• 제목/요약/키워드: Transfer resistance

검색결과 1,291건 처리시간 0.03초

공진 코일의 크기와 부하 저항이 자계 공명 무선 전력 전송 장치의 전달 효율에 주는 영향에 관한 연구 (A Study on the Effect of Resonant Coil Size and Load Resistance on the Transmission Efficiency of Magnetic Resonance Wireless Power Transfer System)

  • 박정흠
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.45-51
    • /
    • 2012
  • In this paper, the wireless power transfer system using the magnetic resonance was designed and the effect of resonant coil radius and load resistance to this system was analyzed by the circuit analysis method. As a result, the calculated transmitted-power is similar to measured one, and the coil size has a small effect to the coupling coefficients in the resonant frequency band. In addition, the fact that the calculated transmitted-power according to the source frequency is similar to measured one confirms that the circuit analysis methode in this paper is valid. The input side transmission efficiency ${\eta}_i$ including only the loss in the power transfer circuit is almost 90[%] with the large coil in the 10[cm] transfer distance, and 65[%] with the small coil in 1[cm]. The source side transmission efficiency ${\eta}_s$ is 30~40[%] at both coil when load resistance below 4.7[${\Omega}$] has been connected. Considering that the maximum ${\eta}_s$ is 50[%], this is valid in the practical applications.

Integral Analysis of the Effects of Non-absorbable gases on the Heat Mass Transfer of Laminar Falling Film

  • Kim, Byong-Joo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.56-66
    • /
    • 1998
  • The absorption process of water vapor in a liquid film is an important process in LiBr-Water absorption system. The composition of the gas phase, in which a non-absorbable gas is combined with the absorbate, influences the transport characteristics. In the present work, the absorption processes of water vapor into aqueous solutions of lithium bromide in the presence of non-absorbable gas are investigated. The continuity, momentum, energy and diffusion equations for the solution film and gas are formulated in integral forms and solved numerically. It is found that the mass transfer resistance in gas phase increases with the concentration of non-absorbable gas. However the primary resistance to mass transfer is in the liquid phase. As the concentration of non-absorbable gas in the absorbate increases, the interfacial temperature and concentration of absorbate in solution decrease, which results in the reduction of absorption rate. The reduction of mass transfer rate is found to be significant for the addition of a small amount of non-absorbable gas to the pure vapor, especially at the outlet of tube where the non-absorbable gas accumulates. At higher non-absorbable gas concentration, the decrease of absorption rate seems to be linear to the concentration of non-absorbable gas.

  • PDF

철도수단이 내재된 통행사슬의 환승저항 추정방안 - 수도권 교통카드자료를 활용하여 - (Transfer Impedence of Trip Chain with a Railway Mode Embedded - Using Seoul Metroplitan Transportation Card Data -)

  • 이미영;손지언
    • 대한토목학회논문집
    • /
    • 제36권6호
    • /
    • pp.1083-1091
    • /
    • 2016
  • 본 연구는 대중교통카드자료를 이용해서 수도권 지역간 대중교통통행에서 승객들이 겪는 환승시간, 환승회수의 환승저항을 분석한다. 현재 교통카드자료는 버스와 철도를 이용하는 수단통행을 5회까지 Trip Chian으로 기록하여 수단간 환승과 관련된 정보는 쉽게 파악된다. 그러나 수도권 교통카드는 도시철도의 통행에서 발생하는 환승역 정보를 포함하고 있지않아 Trip Chain에서 승객이 경험하는 환승저항이 저평가되는 문제가 존재한다. 따라서 철도통행에 대하여 승객행태를 반영하는 경로선택모형으로 구축하여 환승시간과 환승회수를 반영하면 온전한 환승저항의 설명력을 갖게된다. 연구방법으로서, 우선 수도권 대중교통환승에 대한 개념을 정립하여 도시철도가 포함되는 수단이용의 경우 교통카드자료의 환승저항 개념을 새롭게 정립한다. 또한 Trip Chain내에 철도의 경로선택모형을 구축하여 환승시간 및 환승회수를 대상으로 통행저항을 재평가하여 설정한다. 그리고 버스 및 도시철도 정류장 좌표를 행정동단위의 소죤 및 시군구 단위의 중죤으로 일치시키기 위해서 빅노드를 운영하는 방법을 채택한다. 마지막으로 수도권의 지역간 통행에서 철도수단이 한번 포함된 통행사슬에 대한 사례연구를 통하여 결과의 타당성을 논의한다.

