• 제목/요약/키워드: Transformer

검색결과 4,292건 처리시간 0.026초

Study on the Transfer Functions for Detecting Windings Displacement of Power Transformers with Impulse Method

  • Shon, Chae-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.876-883
    • /
    • 2012
  • The paper investigates three types of transfer function methods for detecting displacements of winding in a model transformer. To acquire these transfer functions, the measuring method of input voltage, current and its response is used in impulse method. The applied impulse voltages had three rising times, which were short rising time (less than 0.6 ${\mu}s$), medium rising time (about 0.8 ${\mu}s$) and long rising time (about 1 ${\mu}s$) in front waves. Every 10 measurements of voltage and current waves were averaged from 50 measurements of voltage and current waves. These transfer functions were tested in normal, 24mm elevated and 48mm elevated windings conditions and were analyzed with correlation coefficients and spectrum deviations. In the analysis, the results depend on the types of transfer functions and the rising times of input voltages.

Primary Restorative Transmission Line Selection for Myanmar's Electric Power System

  • Kim, Yong-Hak;Song, In-Jun;Jang, Byung-Tae;An, Yong-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.191-196
    • /
    • 2010
  • Power system restoration following a massive or complete blackout starts with energizing the primary restorative transmission system. During this primary restoration process, unexpected overvoltage may happen due to nonlinear interaction between the unloaded transformer and the transmission system. In the case of the Myanmar electric power system, there are so many wide outage experiences, including complete blackout cases, caused by 230kV line faults and so on. Consequently, Myanmar's system operators have been well trained to deal with wide blackouts. Howver, system blackout restoration has been conducted by relying on the experience of only a few specialists. So, more scientific analysis is required to meet the requirements necessary to ensure fast and reliable system restoration. This paper presents analytical results on the primary restorative transmission system of Myanmar, focusing on the problems during the early restoration process. Methodologies are presented that handle load pick-up, terminal voltage and the reactive capability limitation of black-start generators to compensate the Ferranti effect. Static and dynamic simulation with the PSSolution and EMTDC programs respectively for the six cases are performed in order to select the primary restorative transmission lines.

동적 이벤트를 고려한 수주생산환경의 계층적 생산계획 및 통제 시스템 (A Hierarchical Production Planning and Control System in a Make-to-Order Environment with Dynamic Events)

  • 장길상;김재균
    • 산업공학
    • /
    • 제14권1호
    • /
    • pp.9-19
    • /
    • 2001
  • Production planning and control system plays an important role in manufacturing companies because it determines all production capacity planning, material procurement planning, and production scheduling which are needed in the process of producing products. Many researches on production planning and control system have been conducted for many manufacturing companies for recent decade. But, a considerable research achievement has mainly been obtained on the forecast-driven production for a make-to-stock and an assemble-to-order. The reason is that there are some hardships such as difficulties of standardizing product information, the frequent changes of design and material, and the unexpected dynamic events that influence the production of customer's order in a make-to-order or an engineering-to-order environments. By these characteristics and their complexities, some studies for production planning and control system in a make-to-order environment are presented recently. In this paper, we present the framework of the hietachical production planning and control for a make-to-order environment with dynamic events. In order to illustrate the usefulness of the proposed framework for a hietachical production planning and control, the information system for a make-to-order production was implemented with the object of the company of producing electricity transformer.

  • PDF

Optimal DG Placement in a Smart Distribution Grid Considering Economic Aspects

  • Buaklee, Wirote;Hongesombut, Komsan
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1240-1247
    • /
    • 2014
  • The applications of Distributed Generation (DG) in a smart distribution grid environment are widely employed especially for power balancing and supporting demand responses. Using these applications can have both positive and negative impacts on the distribution system. The sizing and location of their installations are the issues that should be taken into consideration to gain the maximum benefit from them when considering the economic aspects. This paper presents an application of the Bat Algorithm (BA) for the optimal sizing and siting of DG in a smart distribution power system in order to maximize the Benefit to Cost Ratio (BCR), subjected to system constraints including real and reactive power generation, line and transformer loading, voltage profile, energy losses, fault level as well as DG operating limits. To demonstrate the effectiveness of the proposed methodology and the impact of considering economic issues on DG placement, a simplify 9-bus radial distribution system of the Provincial Electricity Authority of Thailand (PEA) is selected for the computer simulation to explore the benefit of the optimal DG placement and the performance of the proposed approach.

A High Efficiency LLC Resonant Converter-based Li-ion Battery Charger with Adaptive Turn Ratio Variable Scheme

  • Choi, Yeong-Jun;Han, Hyeong-Gu;Choi, See-Young;Kim, Sang-Il;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.124-132
    • /
    • 2018
  • This paper proposes an LLC resonant converter based battery charger which utilizes an adaptive turn ratio scheme to achieve a wide output voltage range and high efficiency. The high frequency transformer of the LLC converter of the proposed strategy has an adaptively changed turn ratio through the auxiliary control circuit. As a result, an optimized converter design with high magnetizing inductance is possible, while minimizing conduction and turn-off losses and providing a regulated voltage gain to properly charge the lithium ion battery. For a step-by-step explanation, operational principle and optimal design considerations of the proposed converter are illustrated in detail. Finally, the effectiveness of the proposed strategy is verified through various experimental results and efficiency analysis based on prototype 300W Li-ion battery charger and battery pack.

