• 제목/요약/키워드: Transfer resistance

검색결과 1,286건 처리시간 0.028초

CPU 냉각을 위한 적층형 히트싱크의 방열 특성 연구 (A Study on the Heat Dissipation Characteristics of Layered Heat Sink for CPU Cooling)

  • 이규칠;김종하;윤재호;박상일;최윤호;권오경
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.182-187
    • /
    • 2006
  • This research presented the heat resistance characteristics of heat sink which is newly designed through the experiment. For the same volume and base plate of heat sinks, the experiment of heat transfer characteristics was conducted for forced convection of layered type heat sink. The heat transfer and pressure drop characteristics of the layered type heat sink were compared for the various kinds of fin pitches, fin heights and heights of heat sink. The results show that thermal resistance is decreased as the height of heat sink increases and the fin height and fin pitch decrease, From the experimental data of layered type heat sink, the correlation equation of Nusselt number was obtained as follows ; $$Nu=0.845{\cdot}Re^{0.393}{\cdot}(\frac{f_h}{D_h})^{0.160}{\cdot}(\frac{f_p}{D_h})^{0.372}{\cdot}(\frac{H_{hs}}{D_h})^{-0.942}$$

  • PDF

히트파이프 응축부의 초음파 분무냉각에 관한 실험적 연구 (An Experimental Study on Ultrasonic Spray Cooling of Heat Pipe Condenser)

  • 김영찬;한양호
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.77-83
    • /
    • 2004
  • In this study, the spray cooling heat transfer and working characteristics of the screen wick heat pipe with ultrasonic spray cooling system in condenser were experimentally investigated. The heat pipe was made of copper tube 300 mm long with inner diameter of 11.1 mm. The evaporator and condenser lengths of heat pipe were 40, 200 mm and the wick structure consists of two layer of 100 mesh copper screen. The experimental results show that the ultrasonic spray cooling increases the heat transfer rate on the condenser surface, and the total thermal resistance of heat pipe system decreases remarkably. A comparison is made for the two working fluids, water and ethanol. The surface temperature of the ethanol tube in evaporator section becomes higher than that of the water tube. Thus, the experimental result shows that water is more useful than ethanol as the working fluid because of increasing the operational limit within this experimental conditions.

엔탈피법을 이용한 원통형 몰드내에서의 상변화과정에 관한 연구 (A study on the phase change in the cylindrical mold by the enthalpy method)

  • 여문수;최상경;김문철
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.891-897
    • /
    • 1999
  • The heat transfer characteristics at the interface between the mold and the casting is one of the major factors for the solidification speed which determines the casting structures. The thermal resistance exists due to air gap formation at the mold/casting interface during the freezing process. In this study one dimensional Stefan problem with the air-gap resistance in the cylindrical mold is considered and the heat transfer characteristics is numerically examined by using the enthalpy method which is convenient in solving the Stefan problem with mushy zone. The present results agreed very well with those of previous papers. The effects of major parameters such as thermal conductivity, heat transfer coefficient of mold, on the thermal characteristics are investigated.

  • PDF

환상 열파이프의 열전달특성 연구 (Performance of an Annular Heat Pipe)

  • 송태호;이정오
    • 대한설비공학회지:설비저널
    • /
    • 제8권1호
    • /
    • pp.1-9
    • /
    • 1979
  • Heat transfer characteristics of an annular heat pipe is investigated theoretically and experimentally. An annular heat pipe transports maximum heat which is found to be a cubic polynomial function of the thickness of annulus when the annulus becomes large, maximum heat transfer rate Is limited by boiling criterion. The limit decreases inversely proportional to the thickuess of annulus. Theoretical formula for thermal resistance of annular heat pipe Is proposed. Experimental results on the maximum heat transfer rate satisfactorily agree with theory. Measured thermal resistance is found to be lower than the predicted results as the thickness of annulus becomes large.