이질균속의 항균제 내성 (Antimicrobial Drug Resistance in Shigella cultures Isolated in Korea (1983))

  • 정태화;이명원;이복권;김기상;이훈구;이연태;홍성노
    • 대한미생물학회지
    • /
    • 제19권1호
    • /
    • pp.25-33
    • /
    • 1984
  • One hundred and forty strains of Shigella cultures isolated from the twelve hygiene laboratories of cities and provincial level and general hospital laboratories in 1983, and were tested for their resistance to 13 antimicrobial drugs and their R-Plasmid transfer. One hundred and forty (100%) of isolates were susceptible to amikacin, gentamicin, tobramycin, a total of 94.3% of all shigella isolates were resistant to 1 or more of the 13 antimicrobial agents tested. The most commonly found resistance was to chloramphenicol (94%), followed by streptomycin (93%), tetracycline (92%), piperacillin (90%), ampicillin (83%), cefoperazone (42%), nalidixic acid (14%), cephalothin (17%), rifampicin (22%), and kanamycin (6%). Sixty percent of strains among 140 were resistant to ampicillin, chloramphenicol, streptomycin, tetracycline at same time. The transfer of drug resistance by conjugation was tested and 94 strains (94.3%) which were resistant to one or more drugs were found to transfer their drug resistance to E. coli.

  • PDF

착상조건하에서 평행 평판 열교환기의 열 및 물질전달 (Heat and Mass Transfer of Parallel Plate Heat Exchanger under Frosting Condition)

  • 이관수;이태희;김우승
    • 설비공학논문집
    • /
    • 제6권2호
    • /
    • pp.155-165
    • /
    • 1994
  • In this study, the following factors are investigated from experiments for a vertical parallel plate heat exchanger under the frosting condition ; the growth of frost layer, the characteristics of heat and mass transfer, the change of mass flow rate of the air passing through the heat exchanger, and the pressure drop of the air in the heat exchanger. The amount of heat and mass flux of water vapor transferred from the air stream to the heat exchanger surface is large at the early stage of frosting and then decreases dramatically, and the extent of decreasing rate becomes moderate with time. The frost layer formed near the inlet of the heat exchanger is thicker and denser than that formed near the outlet. It is found that the gradient of the amount of frost along the flow direction increases with time. In the early period of frost formation, the thermal resistance between the air and the cooling plate increases dramatically and then the extent of change decreases with time. Initially the convective thermal resistance is dominant. Then, while the convective thermal resistance decreases with time, the conductive thermal resistance continues to increase with time and finally the conductive thermal resistance becomes dominant.

  • PDF

Dynamic Electrochemical Impedance Spectroscopy를 이용한 스테인리스 강의 계면 저항 분석 (In-depth Investigation on Interfacial Resistance of Stainless Steel by Using Dynamic Electrochemical Impedance Spectroscopy)

  • 허정호;이용헌;신헌철
    • 대한금속재료학회지
    • /
    • 제47권10호
    • /
    • pp.644-651
    • /
    • 2009
  • The passivation (or deactivation) of a metal surface during oxide film formation has been quantitatively explored for a ferritic stainless steel by using dynamic electrochemical impedance spectroscopy (DEIS). For this purpose, the electrochemical impedance spectra were carefully examined as a function of applied potential in the active nose region of the potentiodynamic polarization curve, to separate the charge transfer resistance and oxide film resistance. From the discrepancy in the potential dependence between the experimental charge transfer resistance and the semi-empirically expected one, the degree of passivation could be quantitatively estimated. The sensitivity of passivation of the steel surface to anodic potential, which might be the measure of the quality of the oxide film formed under unit driving force or over-potential, decreased by 31% when 3.5 wt% NaCl was added to a 5 wt% $H_2SO_4$ solution.

말뚝-지반 상호작용을 고려한 수정된 하중전이함수법 제안 (Load-Transfer Analysis by Considering Coupled Soil Resistance)

  • 설훈일;정상섬;김영호
    • 대한토목학회논문집
    • /
    • 제28권6C호
    • /
    • pp.359-366
    • /
    • 2008
  • 말뚝의 하중전이거동 및 변형특성 해석을 위해 하중전이함수법이 널리 사용된다. 본 연구에서는 말뚝-지반의 상효작용 즉, 지반의 연속성을 고려한 하중전이해석에 고찰하였으며, Mindlin 해를 이용하여 이를 고려함으로써 말뚝의 실제 거동에 보다 부합되도록 수정된 하중전이 해석방법을 제안하였다. 이를 통해 말뚝-지반 상호작용의 영향인자인 말뚝직경-지반계수의 비$(D/E_s)$과 주면마찰력-재하하중의 비$(R_s/Q)$를 고려할 수 있었다. 제안된 하중전이함수법의 타당성을 검증하기 위하여 현장재하시험 사례와의 비교분석 결과, 제안된 해석방법은 암반 근입 현장타설말뚝의 하중-침하 거동 및 하중전이특성을 적절히 예측함을 알 수 있었다.