Narrow Resonant Double-Ridged Rectangular Waveguide Probe for Near-Field Scanning Microwave Microscopy

  • Kim, Byung-Mun;Son, Hyeok-Woo;Cho, Young-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.406-412
    • /
    • 2018
  • In this paper, we propose a narrow resonant waveguide probe that can improve the measurement sensitivity in near-field scanning microwave microscopy. The probe consists of a metal waveguide incorporating the following two sections: a straight section at the tip of the probe whose cross-section is a double-ridged rectangle, and whose height is much smaller than the waveguide width; and a standard waveguide section. The advantage of the narrow waveguide is the same as that of the quarter-wave transformer section i.e., it achieves impedance-matching between the sample under test (SUT) and the standard waveguide. The design procedure used for the probe is presented in detail and the performance of the designed resonant probe is evaluated theoretically by using an equivalent circuit. The calculated results are compared with those obtained using the finite element method (Ansoft HFSS), and consistency between the results is demonstrated. Furthermore, the performance of the fabricated resonant probe is evaluated experimentally. At X-band frequencies, we have measured the one-dimensional scanning reflection coefficient of the SUT using the probe. The sensitivity of the proposed resonant probe is improved by more than two times as compared to a conventional waveguide cavity type probe.

Theoretical and Experimental Analysis of Extremely Low Frequency Magnetic Field in the Vicinity of the Transformer Station of Overhead Power Lines

  • Ghnimi, Said;Rajhi, Adnen;Gharsallah, Ali;Bizid, Youssef
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1655-1662
    • /
    • 2018
  • This paper studies the magnetic fields between the power lines which are finite length and other ones which are infinitely long around the first tower in the proximity of the power transformers. They will be used as a source of disturbance applied to the power line. The method applied in this study was gradual; develop the theoretical formulation of the magnetic fields of these lines which are finite length and other ones which are infinitely long, examine the effects of different couplings between the different neighboring lines and the distribution transformers on behavior of magnetic fields. The method also focused on the experimental results analyzing the magnetic fields which will be used as a source applied to the auditory implants EMC. The theoretical and experimental results were compared and discussed for three power lines (90kV, 150kV and 225kV) near the power station, and it proved the effect of these substations on the simulated and measured results of the magnetic field. The maximum intensities of magnetic fields measured at the height of 1m from the ground for the circuit of three lines close to each substation were significantly lower than the ICNIRP reference levels for occupational and non occupational exposures.

비접촉 충전 에너지 전달을 위한 포워드형 ZVS MRC에 관한 연구 (The Study on Forward ZVS MRC for Non-contact Charging Energy Transmission)

  • 김영길;김진우;김태웅;원영진;이성백
    • 조명전기설비학회논문지
    • /
    • 제15권2호
    • /
    • pp.64-72
    • /
    • 2001
  • 본 논문에서는 비접촉 충전 에너지 전달을 위한 포워드 ZVS MRC(Zero Voltage Switching Multi Resonant Converter)를 제안하였다. 포워드 ZVS MRC는 기생성분을 흡수하는데 그리고 스위칭손실을 최소화하는데 효과적이다. 이것은 높은 주파수동작에 적합하며 따라서 이것을 비접촉 충전에너지 전달에 적용하였다. 사용된 컨버터는 분리형 트랜스포머와 동기식정류기를 이용하였다. 갭의 크기에 따른 결합계수(k), 누설인덕턴스, 결합인 덕턴스 그리고 공진 주파수를 측정하였다. 구해진 값을 이용하여 회로를 설계, 구현하였으며 제안된 회로는 PSPICE로 시뮬레이션하였고 실험하였다. 주스위치의 전압 스트래스와 출력전력을 측정하였으며 제안된 컨버터가 비접촉 충전 에너지 전달에 적합함을 보였다.

  • PDF

부분방전 신호와 잡음의 분리 (Separation of Partial Discharge Signals and Noise)

  • 이승환;유치형;정찬수;김재철;이상철;정양웅
    • 조명전기설비학회논문지
    • /
    • 제13권1호
    • /
    • pp.21-30
    • /
    • 1999
  • 전력용 변압기의 절연 열화를 탐지하기 위한 연구가 오래 전부터 연구되어 왔으며 절연유에 함유된 연소성 가스분석 기술이 주로 활용되고 있다. 최근들어 고압 대용량화에따른 사고 파급효과가 커지게 되면서 on-line 탐지시스템의 필요성이 대두되면서 부분방전 신호 검출법이 연구되기 시작하였다. 본 연구는 부분방전 신호 검출법 중에서 탐촉자의 탈착이 용이한 초음파 신호 측정법에서 가장 큰 문제점인 잡음신호 분리를 위한 연구이다. 신호원의 개수와 위치를 측정할 수 있으므로 측정된 초음파 신호가 부분방전에 의한 것인지 외부 잡음인지를 구별할 수 있으며 변압기의 절연열화 판단에 한층 신뢰성을 향상시킬 수 있게 되었다.

  • PDF

DSP를 이용한 주상변압기 유전정접 측정기법 연구 (Research of Tan$\delta$ Measurement on Pole Transformers using DSP)

  • 김재철;이보호;김언석;최도혁;이수길
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권2호
    • /
    • pp.110-118
    • /
    • 1997
  • 본 논문은 DSP를 이용한 주상변압기 유전정접($tan\;delta$) 활선 측정기법을 제안하였다. 변압기 내부에 콘덴서를 삽입한 후 센서에 전압을 인가하고, 인가된 전압과 콘덴서에 흐르는 전류를 측정하여 본 논문에서 제안한 상호 상관 함수 기법을 이용하여 유전정접을 구하였다. 측정의 성능 향상을 위해 TMS320C31 DSP 보드를 사용하였으며 상호 상관 함수 기법을 사용하였다. 또한 노이즈 영향을 검토하기 위해 컴퓨터 시뮬레이션을 수행하였다. 본 연구의 검증을 위해 본 논문에서 구현한 측정장치와 Schering bridge을 사용하여 비고 실험을 하였다. 실험 결과 주상 변압기 절연진단에 충분히 활용할 수 있음을 알 수 있었다.

  • PDF