• Title/Summary/Keyword: Transfer Space

검색결과 1,334건 처리시간 0.028초

Radiation Biology in Space; DNA Damage and Biological Effects of Space Radiation

  • Ohnishi, Takeo;Takahashi, Akihisa;Ohnishi, Ken
    • Journal of Photoscience
    • /
    • 제9권3호
    • /
    • pp.37-40
    • /
    • 2002
  • Astronauts are constantly exposed to space radiation at a low-dose rate during long-tenn stays in space. Therefore, it is important to determine correctly the biological effects of space radiation on human health. Space radiations contain various kinds of different energy particles, especially high linear energy transfer (LET) particles. Therefore, we have to study the relative biological effectiveness (RBE) of space radiation under microgravity environment which may change RBE from a stress for cells. Furthermore, the research about space radiation might give us useful information about birth and evolution of life on the earth. We also can realize the importance of preventing the ozone layer from depletion by use of exposure equipment to sunlight at International Space Station (ISS).

  • PDF

트랜스퍼 크레인 운영규칙에 관한 연구 (A Study about the Transfer Crane Operation Rules)

  • 김우선;최용석
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2004년도 춘계학술대회 논문집
    • /
    • pp.451-456
    • /
    • 2004
  • 본 연구에서는 장치장 운영규칙의 현실성을 높이기 위해서 트랜스퍼 크레인의 작업운영체계를 분석하고 작업우선순위의 적용을 위한 운영규칙의 적용방법을 설명하였다. 또한 장치장에서 주행로의 특성에 따른 대기 및 주행로 점거형태를 분석하여 블록에 진입하여 대기할 수 있는 최대 대기차량수를 도출할 수 있는 산정식을 정리하고 공간의 제약상태를 분석하였다. 또한 공간의 제약사항 극복하기 위해서 공간자원을 정의할 수 있는 다작업원칙을 제시하고 그 원칙을 위한 해법과 순서도를 묘사하였다.

  • PDF

KMTNet 자료 전송 실험 (DATA TRANSFER TEST FOR KMTNet DATA)

  • 김동진;이충욱;김승리
    • 천문학논총
    • /
    • 제30권1호
    • /
    • pp.31-38
    • /
    • 2015
  • We develop a real-time data transfer system for the Korea Microlensing Telescope Network (KMTNet) photometry data and test whether it is suitable for Korea Astronomy and Space Science Institute (KASI) and three different observatories, which are Cerro Tololo Inter-Ameriacan Observatory (CTIO) in Chile, Siding Springs Observatory (SSO) in Australia, and South African Astronomical Observatory (SAAO) in South Africa. For this test, we use a high speed global network being dedicated for researches. From the test, we obtain that the elapsed times between KASI and each three observatories, CTIO, SSO, and SAAO to transfer 650 MB of data are 99.0, 9.2, 119.0 seconds, respectively. This means that the system can be used for the real-time data processing of KMTNet.

온돌난방공간(溫突暖房空間)의 내표면(內表面) 복사열전달률(輻射熱傳達率)에 관(關)한 연구(硏究) (Radiation Heat-Transfer Coefficient of the Indoor Surface in Ondol Heating Space)

  • 손장열;안병욱;신용태
    • 대한설비공학회지:설비저널
    • /
    • 제17권5호
    • /
    • pp.598-606
    • /
    • 1988
  • The radiation heat-transfer coefficient is generally used to calculate radiant heat exchange of heating space. The coefficient is evenly adopted in most cases, but it is not correct in actual cases. The purpose of this paper is to grasp the changing aspect of radiation heat-transfer coefficient needed for heating load calculation of radiant heating space. Surface temperatures are measured in an Ondol space, and the coefficients are derived and examined. Gebhart's Absorption Factor Method is used for the calculations of the rates of instantaneous radiant exchange in the room. As the result, it is confirmed that the coefficients are variant according to surface temperatures, and proper coefficients are needed for each of conditions.

  • PDF

Solutions of Radiative Transfer for Nongray Gases within a 3-D Cylindrical Enclosure

  • Park, Won-Hee;Jung, Hyun-Sung;Kim, Tae-Kuk
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제3권1호
    • /
    • pp.30-38
    • /
    • 2002
  • In multi-dimensional systems, various solution schemes for radiative transfer are suggested but the applicabilities and accuracies of these schemes have not yet fully tested due to the lack of reference solutions especially for nongray gases. In this paper we present some precise radiative transfer solutions for a black walled 3-dimensional cylindrical system filled with nongray gases having uniform temperature and concentration. The ray-tracing method with the $T_N$ quadrature set and the SNB model are used to obtain the radiative transfer solutions by the nongray gases. The solutions presented in this paper are proved to be quite accurate and can be regarded as the reference solutions for the radiative transfer by nongray gases.

