• 제목/요약/키워드: Transfer integral

검색결과 232건 처리시간 0.025초

기능성 편광필름을 이용한 2차원/3차원 전환가능 변형 집적 영상 시스템 (Two-dimensional / Three-dimensional convertible modified integral imaging system using functional polarizing film)

  • 송병섭;박순기;민성욱
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2009년도 창립 20주년기념 특별학술발표회
    • /
    • pp.6-7
    • /
    • 2009
  • We proposed the two-dimensional (2D) / three-dimensional (3D) convertible modified integral imaging system using functional polarizing film named $imazer^{TM}$, which transfer or scatter the incident light ray according to the polarizing direction of ray. When the incident light rays transfer to $imazer^{TM}$, the rays generate 3D image through the process of the modified integral imaging system. However, the scattered light rays generate 2D image through the simple backlight scheme when the incident rays are scattered by the film. The proposed method can be implemented the partial 3D display system without any mechanical movements. In this paper, we propose and verify our system using some basic experiments and its results.

  • PDF

낮은 핀 관의 응축 열전달 성능에 관한 연구 (A Study on the Condensation Heat Transfer of Low Integral Fin Tubes)

  • 한규일;박성국
    • 수산해양기술연구
    • /
    • 제32권1호
    • /
    • pp.67-77
    • /
    • 1996
  • The heat transfer performance of R - 11 vapor condensing on integral fin tubes has been studied using fin tubes having the fin density from 748 to 1654 fins per meter. Electric heater supplied heat energy to the boiler to generate R - 11 vapor over the range of 25-60W. Condensation rates of each tubes were tested under the condition of cooling water flow rate from 400l/h to 2500l/h. For the seven fin tubes tested, the best performance has been obtained with a tube having a fin density of 1417fpm and a fin height of 1.3mm. This tube has yielded a maximum value of the heat transfer coefficient of 16500W/$m_2$K, at a vapor to wall temperature difference of 3K. Experimental results of integral fin tubes have been compared with available predictive models such as Beatty - Katz's analysis, Webb's analysis, Sukhatme's analysis and Rudy's empirical relation. The experimental results were shown to be in good agreement with that of the Sukhatme's analysis.

  • PDF

ON THE q-EXTENSION OF THE HARDY-LITTLEWOOD-TYPE MAXIMAL OPERATOR RELATED TO q-VOLKENBORN INTEGRAL IN THE p-ADIC INTEGER RING

  • Jang, Lee-Chae
    • 충청수학회지
    • /
    • 제23권2호
    • /
    • pp.207-213
    • /
    • 2010
  • In this paper, we define the q-extension of the Hardy-Littlewood-type maximal operator related to q-Volkenborn integral. By the meaning of the extension of q-Volkenborn integral, we obtain the boundedness of the q-extension of the Hardy-Littlewood-type maximal operator in the p-adic integer ring.

Integral effect test for steam line break with coupling reactor coolant system and containment using ATLAS-CUBE facility

  • Bae, Byoung-Uhn;Lee, Jae Bong;Park, Yu-Sun;Kim, Jongrok;Kang, Kyoung-Ho
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2477-2487
    • /
    • 2021
  • To improve safety analysis technology for a nuclear reactor containment considering an interaction between a reactor coolant system (RCS) and containment, this study aims at an experimental investigation on the integrated simulation of the RCS and containment, with an integral effect test facility, ATLAS-CUBE. For a realistic simulation of a pressure and temperature (P/T) transient, the containment simulation vessel was designed to preserve a volumetric scale equivalently to the RCS volume scale of ATLAS. Three test cases for a steam line break (SLB) transient were conducted with variation of the initial condition of the passive heat sink or the steam flow direction. The test results indicated a stratified behavior of the steam-gas mixture in the containment following a high-temperature steam injection in prior to the spray injection. The test case with a reduced heat transfer on the passive heat sink showed a faster increase of the P/T inside the containment. The effect of the steam flow direction was also investigated with respect to a multi-dimensional distribution of the local heat transfer on the passive heat sink. The integral effect test data obtained in this study will contribute to validating the evaluation methodology for mass and energy (M/E) and P/T transient of the containment.