테프론 코팅 전열관 표면으로의 열 및 물질 전달 특성에 관한 실험적 연구 (Experimental Study on the Characteristics of Heat and Mass Transfer on the Teflon Coated Tubes)

  • 이장호;김형대;김정배;김무환
    • 대한기계학회논문집B
    • /
    • 제27권8호
    • /
    • pp.1051-1060
    • /
    • 2003
  • The heat and mass transfer on two kinds of tube surfaces (bare stainless steel tube and Teflon coated tube) in steam-air mixture flow are experimentally studied to obtain design data for the heat exchanger of the latent heat recovery from flue gas. In the test section, 3-tubes are horizontally installed, and steam-air mixture is vertically flowed from the top to the bottom. The pitch between tubes is 67mm, the out-diameter of tube is 25.4mm, and the thickness is 1.2mm ; blockage factor (cross sectional tube area over the cross sectional area of the test section) is about 0.38. All of sensors and measurement systems (RTD, pressure sensor, flow-meter, relative humidity sensor, etc.) are calibrated with certificated standard sensors and the uncertainty for the heat transfer measurement is surveyed to have the uncertainty within 7%. As experimental results, overall heat transfer coefficient of the Teflon (FEP) coated tube is degraded about 20% compared to bare stainless tube. The degradation of overall heat transfer coefficient of Teflon coated tube comes from the additional heat transfer resistance due to Teflon coating. Its magnitude of heat transfer resistance is comparable to the in-tube heat transfer resistance. Nusselt and Sherwood numbers on Teflon (FEP) coated surface and bare stainless steel surface are discussed in detail with the contact angles of the condensate.

젖소 유방염유래(乳房炎由來) 장내세균(腸內細菌)의 약제내성(藥劑耐性) 및 R. Plasmids (Drug Resistance and R. Plasmids of Enterobacteria Isolated from Bovine Udder Infections)

  • 박청규
    • 대한수의학회지
    • /
    • 제21권1호
    • /
    • pp.25-31
    • /
    • 1981
  • A total of 250 enteric bacteria (148 Escherichia coli, 41 Klebsiella pneumoniae, 46 Enterobacter spp. and 15 Proteus spp.) isolated from bovine udder infections in 1979 through 1980 were examined for drug resistance and prevalence of R. plasmids. The drug tested were streptomycin (SM), kanamycin (KM), ampicillin (AP), chloramphenicol (CP), tetracycline (TC), gentamicin (GM), oxolinic acid (OA) and nalidixic acid (NA). The detection of R. plasmids was performed with Escherichia coli ML 1410 NAr as the recipient. Of the 148 Escherichia coli isolated, 68(45.9%) were found to be resistant to one or more drugs tested, and about 50% of the resistant strains were multiply resistant. of the 68 drugresistant strains, 13(19.1%) were found to carry R. plasmids which were capable of performing a conjugal transfer. CP resistance was transfered together with the other resistance. Of 41 strains of Klebsiella pneumoniae isolated, 90.2% were resistant to the drugs, alone or in combination thereof. Strains resistant to AP and TC were 63.4%, and 48.8%, respectively. R. plasmids were detected in 78.4% of the drug-resistant strains, and these strains transfered all or a part of their drug resistance pattern. AP and CP resistance were transfered in 100% of AP and CP-resistant strains. Eleven (37.9%) of 29 R. plasmids showed a thermosensitive transfer. Of the 46 strains of Enterobacter spp. isolated, 37(80.4%) were resistant to the drugs tested. A high percentage of resistance was noted for AP(65.2%). All strains resistant to four or more drugs transferred their resistances to Escherichia coli ML 1410, but strains resistant to three or fewer drugs did not transfer the resistances. All of the 15 Proteus strains isolated were resistant to more than two drugs. of them, 6 were quadruple resistance to SM, KM, CP and TC, and 9 were double one to AP and TC. Three (20.0%) of the drug-resistant isolates had R.plasmids conferring AP and TC resistance. GM, OA and NA of the drugs tested were very active to all of 250 Gram-negative enteric bacteria isolated from bovine udder infections.

  • PDF

자동차용 마찰재에 사용되는 흑연과 마그네시아에 따른 전이막과 마찰특성에 관한 연구 (The Effects of Graphite and Magnesium Oxide in Automotive Friction Materials on Friction and Formation of Transfer Film)

  • 배은갑;윤장혁;장호
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.226-234
    • /
    • 2002
  • A systematic study of the role of transfer films on friction properties was performed with various temperatures in the brake system. An NAO friction material specimens containing 9 ingredients were tested using a pad-on-disk type friction tester A new method of measuring the transfer film thickness was developed by considering the electrical resistance of the transfer film using a 4-point probe technique. The properties of transfer film such as surface morphology and film distribution vaied according to the relative amount of graphite and magnesium oxide. By using SEM, it was possible to obtain information about the chemical composition of the transfer film. Results showed that there detected a threshold value of the relative amount of a two active materials to maintain a certiain thickness of a transfer film. Results also showed that formation of friction layer generated on the friction surface was strongly affected by chemical action of two ingredients during sliding due to chemical reaction of solid lubricants at different interface temperature. The results suggested that no apparent relationship between transfer film thickness and the average friction coefficient was founded and friction characteristics were affected more by the property of the solid lubricant and abrasive in the material.

  • PDF