• 제목/요약/키워드: Transfer film

검색결과 1,073건 처리시간 0.029초

극박형 복합재료 필름의 표면 물성 분석에 대한 연구 (Analysis of Surface Characteristics for Clad Thin Film Materials)

  • 이준하
    • 반도체디스플레이기술학회지
    • /
    • 제17권1호
    • /
    • pp.62-65
    • /
    • 2018
  • In the era of the 4th Industrial Revolution, IoT products of various and specialized fields are being developed and produced. Especially, the generation of the artificial intelligence, robotic technology Multilayer substrates and packaging technologies in the notebook, mobile device, display and semiconductor component industries are demanding the need for flexible materials along with miniaturization and thinning. To do this, this work use FCCL (Flexible Copper Clad Laminate), which is a flexible printed circuit board (PCB), to implement FPCB (Flexible PCB), COF (Chip on Film) Use is known to be essential. In this paper, I propose a transfer device which prevents the occurrence of scratches by analyzing the mechanism of wrinkle and scratch mechanism during the transfer process of thin film material in which the thickness increases while continuously moving in air or solution.

액적의 리바운드 모션에 주목한 분무냉각 막비등 열전달 모델 (Film Boiling Heat Transfer Model of Spray Cooling Focusing on Rebound Motion of Droplets)

  • 김영찬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1317-1322
    • /
    • 2004
  • In this report, the heat transfer model of spray cooling on hot surface was developed by focusing on the effect of rebound motion of droplets. In the model, it was assumed that droplets rebound repeatedly on the hot surface and heat transfer upon droplet impact is proportional to sensible heat which heats up the droplets to the saturation temperature. In addition, to take account of the contribution of th heat flux upon impact of rebound droplets, it was assumed that the rebound droplets are distributed following the Gaussian distribution from 0 to L, which distance L is determined by maximum flight distance $L_{max}$. Also the calculated results were compared with existing experimental results.

  • PDF

전달함수를 이용한 유정압테이블 운동정밀도 해석법의 실험적 검증 (Experimental Verification on Motion Error Analysis Method of Hydrostatic Tables Using Transfer Function)

  • 오윤진;박천홍;이찬홍;홍준희
    • 한국정밀공학회지
    • /
    • 제19권5호
    • /
    • pp.64-71
    • /
    • 2002
  • A new model utilizing a transfer function was proposed in the previous paper fur analizing motion errors of hydrostatic tables. Validity of the proposed method was theoretically verified as the calculated motion errors were compared with the results by conventional multi pad method. In this paper, relationship between form error of rail and motion errors of hydrostatic table is analized theoretically in order to comprehand so-called ‘averaging effect of oil film’. Experiments on the motion errors of hydrostatic table is conducted with 3 different rails, and the results are compared with the results calculated by Transfer Function Method. The results show good agreement. From the results, it is verified that TFM is very effective to analize the motion errors of hydrostatic table.

PCCS Analysis Model for the Passively Cooled Steel Containment

  • Hwang, Y.D.;Chung, B.D.;Cho, B.H.;Chang, M.H.;Jeong, Ik
    • Nuclear Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.26-39
    • /
    • 1998
  • The containment pressure and temperature transient analysis computer code CONTEMPT4/MOD5 is modified to incorporate the passive containment cooling models. The correlations are selected from the existing experimental heat transfer correlations to model the natural and mixed convection in annular space between the containment shell and the shield building. The evaporative heat transfer of the water film on the outer shell of the containment is modeled using the correlations derived from the analogy between the heat and mass transfer. The modified code is applied to the Ap600 containment transient analysis for the model verification and the results are compared to the results of GOTHIC calculation done by Westinghouse. Also, d series of parametric sensitivity studies of heat transfer correlations, water film ratio and delay time of the wet cooling on the containment peak pressure and temperature following LOCA are performed for the containment of 1000MWe passive plant, KP1000.

  • PDF

전달함수를 이용한 유정압테이블 운동정밀도 해석법의 실험적 검증 (Experimental Verification on Motion Error Analysis Method of Hydrostatic Tables Using Transfer Function)

  • 박천흥;오윤진;이후상;홍준희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.454-458
    • /
    • 2001
  • A new model utilizing a transfer function was proposed in the previous paper for analizing motion errors of hydrostatic tables. Validity of the proposed method was theoretically verified as the calculated motion errors were compared with the results by conventional multi pad method. In this paper, relationship between form error of rail and motion errors of hydrostatic table is analized theoretically in order to comprehand so-called 'averaging effect of oil film'. Experiments on the motion errors of hydrostatic table is conducted with 3 different rails, and the results are compared with the results calculated by Transfer Function Method. The results show good agreement. From the results, it is verified that TFM is very effective to analize the motion errors of hydrostatic table.

  • PDF

수직형 흡수기 성능에 미치는 흡수기 전열관의 직경과 길이의 영향 (Effect of Diameter and Length on the Absorption Performance in a Vertical Absorber Tube)

  • 서정훈;조금남
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1214-1222
    • /
    • 2001
  • The present study investigated the effect of diameter and length on the absorption performance of a vertical falling film type absorber using $LiBr-H_2$O solution of 60 wt%. The parameters were diameter of absorber (17.2, 23.4, 31.1 mm), length of absorber (771, 1150, 1528 mm), and film Reynolds numbers (50, 70, 90, 110, 130, 150). As the diameter of the absorber was increased, the absorption mass flux, Sherwood number, heat flux, and heat transfer coefficient were increased, in which Sherwood number and heat transfer coefficient were increased up to 13% and 30% respectively. As the length of the absorber was increased, the total absorption rate and heat transfer coefficient were increased by 37% and 35% respectively, while the absorption mass flux was decreased.

  • PDF

전기가열식 필름 천공기의 열전달률 개선 (An Improvment of Heat Transfer of Electric Hole Cutter for Polyethylen Film)

  • 김종일;김재홍
    • 한국안전학회지
    • /
    • 제15권1호
    • /
    • pp.66-71
    • /
    • 2000
  • This paper presents a development of an electric hole cutter for agricultural polyethylen film. Mechanical hole cutter with blades and electrical hole cutters are being tried in products now. But Mechanical hole cutter systems have a few faults. So the hole cutter systems using electrical heater have mainly been developed and optimized. Computer aided engineering was introduced for the purpose of electric heated hole cutter being developed, because it helped reduce the unnecessary tests. Three types of heated cups were surveyed with MSC/Nastran, and the type of model C was most effective in heat transfer.

  • PDF

CT 검사에서 시간분석에 의한 필름시스템과 PACS의 비교 연구 (Comparison of Time Analysis on the Film Based System Versus PACS in the CT Scanning)

  • 권대철;홍성만;박범
    • 산업공학
    • /
    • 제15권4호
    • /
    • pp.439-443
    • /
    • 2002
  • In this paper, we study to evaluate the relative time required to perform the CT scanning in the PACS versus a film-based system and helical versus non-helical studies. Time studies were performed in 175 consecutive CT scanning. Images from 85 examinations were electronically transferred to a PACS, and 90 were printed to film. The time required to obtain and electronically transfer the images or print the images to film and make the current and previous studies available to the radiologists for interpretation was recorded. The time required for a radiological technologist to complete a CT test was reduced by 43% with the PACS compared with the film-based system and nonhelical was reduced 10~20% with helical studies. This reduction was due to the elimination of a transfer and printing, such as the printing at window or level settings. The use of PACS can result in the elimination of time tasks for the radiological technologist, resulting in marked reduction in examination time. This reduction can result in decreased cost and increased productivity in PACS operation.