Impact of bonding defect on the tensile response of a composite patch-repaired structure: Effect of the defect position and size

  • N., Kaddouri;K., Madani;S.CH., Djebbar;M., Belhouari;R.D.S.G., Campliho
    • Structural Engineering and Mechanics
    • /
    • 제84권6호
    • /
    • pp.799-811
    • /
    • 2022
  • Adhesive bonding has seen rapid development in recent years, with emphasis to composite patch repairing processes of geometric defects in aeronautical structures. However, its use is still limited given its low resistance to climatic conditions and requirement of specialized labor to avoid fabrication induced defects, such as air bubbles, cracks, and cavities. This work aims to numerically analyze, by the finite element method, the failure behavior of a damaged plate, in the form of a bonding defect, and repaired by an adhesively bonded composite patch. The position and size of the defect were studied. The results of the numerical analysis clearly showed that the position of the defect in the adhesive layer has a large effect on the value of J-Integral. The reduction in the value of J-Integral is also related to the composite stacking sequence which, according to the mechanical properties of the ply, provides better load transfer from the plate to the repair piece through the adhesive. In addition, the increase in the applied load significantly affects the value of the J-Integral at the crack tip in the presence of a bonding defect, even for small dimensions, by reducing the load transfer.

Axisymmetric analysis of multi-layered transversely isotropic elastic media with general interlayer and support conditions

  • Lee, J.S.;Jiang, L.Z.
    • Structural Engineering and Mechanics
    • /
    • 제2권1호
    • /
    • pp.49-62
    • /
    • 1994
  • Based on the transfer matrix approach and integral transforms, a solution method is developed for the stress analysis of axisymmetrically loaded transversely isotropic elastic media with generalized interlayer and support conditions. Transfer functions (Green's functions in the transformed domain) are obtained in explicit integral form. For several problems of practical interest with different loading and support conditions, solutions are worked out in detail. For the inversion operation, an efficient technique is introduced to remedy the slow convergence of numerical integrals involving oscillating functions. Several illustrative examples are considered and numerical results are presented.

수치해석 통합기법을 이용한 노즐 내열재 표면의 열전달 해석 (Heat Transfer on Supersonic Nozzle using Combined Boundary Layer Integral Method)

  • 배지열;배형모;류진;함희철;조형희
    • 한국전산구조공학회논문집
    • /
    • 제30권1호
    • /
    • pp.47-53
    • /
    • 2017
  • 1차원 등엔트로피 모델과 통합된 경계층 적분법은 초음속 노즐의 설계과정에서 내열재 표면의 열전달을 예측하는데 효과적으로 사용되고 있지만 노즐 목과 같이 2차원 효과와 경계층과 노즐 코어유동의 상호작용이 발생하는 지점에서는 경계층 외부유동 해석의 부정확성으로 해석의 정확도가 감소한다. 따라서 본 연구에서는 경계층 적분법을 이용한 열전달 예측의 정확도를 향상시키기 위해 CFD를 이용하여 2차원 효과와 노즐 코어유동의 상호작용이 고려된 경계층 외부유동 조건을 도출하고 이를 경계조건으로 하는 해석기법을 개발하였다. 오일러 모델과 SST $k-{\omega}$ 모델을 CFD로 해석하여 경계조건으로 적용했으며 계산방법을 검증하기 위해 선행문헌의 실험노즐에 대해 해석을 수행하였다. 계산 결과 CFD를 통해 경계층 외부유동 조건을 도출한 해석에서 노즐 열전달의 정확도가 향상되는 것을 확인하였으며 특히 노즐 목 후방과 팽창부에서의 차이가 크게 나타났다. SST $k-{\omega}$모델로 도출된 계산결과는 1차원 등엔트로피 모델과 비교 시 팽창부에서 실험결과와의 오차가 16% 감소하였다. 본 연구에서 개발된 해석기법은 향후 로켓노즐의 내열설계에 유용하게 사용될 것으로 평가된다.

