• 제목/요약/키워드: Transfer Module

검색결과 534건 처리시간 0.038초

전자모듈의 배열에 따른 열전달특성의 실험적 연구 (An Experimental Study of Heat Transfer Characteristics on the Electronic Module Arrangement)

  • 이대희;이대근;차윤석;이준식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2420-2425
    • /
    • 2007
  • Heat transfer from three-dimensional heat-generating modules was investigated. A simulated electronic module in an array configured with dummy module elements was used to measure the average heat transfer coefficients. Various module arrangements were tested using module spacings of 0.85 and 1.15 cm for six Reynolds numbers ranging from 500 to 975. The results show that a module placed in-line with and upstream of a heated module results in the heat transfer enhancement due to a high level in turbulence prompted by upstream modules. The highest enhancement occurs when the separation distance between modules is close to the module length in the flow direction. Flow visualization reveals laminar flow on the front of the first module, slow recirculation regions on the sides parallel to the air stream, and turbulence on the back side. It appears that the first module serves to trip the air stream and produce a high level of turbulence, which enhances the heat transfer rate downstream.

  • PDF

전자모듈의 배열에 따른 열전달특성의 실험적 연구 (An Experimental Study of Heat Transfer Characteristics on the Electronic Module Arrangement)

  • 이대희;이대근;차윤석;이준식
    • 대한기계학회논문집B
    • /
    • 제32권6호
    • /
    • pp.407-412
    • /
    • 2008
  • Heat transfer from three-dimensional heat-generating modules was investigated. Simulated electronic module in an array configured with dummy module elements were used to measure the average heat transfer coefficients. Various module arrangements were tested using module spacings of 0.85 and 1.15 cm for six Reynolds numbers ranging from 500 to 975. The results show that a module placed in-line with and upstream of a heated module results in the heat transfer enhancement due to high turbulence intensity prompted by upstream modules. The highest enhancement occurs when the separation distance between modules is close to the module length in the flow direction. The laminar flow was observed on the front of the first module, slow recirculation regions on the sides parallel to the airstream, and turbulent flow on the back side. It appears that the first module serves to trip the air stream and produce a high level of turbulence, which enhances the heat transfer rate downstream.

전산유동가시화를 활용한 웨이퍼 이송장치의 복사열전달에 관한 연구 (A Study on Radiation Heat Transfer of Wafer Transfer Module Using Computational Flow Visualization)

  • 추민기;정지홍;손동기;고한서
    • 한국가시화정보학회지
    • /
    • 제20권3호
    • /
    • pp.58-66
    • /
    • 2022
  • The high heat emitted from the process module and heat jacket may cause errors in semiconductor process equipment. Barriers were designed to reduce the temperature of surface on transfer module. A designed barrier was compared and analyzed by numerical analysis using ANSYS Fluent. The average temperature of barrier and effect of radiation heat transfer were also compared through absorbed radiative heat flux of the barrier. The adoption of the barrier had an effect on the radiative heat transfer reduction of the transfer module rod. The effect of the angles of barrier from 50° to 90° on the heat transfer was investigated using the absorbed radiative heat flux with the average temperature. The angle of barrier of 50° reduced the temperature up to 9.6 %.

A dust continuum radiative transfer module

  • Lee, Seokho;Lee, Jeong-Eun
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.55.1-55.1
    • /
    • 2016
  • We have developed a module for the dust continuum radiative transfer calculation as part of "Packages of Unified modeling for Radiative transfer, gas Energetics, and Chemistry (PUREC)". PUREC will be applied to interprete observations of protoplanetary disks. When a disk is under the hydrostatic equilibrium condition, the dust temperature and the vertical density structure should be calculated simultaneously. This module calculates the dust temperature by using the method of mean intensity (Lucy et al. 1999). In the very optically thick mid-palne, the Monte-carlo method is not efficient, thus, we apply "modified random walk" and "Partial Diffusion Approximation" to the module. The module has been verified by bechmark tests.

  • PDF

FMS 구축을 위한 제어 module 개발 (Development of control module for FMS construction)

  • 최홍태;배용환;박재홍;이석희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.1090-1095
    • /
    • 1992
  • This paper describes the systematic control method of process information transfer and machine cell control in FMS implementation. We have constructed an experimental FMS computer network and control system. The system hardware consists of host computer to manage process data and information transfer of machine cells, cell control computers to control machine cells(NC lathe, machining center). On the other hand, software is made up of oredr management module, NC program searching and generation module, NC part program error check module and cell control module. In this study, we could arrive at conclusion as following : The first, each task could be accomplihed by the efficient information transfer in hierachical computer network. The second, data base system of part programs and process control data is needed for the efficint information transfer and production management. Lastly, expansion of FMS control system could be achieved by the hierachical and decentralized computer control system.

