• 제목/요약/키워드: Transfer constant

검색결과 1,068건 처리시간 0.022초

잠열 마이크로캡슐 슬러리의 열전달 특성 (Heat Transfer Characteristics of Micro-encapsulated Phase Change Material Slurry)

  • 박기원;김명준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.193-198
    • /
    • 2005
  • The present experiments have been performed for obtaining the melting heat transfer characteristics of micro-encapsulated solid-liquid phase change material and water mixed slurry flow in a circular tube heated with constant wall heat flux. The phase change material having a low melting point was selected for a domestic cooling system in the present study. The governing parameters were found to be latent heat material concentration, heat flux, and the slurry velocity. The experimental results revealed that the increase of tube wall temperature of latent microcapsule slurry was lower than that of water caused by the heat absorption of fusion.

  • PDF

자바 프로그램에서 메모리 영역 간 자료 이동에 따른 부담 분석 (Analysis of Data Transfer Overhead Among Memory Regions in Java Program)

  • 양희재
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제35권5호
    • /
    • pp.281-287
    • /
    • 2008
  • 자바 프로그램이 실행되면서 자료들은 상수에서 변수로, 변수에서 변수로 등 다양한 경로로 이동한다. 자료들은 메모리에 위치하며 자료의 이동은 메모리에 대한 접근을 필요로 한다. 메모리 접근은 시간지연과 에너지 소비를 야기하므로 여러 경로의 자료 이동이 어떤 부담을 갖는지를 아는 것은 효율적 프로그램 작성은 물론 고성능 자바가상기계의 구현에도 필수적이라 할 수 있다. 본 논문에서는 자바 메모리를 상수, 지역변수, 필드 등 세 가지 영역으로 나누고 각 영역 간의 자료 이동에 대한 부담을 조사하였다. 분석 결과 지역변수에서 지역변수로의 자료 이동이 가장 부담이 작고 필드에서 필드로의 이동이 가장 부담이 큰 것으로 조사 되었으며 부담 차이는 최대 2배에 이르는 것을 발견하였다. JIT 등 최적화 기술은 자료 이동 부담을 현저히 감소시켰으며 HotSpot JVM의 경우 최소 14배에서 최대 27배까지 부담 저하 효과를 나타내었다.

열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향 (An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe)

  • 최우석;박이동;김철주;황영규
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1995년도 춘계학술발표회 초록집
    • /
    • pp.69-76
    • /
    • 1995
  • The horizontal thermal storage tank with heat pipe which is suitable for the sensible heat storage system is able to store a hot water from the heat source such as heating pad efficiently and to supply a hot water to load rapidly. Therefore Arrangement of heating pad affects thermal flow and thermal storage efficiency. So, if effective arrangement is decided for condition of constant number of heating pad, the more rapid thermal flow effect and higher thermal storage efficiency is obtainable by active heat transfer. In this experiments, number of heating pad is ranged from three, five and nine, and when number of heating pad is constant, arrangement are two types of concentration-type and dispersion-type. As a result, for the case of concentration-type of heating pad, strong entrainment take place in horizontal thermal storage tank with heat pipe by active heat transfer and in the constant number of heating pad, the concentration-type has the higher efficiency with about 5∼6% than the dispersion-type. Therefore, when heating pad is equipted to horizontal thermal storage tank with heat pipe, concentration-type of heating pad is an efficient design in constant number. of heating pad.

