• 제목/요약/키워드: Transfer device

검색결과 1,129건 처리시간 0.023초

Heat Dissipation of Sealed LED Light Fixtures Using Pulsating Heat Pipe Technology

  • Kim, Hyung-Tak;Park, Hae-Kyun;Bang, Kwang-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권1호
    • /
    • pp.64-71
    • /
    • 2012
  • An efficient cooling system is an essential part of the electronic packaging such as a high-luminance LED lighting. A special technology, Pulsating Heat Pipe (PHP), can be applied to improve cooling of a sealed, explosion-proof LED light fixture. In this paper, the characteristics of the pulsating heat pipes in the imposed thermal boundary conditions of LED lightings were experimentally investigated and a PHP device that works free of alignment angle was investigated for cooling of explosion-proof LED lights. Five working fluids of ethanol, FC-72, R-123, water, and acetone were chosen for comparison. The experimental pulsating heat pipe was made of copper tubes of internal diameter of 2.1 mm, 26 turns. A variable heat source of electric heater and an array of cooling fins were attached to the pulsating heat pipe. For the alignment of the heating part at bottom, an optimum charging ratio (liquid fluid volume to total volume) was about 50% for most of the fluids and water showed the highest heat transfer performance. For the alignment of the heating part on top, however, only R-123 worked in an un-looped construction. This unique advantage of R-123 is attributed to its high vapor pressure gradient. Applying these findings, a cooling device for an explosion-proof type of LED light rated 30 W was constructed and tested successfully.

ISO/IEEE 11073 개인건강기기 표준의 PM-store 구현을 위한 복잡도 분석 (Complexity Analysis for Implementation of the PM-store of ISO/IEEE 11073 PHD Standards)

  • 김상곤;이창기;김태곤;황희정
    • 전기전자학회논문지
    • /
    • 제19권3호
    • /
    • pp.447-454
    • /
    • 2015
  • 본 논문은 ISO/IEEE 11073 개인건강기기 표준에서 정의된 PM-store 개념을 적용하여 주기적으로 발생하는 대용량 측정 데이터의 전송 프로토콜을 구현할 경우, 개인건강기기의 중앙처리장치(CPU)에서 수행해야 하는 명령사이클(instruction cycles)의 수를 기반으로 한 복잡도 분석에 대한 연구이다. PM-store의 구성에 따라 중앙처리 장치가 처리해야 할 명령 사이클의 수에 대한 분석모델을 제시하였다.

Evaluation Methods and Design for Bioartificial Liver Based on Perfusion Model

  • Park Yueng Guen;Ryu Hwa-Won
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제10권1호
    • /
    • pp.9-15
    • /
    • 2005
  • A bioartificial liver (BAL) is a medical device entrapping living hepatocytes or immortalized cells derived from hepatocytes. Many efforts have already been made to maintain the functions of the hepatocytes in a BAL device over a long term. However, there is still some uncertainty as to their efficacy. and their limitations are unclear. Therefore, it is important to quantitatively evaluate the metabolic functions of a BAL. In previous studies on in vitro BAL devices, two test methods, an initial bolus loading and constant-rate infusion plus initial bolus loading, were theoretically carried out to obtain physiologic data on drugs. However, in the current study, the same two methods were used as a perfusion model and derived the same clearance characterized by an interrelationship between the perfusate flow rate and intrinsic clearance. The interrelationship indicated that the CL increased with an increasing perfusate flow rate and approached its maximum value, i.e. intrinsic clearance. In addition, to set up an in vivo BAL system, the toxic plateau levels in the BAL system were calculated for both series and parallel circuit models. The series model had a lower plateau level than the parellel model. The difference in the toxic plateau levels between the parallel and series models increased with an increasing number of BAL cartridges.