  • PDF

열교환 부품용 발열체 형성기술 (The Formation Technique of Thin Film Heaters for Heat Transfer Components)

  • 조남인;김민철
    • 반도체디스플레이기술학회지
    • /
    • 제2권4호
    • /
    • pp.31-35
    • /
    • 2003
  • We present a formation technique of thin film heater for heat transfer components. Thin film structures of Cr-Si have been prepared on top of alumina substrates by magnetron sputtering. More samples of Mo thin films were prepared on silicon oxide and silicon nitride substrates by electron beam evaporation technology. The electrical properties of the thin film structures were measured up to the temperature of $500^{\circ}C$. The thickness of the thin films was ranged to about 1 um, and a post annealing up to $900^{\circ}C$ was carried out to achieve more reliable film structures. In measurements of temperature coefficient of resistance (TCR), chrome-rich films show the metallic properties; whereas silicon-rich films do the semiconductor properties. Optimal composition between Cr and Si was obtained as 1 : 2, and there is 20% change or less of surface resistance from room temperature to $500^{\circ}C$. Scanning electron microscopy (SEM) and Auger electron spectroscopy (AES) were used for the material analysis of the thin films.

  • PDF

가금 유래 병원성 대장균의 항균제 내성 및 R plasmid 전달 양상 (Antimicrobial resistance and transfer of R plasmid of pathogenic Eseherichia coli isolated from poultry in Korea)

  • 성명숙;김진현;조재근;설성용;김기석
    • 대한수의학회지
    • /
    • 제48권3호
    • /
    • pp.275-285
    • /
    • 2008
  • Antimicrobial drugs are widely used in poultry industry as growth promoters or to control infectious diseases. However, this practice is reported to have caused high resistance to antimicrobial drugs in normal chicken flora and pathogens. Antimicrobial resistance to Escherichia coli (E. coli) from chicken has been mainly reported in normal flora, but rare in pathogenic organism in Korea, recently. Therefore, this study was conducted to investigate prevalence of antimicrobials resistance, transfer of R plasmid, and association between antimicrobial drug resistance and O serotype of 203 pathogenic E. coli from poultry in Korea during the period from April 2003 to December 2005. These isolates showed a high resistance to tetracycline (Tc, 93.6%), nalidixic acid (Na, 92.6%), streptomycin (Sm, 81.8%), ampicillin (Ap, 77.3%), ciprofloxacin (Ci, 70.9%), sulfisoxazole (Su, 66.5%), and trimethoprim (Tp, 58.1%). Two hundred-one (99.0%) of the isolates were resistant to one or more drugs. They showed 57 different resistant patterns, and the most prevalent resistant pattern among them was Tc, Sin, Su, Ap, Tp, Ci, Na. Sixty-eight (33.8%) of the isolates transferred all or a part of their antimicrobial resistant pattern to the recipient strain by R plasmid. The most common antimicrobial resistant pattern was Tc, Sm, Su, Ap, Tp, Ci, Na in serotype O78, O88 and O15, respectively. These results exhibit high individual and multiple resistance to antimicrobials of pathogenic E. coli from poultry in Korea. They also suggest the needs for surveillance to monitor antimicrobial resistance in pathogenic bacteria that can be potentially transmitted to humans from food animals and to regulate the abuse of antimicrobials on food-producing animals in Korea.

Ansys를 활용한 플랜트 시설물 내화성능에 대한 해석적 연구 (Analytical Study of Fire Resistance Performance of Plant Facilities using Ansys)

  • 최두찬;양민혁;오수민;양소진
    • 한국재난정보학회 논문집
    • /
    • 제19권4호
    • /
    • pp.958-967
    • /
    • 2023
  • 연구목적: 본 연구는 화재위험도가 높은 플랜트 시설물에 적용하고 있는 국내 내화성능을 분석하고 적합한 내화저항성능을 확보하여 플랜트 시설물의 화재 안전성을 확보하고자 한다. 연구방법:유한요소해석 프로그램인 Ansys를 활용하여 화재하중과 내화피복을 변수로 열전달 해석과 구조해석을 수행하고 해석 결과에 따른 플랜트 시설물의 내화성능을 분석하였다. 연구결과: 국내 플랜트 시설물에 적용된 내화피복은 UL 1709에 제시된 탄화수소화재의 화재하중을 적용하였을 때 내화성능을 확보하지 못하였으며 화재 후 강재의 변형 또한 크게 나타남을 확인하였다. 결론:현재 플랜트 시설물에 적용된 국내의 내화성능은 석유화학 플랜트 등과 같이 급격한 화재성장과 큰 화재하중에서 내화성능을 확보할 수 없으며 플랜트 시설물의 성능평가를 통해 적합한 내화성능을 평가하여 화재 안전성을 확보하여야 한다.