  • PDF

혼합냉매를 사용한 열펌프 시스템의 성능과 열전달 특성 (Performance and Heat Transfer Characteristics of Heat Pump System Using Refrigerant Mixtures)

  • 김동섭;신지영;노승탁
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.360-369
    • /
    • 1992
  • A heat pump system is constructed to evaluate its performance and heat transfer characteristics with mixtures of R22/R142b as working fluids. The heat transfer in the evaporator and the overall performance are measured and analyzed in terms of the compositions and relevant variables. Possibility of capacity modulation by changing composition is observed without degradation of heat transfer coefficients and coefficient of performance. The cooling capacity is varied continuously within 200 percent based on minimum capacity at constant compressor speed. For similar cooling capacity, COP is improved by mixing two refrigerants and shows maximum value at 60% mass fraction of R22. Average heat transfer coefficients of mixtures decrease in comparison with pure refrigerants at similar cooling capacity and mass flow rate. However, the overall heat transfer coefficients decrease moderately. A cycle simulation is performed in order to manifest the advantages of using refrigerant mixtures, considering experimentally observed heat transfer characteristics.

  • PDF

수평관내 3성분 혼합냉매의 강제대류비등 열전달 (Forced convective boiling heat transfer for a ternary refrigerant mixture inside a horizontal tube)

  • 오종택
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.912-920
    • /
    • 1999
  • The forced convective boiling heat transfer coefficients of R-407C were measured inside a horizontal tube 6.0mm I.D. and 4.0m long. The heat transfer coefficients increased according to an increase in heat flux at constant mass flux. Because nucleation was completely suppressed in the two-phase flow region with high quality, heat transfer coefficients in forced convective evaporation were higher than those in nucleate boiling region. Average heat transfer coefficients of R-407C were about 30 percent lower than the pure refrigerant correlation, due to mass transfer resistance at the gas-liquid interface. However, the total experimental data shows an agreement with the predicted data for ternary refrigerant mixtures with a mean deviation of 30%.

  • PDF

Variability of Practice Effects in Transfer of Photoelectric Rotary Pursuit Task

  • Jeon, Hye-Seon
    • 한국전문물리치료학회지
    • /
    • 제12권4호
    • /
    • pp.7-11
    • /
    • 2005
  • The purposes of this study were to investigate the effects of variability of training on the acquisition of motor skill of closed loop type tracking task using Rotary Pursuit, and to determine if there was a bilateral transfer effect to the non-dominant hand following practice with the dominant hand. Twelve healthy volunteer students (5 males and 7 females, aged 25 to 37) were randomly divided into a constant practice group and a variable practice group. A photoelectric rotary pursuit apparatus with stop clock and repeat cycle timer by Lafayette Instrumentation Co. was used for this study. Rotary pursuit is a closed loop task in which a subject attempts to keep a photoelectric stylus on a lighted target in motion. Subjects performed the clockwise circular pursuit task while standing. Experimental procedure was divided into three sessions, namely, pre-test, training, and post-test. The constant group practiced all 60 trials at 30 rpm. Variable practice group did a varied practice session with 15 trials at speeds of 20 rpm, 26 rpm, 34 rpm, and 46 rpm. No one in either group practiced with their non-dominant arm. A Mann-Whitney test and a Wilcoxon Signed Ranks test were used for statistical analyses. The results of this study showed no different training effect between groups on the post-test with the dominant hand. However, bilateral transfer effect of rotary pursuit task between hands was demonstrated. Possible mechanisms are discussed.

  • PDF

이중 Moving Window 버퍼 기반 전달정렬 측정치 시간지연 보상기법 (Compensation Technique of Measurement Time Delay in Transfer Alignment Using the Double Moving Window Buffer)

  • 김천중;유준
    • 한국군사과학기술학회지
    • /
    • 제14권4호
    • /
    • pp.684-693
    • /
    • 2011
  • Measurement time delay in the transfer alignment is very important. It has been well known that the time delay degrades the alignment performance and makes some navigation errors on the transfer alignment of slave INS(SINS). Therefore there are many schemes to eliminate that time delay but the compensation technique through the estimation by Kalman filter through modeling the time delay as a random constant is generally used. In the case of change over measurement time delay or the large measurement time delay, estimation performance in the existing compensation technique is degraded because model of time delay is not correct any more. In this paper, we propose the method to keep the time delay almost constant even though in the abnormal communication state and very small through feedback compensation using double buffer. Double buffer consists of two moving window to temporarily store measurements from master INS and slave INS in real time.