정상상태에서 카뷰레터 더미모델의 스로틀 개도에 따른 압력특성 (The characteristics of suction pressure by throttle opening of the carburetor dummy at steady state)

  • 조형문;김병국;최영하;윤석주;한종규
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.711-714
    • /
    • 2008
  • The objective of this paper is to know the characteristics of pressure through a simplified typical carburetor used in small engines at the different throttle opening conditions. The carburetor is the device responsible for creating the right air-fuel mixture according to the different engine operating conditions. It is activated by the static or the dynamic pressure. The carburetor dummy is geometrically similar of LPG brush-cutter engine's diaphragm carburetor and is made of acrylic. Suction system gives body to crankcase vacuum using the vacuum pump and throttle opening conditions are controled by transfer device. Carburetor venturi throat and fuel charging tube diameter is each 20mm, 4.1mm. The result of the work presents an unprecedented phenomenon of suction pressure variation inside the carburetor venturi. It is predicted that these unprecedented pressure variation be caused by minor losses; sudden contraction or expansion, open or partially closed and so on.

  • PDF

Facile fabrication of ZnO Nanostructure Network Transistor by printing method

  • Choi, Ji-Hyuk;Moon, Kyeong-Ju;Jeon, Joo-Hee;Kar, Jyoti Prakash;Das, Sachindra Nath;Khang, Dahl-Young;Lee, Tae-Il;Myoung, Jae-Min
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2010년도 춘계학술발표대회
    • /
    • pp.31.1-31.1
    • /
    • 2010
  • Various ZnO nanostructures were synthesized and ZnO nanostructure-based self-assembled transistors were fabricated. Compared to spindle and flower like nanostructure, the ZnO nanorod (NR) structure showed much stronger gate controllability, and greatly enhanced device performance, demonstrating that this structural variation leads to significant differences of the nanostructure network-based device performance. Also, patterned dry transfer-printing technique that can generate monolayer-like percolating networks of ZnO NRs has been developed. The method exploits the contact area difference between NR-NR and NR-substrate, rather than elaborate tailoring of surface chemistry or energetic. The devices prepared by the transferring method exhibited on/off current ratio, and mobility of ${\sim}2.7{\times}10^4$ and ${\sim}1.03\;cm^2/V{\cdot}s$, respectively. Also, they exhibited showing lower off-current and stronger gate controllability due to defined-channel between electrodes and monolayer-like network channel configuration. With multilayer stacks of nanostructures on stamp, the monolayer-like printing can be repeated many times, possibly on large area substrate, due to self-regulating printing characteristics. The method may enable high-performance macroelectronics with materials that have high aspect ratio.

  • PDF

금속-킬레이트계($Snq_2,Snq_4$) 발광층을 이용한 유기 전기 발광 소자의 제작과 전기.광학적 특성 (Fabrication of Organic Electroluminescent Device and electro-optical properties using metal-chelates($Snq_2,Snq_4$) for Emitting Material Layer)

  • 윤희찬;유정현;김병상;김정균;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1575-1577
    • /
    • 2002
  • In this study, multi layer type OLED(Organic Light Emitting Diode) has been fabricated using $Snq_2$, $Snq_4$, and $Alq_3$ for development of high efficiency, electrical and optical properties of multi layer type OLED investigated. The HTL(Hole Transfer Layer) and EML(Emitting Material Layer) were fabricated by using vacuum evaporation on ITO electrode, and its thickness controlled using thickness monitor. Al was used as a cathode. The electrical and optical properties such as J-V, brightness-V and EL spectrum of OLED device was measured using I.V.L.T system. The result, brightness of $Alq_3$, $Snq_2$ and $Snq_4$ were $3900cd/m^2$, $63cd/m^2$ and $23cd/m^2$ respectively.

