윤현상;손은영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.852-856
    • /
    • 2000
  • In this paper, we investigated the output power, step-up ratio and efficiency properties of piezoelectric transformer with dielectric and piezoelectric characteristics of manufactured ceramics. The piezoelectric transformers with $2.0$\times$10$\times$48[$mm^3$] size were fabricated and its electrical properties were measured. When output power of 6W was constantly maintained, T2 piezoelectric transformer showed the minimum temperature rise of $9(^{\circ}C)$ at $150(K\Omega)$ load resistance. However, T1 piezoelecric transformer showed the temperature rise of $7.2(^{\circ}C)$ at $200(K\Omega)$ load resistance. The 6[w] CCFL (Cold Cathode Fluorescent Lamp) was successfully driven by T1 and T2 piezoelectric transformer but, its temperature rise $\Delta$T[$^{\circ}C)$] was generated more than $20(^{\circ}C)$. It is concluded that we have to design the piezoelectric transformers so that its output impedance correspond to the load impeadance, including any stray capacitance.

  • PDF

코어 종류에 따른 PCS 인덕터와 트랜스포머 손실 분석 (Loss analysis to the various kinds of core for PCS inductor and transformer)

  • 양승대;심재휘;최주엽;송승호;최익;안진웅;이동하
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.22-30
    • /
    • 2011
  • In recently, inductor and transformer is the common device using widely in the photovoltaic system and power electronics. Therefore, each inductor and transformer has different core loss and iron loss depending on the size and kinds of core materials, it is important to analyze loss characteristics for better transformer efficiency. This paper offers an efficiency calculation method for PCS inductor and transformer loss, and different kinds of core materials are analyzed for optimized PCS design.