지하철 환승공간에서 경로탐색(wayfinding)을 위한 시환경 지각 요소에 관한 연구 - 지하철 사당역, 서울역, 종로3가역, 공덕역을 중심으로 - (Visual Performance Evaluation Study of Wayfinding Factors in Subway Transfer Station - Focus on the Sadang Subway Station, Seoul Subway Station, Jongro3-ga Subway Station and Gongduck Subway Station -)

  • 송현지;김남효
    • 한국실내디자인학회논문집
    • /
    • 제22권4호
    • /
    • pp.167-177
    • /
    • 2013
  • The environmental considerations should be taken into full consideration in order to make the use of ground space as comfort and efficient as that of ground space. The visual environmental factors which provide visual informations in underground spaces where the environmental information can be acquired only by the surroundings expand their role as affordance for wayfinding. This study focuses on the visual performance evaluation of wayfinding factors on the subway transfer station platform and aisle as major space for movement in four subway transfe stations and analyzes the material, pattern, color, and lighting provided by the visual environment in underground space as directional marked label, regional differentiation and sign system. The results of this study comes are as follows. First, As to the directional marked label at the subway platform and transfer aisle, following patterns are colors, finishing materials and lighting for the sake of safety and convenience, And regional differentiation, following colors are patterns for the space division. Finally sign system which practically provides the most information, however, it is most insufficient to be a space-preception element. Second, According to the type of platform structures, such as an island platform and a separate platform, the main areas of and necessity for the space-perception elements may bring about changes. Third, these four stations that has been analyzed for this study, lighting, compared with color, finishing material and pattern, has been highly insufficient to be a perception element.

ASPHERICAL DUST ENVELOPES AROUND OXYGEN-RICH AGB STARS

  • Suh, Kyung-Won
    • Journal of Astronomy and Space Sciences
    • /
    • 제23권4호
    • /
    • pp.303-310
    • /
    • 2006
  • We model the aspherical dust envelopes around O-rich AGB stars. We perform the radiative transfer model calculations for axisymmetric dust distributions. We simulate what could be observed from the aspherical dust envelopes around O-rich AGB stars by presenting the model spectral energy distributions and images at various wave-lengths for different optical depths and viewing angles. The model results are very different from the ones with spherically symmetric geometry.

루우버핀 열교환기의 핀피치가 공기측 열전달에 미치는 영향 (Effect of Fin Pitch on Air Side Heat Transfer in Louvered-Fin Heat Exchanger)

  • 장봉주;김선정
    • 태양에너지
    • /
    • 제20권3호
    • /
    • pp.31-38
    • /
    • 2000
  • In order to study on influence of fin pitch and shape of heat exchanger on the elevation of heat transfer efficiency, we make models of louvered fin type heat exchanger which was given a transformation of fin pitch in louvered fin type heat exchanger which are of en used now. And the influence of fin pitch on pressure drop and characteristics of heat transfer was experimented and analysed when air velocity and fin pitch was a variable. The results of experiment shows below. Pressure drop shows larger in louvered fin type heat exchanger than in plate fin type heat exchanger, size of pressure drop shows like this order that fin space is 4mm, 5mm, 6mm. Mean heat transfer coefficient shows higher in louvered fin type heat exchanger than in plate fin type heat exchanger, size of mean heat transfer coefficient by fin space shows same in both case in louvered fin type heat exchanger and plate fin type like this order that fin space is 4mm, 5mm, 6mm.

  • PDF

The Analysis of Heat Transfer through the Multi-layered Wall of the Insulating Package

  • Choi, Seung-Jin
    • 한국포장학회지
    • /
    • 제12권1호
    • /
    • pp.45-53
    • /
    • 2006
  • Thermal insulation is used in a variety of applications to protect temperature sensitive products from thermal damage. Several factors affect the performance of insulation packages. Among these factors, the thermal resistance of the insulating wall is the most important factor to determine the performance of the insulating package. In many cases, insulating wall consists of multi-layered structure and the heat transfer through this structure is a very complex process. In this study, an one-dimensional mathematical model, which includes all of the heat transfer principles covering conduction, convection and radiation in multi-layered structure, were developed. Based on this model, several heat transfer phenomena occurred in the air space between the layer of the insulating wall were investigated. From the simulation results, it was observed that the heat transfer through the air space between the layer were dominated by conduction and radiation and the low emissivity of the surface of each solid layer of the wall can dramatically increase the thermal resistance of the wall. For practical use, an equation was derived for the calculation of the thermal resistance of a multi-layered wall.

  • PDF

이중 버퍼 제어기 구조의 터보 복호기를 사용한 전송률 가변 비대칭 TDD 시스템 설계 (Design of Variable Data Transfer Rate Asymmetric TDD System Using Turbo Decoder with Double Buffer Controller)

  • 박병관;김미래;김효종
    • 한국항공우주학회지
    • /
    • 제47권2호
    • /
    • pp.161-168
    • /
    • 2019
  • 본 논문에서는 소형 무인기 데이터 링크 시스템에 적용이 가능한 전송률 가변 비대칭 TDD(Time Division Duplex) 방식에 대해 다루었다. 긴 복호 시간이 필요한 터보 복호기를 비대칭 TDD 방식에 적용하기 위하여 이중 버퍼 제어기 구조의 터보 복호기를 제안하였다. 제안 방법은 전송률 가변과 동일 송수신 시간에 최대의 데이터 전송이 가능하다. 제안 방식을 적용한 데이터 링크 시스템을 제작하여 성능을 확인하였다. 측정 결과, 대칭 TDD 방식에 비해 전송률은 최대 약 1.8배 증가하였다. PER(Packet Error Rate) 성능은 동일하며, 전송률 가변이 가능함을 확인하였다.