A60급 갑판 관통 관의 방화성능 평가를 위한 과도 열전달 해석과 화재시험 (Transient Heat Transfer Analysis and Fire Test for Evaluation on Fire Resistance Performance of A60 Class Deck Penetration Piece)

  • 박우창;송창용
    • 한국산학기술학회논문지
    • /
    • 제22권4호
    • /
    • pp.1-9
    • /
    • 2021
  • A60급 갑판 관통 관은 선박과 해양플랜트의 화재 발생 시 인명의 보호와 화염전파를 방지하기 위해 갑판 구획에 설치되는 방화 장치이다. A60급 갑판 관통 관이 새로 개발되거나 기존의 설계가 변경될 경우 국제해사기구의 화재시험절차 규정에 따라 A60급 갑판 관통 관의 방화성능을 검증하도록 요구하고 있다. 따라서, 본 논문에서는 신규 개발된 선박과 해양플랜트용 A60급 갑판 관통 관의 방화 설계의 적합성을 평가하기 위해 과도 열전달 해석을 수행하였고, 화재시험을 통해 해석결과의 타당성을 검증하였다. 또한 A60급 갑판 관통 관의 열전달 특성은 관의 직경, 내부형상 그리고 재질과 같은 설계 사양에 따라 비교하여 검토하였다. 과도 열전달 해석은 범용 유한요소법 소프트웨어인 ABAQUS/Implicit를 사용하여 수행하였으며, 해석결과의 검증을 위한 화재시험은 해사안전위원회에서 규정한 화재시험절차 코드에 따라 수행하였다. 본 연구에서 검토한 A60급 갑판 관통 관의 방화성능은 국제 해상안전규정을 만족하였고, 재질 사양의 설계가 중요한 것으로 나타났다. 최대 시험온도를 기준으로 SUS316L 재질의 측정온도는 S45C 재질보다 평균적으로 25% 낮게 나타났고, 이때 각 재질의 열전도계수와 비열의 차이는 각각 17%와 58%였다.

양방향 말뚝선단재하시험에 의한 암반근입 현장타설말뚝의 하중-침하거동 분석 (Load-Settlement Behavior of Rock-socketed Drilled Shafts by Bi-directional Pile Load Test)

  • 설훈일;정상섬;한근택;김재영
    • 한국지반공학회논문집
    • /
    • 제24권11호
    • /
    • pp.61-70
    • /
    • 2008
  • 본 연구에서는 국내 4개 지역에서 시공된 총 10본의 대구경 암반 근입 현장타설말뚝의 양방향 말뚝 선단재하시험과 일반적인 말뚝두부 재하시험을 토대로 하중 재하방식에 따른 말뚝의 침하거동 및 하중전이 거동 특성을 분석하였다. 이로부터 양방향 재하하중을 받는 현장타설말뚝의 등가 말뚝 두부하중침하 거동을 고찰하곤 기존 등가 두부하중침하 곡선 산정방법과의 비교분석을 통하여 주면하중에 의해 추가적인 선단침하량의 영향정도를 분석하였다. 본 연구결과, 주면하중에 의해 발생되는 선단침하량을 고려한 하중전이해석(coupled load transfer analysis)을 통한 하중-침하량 예측값은 정재하 시험결과를 적절히 예측하는 것으로 나타났으나, 근사적 해석법을 통한 등가 하중-침하 곡선 및 일반적인 하중전이해식(uncoupled load transfer analysis)의 예측값은 정재하 시험결과에 비해 침하량을 과소 평가할 수 있음을 알 수 있었다. 하지만, 시험말뚝 근입부분의 암반층이 매우 단단할 경우 주면하중에 의한 선단침하량이 매우 작은 것으로 나타났다.

마이크로휜 관내의 단상유동 열전달계수 (Heat transfer coefficients for single-Phase flow in a micro-fin tube)

  • 권정태;김무환
    • 설비공학논문집
    • /
    • 제10권4호
    • /
    • pp.423-430
    • /
    • 1998
  • Single phase heat transfer coefficients were measured for turbulent water flow in a micro-fin tube by using Wilson plot technique. An experiment for counterflow heat exchange between the micro-fin tube and its outer annulus passage was performed. The annulus side heat transfer resistance was varied and the overall heat transfer coefficients were measured. The single-phase heat transfer coefficients in a micro-fin tube were obtained by Wilson plot technique. Nusselt numbers based on the real heat transfer area and the nominal area were about 35% and 50% larger than those for smooth tube respectively Also, single-phase heat transfer correlations based on real heat transfer area and nominal area have been proposed for a micro-fin tube.

  • PDF