Integral Analysis of the Effects of Non-absorbable gases on the Heat Mass Transfer of Laminar Falling Film

  • Kim, Byong-Joo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.56-66
    • /
    • 1998
  • The absorption process of water vapor in a liquid film is an important process in LiBr-Water absorption system. The composition of the gas phase, in which a non-absorbable gas is combined with the absorbate, influences the transport characteristics. In the present work, the absorption processes of water vapor into aqueous solutions of lithium bromide in the presence of non-absorbable gas are investigated. The continuity, momentum, energy and diffusion equations for the solution film and gas are formulated in integral forms and solved numerically. It is found that the mass transfer resistance in gas phase increases with the concentration of non-absorbable gas. However the primary resistance to mass transfer is in the liquid phase. As the concentration of non-absorbable gas in the absorbate increases, the interfacial temperature and concentration of absorbate in solution decrease, which results in the reduction of absorption rate. The reduction of mass transfer rate is found to be significant for the addition of a small amount of non-absorbable gas to the pure vapor, especially at the outlet of tube where the non-absorbable gas accumulates. At higher non-absorbable gas concentration, the decrease of absorption rate seems to be linear to the concentration of non-absorbable gas.

  • PDF

SEPARATE AND INTEGRAL EFFECT TESTS FOR VALIDATION OF COOLING AND OPERATIONAL PERFORMANCE OF THE APR+ PASSIVE AUXILIARY FEEDWATER SYSTEM

  • Kang, Kyoung-Ho;Kim, Seok;Bae, Byoung-Uhn;Cho, Yun-Je;Park, Yu-Sun;Yun, Byoung-Jo
    • Nuclear Engineering and Technology
    • /
    • 제44권6호
    • /
    • pp.597-610
    • /
    • 2012
  • The passive auxiliary feedwater system (PAFS) is one of the advanced safety features adopted in the APR+, which is intended to completely replace the conventional active auxiliary feedwater system. With an aim of validating the cooling and operational performance of PAFS, an experimental program is in progress at KAERI, which is composed of two kinds of tests; the separate effect test and the integral effect test. The separate effect test, PASCAL ($\underline{P}$AF$\underline{S}$ $\underline{C}$ondensing Heat Removal $\underline{A}$ssessment $\underline{L}$oop), is being performed to experimentally investigate the condensation heat transfer and natural convection phenomena in PAFS. A single, nearly-horizontal U-tube, whose dimensions are the same as the prototypic U-tube of the APR+ PAFS, is simulated in the PASCAL test. The PASCAL experimental result showed that the present design of PAFS satisfied the heat removal requirement for cooling down the reactor core during the anticipated accident transients. The integral effect test is in progress to confirm the operational performance of PAFS, coupled with the reactor coolant systems using the ATLAS facility. As the first integral effect test, an FLB (feedwater line break) accident was simulated for the APR+. From the integral effect test result, it could be concluded that the APR+ has the capability of coping with the hypothetical FLB accident by adopting PAFS and proper set-points of its operation.

A Study on Integral Equalities Related to a Laplace Transformable Function and its Applications

  • Kwon, Byung-Moon;Ryu, Hee-Seob;Kwon, Oh-Kyu
    • International Journal of Control, Automation, and Systems
    • /
    • 제1권1호
    • /
    • pp.76-82
    • /
    • 2003
  • This paper establishes some integral equalities formulated by zeros located in the convergence region of a Laplace transformable function. Using the definition of the Laplace transform, it shows that Laplace transformable functions have to satisfy the integral equalities in the time-domain, which can be applied to the understanding of the fundamental limitations on the control system represented by the transfer function. In the unity-feedback control scheme, another integral equality is derived on the output response of the system with open-loop poles located in the convergence region of the output function. From these integral equalities, two sufficient conditions related to undershoot and overshoot phenomena in the step response, respectively, are investigated.