  • PDF

In-Situ Heat Cooling using Thick Graphene and Temperature Monitoring with Single Mask Process

  • Kwack, Kyuhyun;Chun, Kukjin
    • 센서학회지
    • /
    • 제24권3호
    • /
    • pp.155-158
    • /
    • 2015
  • In this paper, in-situ heat cooling with temperature monitoring is reported to solve thermal issues in electric vehicle (EV) batteries. The device consists of a thick graphene cooler on top of the substrate and a platinum-based resistive temperature sensor with an embedded heater above the graphene. The graphene layer is synthesized by using chemical vapor deposition directly on the Ni layer above the Si substrate. The proposed thick graphene heat cooler does not use transfer technology, which involves many process steps and does not provide a high yield. This method also reduces the mechanical damage of the graphene and uses only one photomask. Using this structure, temperature detection and cooling are conducted simultaneously using one device. The temperature coefficient of resistance (TCR) of a $1{\times}1mm^2$ temperature sensor on 1-$\grave{i}m$-thick graphene is $1.573{\times}10^3ppm/^{\circ}C$. The heat source cools down $7.3^{\circ}C$ from $54.4^{\circ}C$ to $47.1^{\circ}C$.

Ir$(ppy)_3$를 발광물질로 이용한 EL소자의 특성분석 (The characteristics of the electroluminescent devices using Ir$(ppy)_3$)

  • 김준호;김윤명;하윤경;김영관;김정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.437-439
    • /
    • 2000
  • The internal quantum efficiency of EL devices using fluorescent organic materials is limited within 25% because of the triplet excitons which can hardly emit light. So there has been considerable interest in finding ways to obtain light emission from triplet excitons. One approach has been to add phosphorescent compounds to one of the layers in an EL device. Then triplet excitons can transfer to these phosphorescent molecules and emit light. In this study, multilayer organic light-emitting devices with phosphorescent emitter, tris (2-phenylpyridine)iridium ($Ir(ppy)_3$) were prepared. The device exhibited power luminous efficiency of 1.07 1m/W at the luminance of $61.6\;cd/m^2$ diriven at the voltage of 9 V and current density of $1.9mA/cm^2$. At the luminance of $100\;cd/m^2$, the luminous efficiency was obtained 1.05 lm/W with the voltage of 9.5 V and the corrent density of $2.8\;mA/cm^2$.

  • PDF

열교환기 내장형 어큐물레이터가 냉동시스템의 성능에 마치는 영향에 관한 연구 (Effects of Accumulator Heat Exchangers on the Performance of a Refrigeration System)

  • 강훈;최광민;박차식;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.433-438
    • /
    • 2005
  • An AHX(Accumulator Heat eXchanger) consists of a commercial accumulator and an inner heat exchanger located inside of the accumulator. The AHX is used in multi air-conditioners to assure the liquid-phase refrigerant entering into the expansion device. This purpose is achieved by heat transfer between the refrigerant leaving the evaporator and the refrigerant leaving the condenser. In this study, the effects of AHX on the performance of a refrigeration system using H-22 were measured and the test results were analyzed. The operating characteristics of the refrigeration system with the installation of AHX were quite different from those without the installation of AHX. Therefore, it is required to find an optimum refrigerant charging amount and optimum operating conditions, when AHX is installed in the refrigeration system with an fixed area expansion device such as a capillary tube.

  • PDF

CFC-대체냉매와 스크롤압축기를 사용한 냉동시스템 성능해석 (Performance Analysis of Refrigeration System Using the CFC-Alternative and Scroll Compressor)

  • 박희용;박경우
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.366-381
    • /
    • 1995
  • A performance analysis of refrigeration system using the HFC-134a and scroll compressor is performed numerically. The refrigeration system mainly consists of various standard components such as heat exchanger, compressor, and expansion device. The model for heat exchanger performance is based on a tube-by-tube method which is analyzed separately by considering the cross-flow heat transfer with the outdoor air flow and pressure drop. Compressor is used the scroll-type compressor which has many merits such as high efficiency, low noise and vibration, and small in size. Short-tube is included as an expansion device. Vapour and liquid line are also considered for the performance analysis of refrigeration system. Using the modeling of various components of refrigeration system, a performance comparison of CFC-12 and HFC-134a is performed numerically for the various outdoor air temperature and various values of short-tube diameter. As the results of this study, the refrigeration system performance decreases as the outdoor air temperature increases. And the optimum short-tube diameter based on COP is 1.37mm for this system.

  • PDF