가정용 보일러의 급탕시설 개선방안에 관한 연구 (A Study on the Improvement of the Water System in Domestic Boiler)

  • 한규일;박종운
    • 수산해양기술연구
    • /
    • 제34권2호
    • /
    • pp.200-211
    • /
    • 1998
  • Heat transfer performance improvement by fin and groovs is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapczodially shaped integral-fins having fin density from 748 to 1654fpm(fin per meter) and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also used for comparison. R-11 condensates at saturation state of 32 $^{\circ}C$ on the outside tube surface coded by inside water flow. All of test data are taken at steady state. The heat transfer loop is used for testing singe long tubes and cooling is pumped from a storage tank through filters and folwmeters to the horizontal test section where it is heated by steam condensing on the outside of the tubes. The pressure drop across the test section is measured by menas pressure gauge and manometer. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, overall heat transfer coefficients of finned tube are enhanced up to 1.6 ~ 3.7 times that of a plain tube at a constant Reynolds number. 2. Friction factors are up to 1.6 ~ 2.1 times those of plain tubes. 3. The constant pumping power ratio for the low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio. 4. A tube having a fin density of 1299fpm and 30 grooves has the best heat transfer performance.

  • PDF

Strainless steel strip 광휘어닐링로 내의 열전달 해석 (A Numerical Analysis of Heat Transfer in Bright Annealing Furnace of Stainless Steel Strip)

  • 유흥선;정연태;장병록
    • 열처리공학회지
    • /
    • 제22권4호
    • /
    • pp.228-233
    • /
    • 2009
  • In order to predict the temperature distribution of stainless steel strip in Bright Annealing (BA) furnace, we performed the analysis of heat transfer and fluid flow using STAR-CCM+. The analysis model included unsteady fluid flow, heat transfer with radiation and moving grid. Two kinds of radiative properties, emissivity and reflectivity, were applied to the stainless steel strip, one is constant and the other is variable with time. As we call, the BA furnaces of stainless steel strip have two different types, muffle and no-muffle. The using of muffle type has been faced with some problems such as rising in material price and shortening of life cycle, etc. So the development of no-muffle type BA furnace is very important in order to save energy cost, lower environmental load and increase the productivity. The designed (or expected) temperature of stainless steel strip coming out of BA furnace was about $1065^{\circ}C$ while the environment temperature maintains around $1100^{\circ}C$. The result of our calculation was very close (or similar) to design temperature, and the application of radiative properties variable with time produced more accurate result than applying constant ones.

Photoionization of N,N,N',N'-Tetramethyl-p-phenylenediamine in Polar Solvents

  • Min Yeong Lee;Du Jeon Jang;Minyung Lee;Du-Jeon Jang;Dongho Kim;Sun Sook Lee;Bong Hyun Boo
    • Bulletin of the Korean Chemical Society
    • /
    • 제12권4호
    • /
    • pp.429-433
    • /
    • 1991
  • The photoinduced electron transfer reactions of N,N,N',N'-tetramethyl-p-phenylenediamine (TMPD) in various polar solvents were studied by measuring time-resolved fluorescence. The temperature dependence on the fluorescence decay rate in acetonitrile, methanol, ethanol and buthanol was carried out to obtain the activation energy and Arrehnius factor for the photoinduced electron transfer reaction. It was found that as the dielectric constant of the solvent increases, the activation energy and the reaction rate increase. This implys that the Arrehnius factor is important in controlling the photoinduced electron transfer reaction rate. In water, TMPD exists in three forms (cationic, protonated and neutral forms) due to the high dielectric constant and strong proton donating power of water. The photoinduced electron transfer reaction was found to be very fast (< 50 ps) and also the long liverd component in the fluorescence decay profile attributable to the photoexcited protonated form of TMPD was observed. Probably, the reaction pathway and the reaction coordinate seem to be different depending on the solvents studied here.