  • PDF

흐름 영각에 따른 강제공랭 모듈 주위의 열전달 특성에 관한 연구 (A Study on the Heat Transfer Characteristics Around a Surface-Mounted Air-Cooled Module for the Flow Angle-of-Attack)

  • 박상희;신대종
    • 대한기계학회논문집B
    • /
    • 제26권9호
    • /
    • pp.1267-1275
    • /
    • 2002
  • An experimental study was performed to investigate adiabatic wall temperature and heat transfer coefficient around a module cooled by forced air flow. The flow angle of attack to the module were 0$^{\circ}$and 45$^{\circ}$. In the first method, inlet air flow(1~7m/s) and input power.(3, 5, 7W) were varied after a heated module was placed on an adiabatic floor(320$\times$550$\times$1㎣). An adiabatic wall temperature was determinated to use liquid crystal film. In the second method to determinate heat transfer coefficient, inlet air flow(1~7m/s) and the heat flux of rubber heater(0.031~0.062W/$m^2$) were varied after an adiabatic module was placed on rubber heater covering up an adiabatic floor. Additional information is visualized by an oil-film method of the surface flow on the floor and the module. Plots of $T_{ad}$ and $h_{ad}$ show marked effects of flow development from the module and dispersion of thermal wake near the module. Certain key features of the data set obtained by this investigation may serve as a benchmark for thermal-design codes based on CFD.

3차원 채널 밑면에 탑재된 모듈로부터의 혼합대류열전달 (Mixed Convection Transport from a Module on the Bottom Surface of Three Dimensional Channel)

  • 이진호;박상희;유갑종;방창훈
    • 대한기계학회논문집B
    • /
    • 제24권5호
    • /
    • pp.632-639
    • /
    • 2000
  • Conjugate heat transfer from a heat generating module ($31{\times}31{\times}7mm^3$) bonded through the module support on the floor of a parallel-plate channel(20mm high, 400mm wide, and 800mm long) to mixed convective air flow(0.2${\sim}$0.9m/s) is studied experimentally. The input power to the module is changed in a range 1.0${\sim}$4.5W, the floor thickness 0.2${\sim}$5mm, and the thermal resistance of module support, Rc:=0.06, 1.03 and 82.0K/W. Thermal conductance(Uc) of the board and convective thermal conductance($U_A$) from the module were derived, and the effect of V; Rc and t on Uc was investigated. It is found that the conjugate conductance (Uc) and the conductive heat transfer ratio ($Q_B$/Q) depend on the thermal resistance of the module support, the air velocity and the board thickness. The change of the module support resistance and the board thickness helps to elucidate the relative significance of heat transfer paths through the module support, the board, and from the board surface to the air. Additional information is investigated about the dependence of the heat transfer rate on the mixed convection parameter.

데이터 글로브와 진동모터를 이용한 촉각전달 및 제시 방법 (Tactile Transfer and Display Method using Data Glove and Vibration Motors Module)

  • 강형구;최영진
    • 제어로봇시스템학회논문지
    • /
    • 제19권12호
    • /
    • pp.1138-1144
    • /
    • 2013
  • This paper proposes a tactile transfer and display method between a data glove and vibration motors module. The data glove is developed to capture the hand postures and to measure the grip forces. The measured data are simplified with the proposed 5-bit transfer and display algorithm, and the vibration motors module is developed to display the measured hand posture and grip force to the operator. The proposed 5-bit algorithm contains both an 8-step hand posture and 4-step grip force level information for tactile transfer to the vibration motors module. Also, the effectiveness of the proposed method is shown through several experiments.

기판의 열확산에 의한 3차원 공랭모듈로부터의 열전달촉진에 관한 연구 (Enhancement of Heat Transfer from an Air-Cooled 3-Dimensional Module by means of Heat Spreading in the Board)

  • 박상희;홍택
    • 대한기계학회논문집B
    • /
    • 제26권7호
    • /
    • pp.1022-1030
    • /
    • 2002
  • The experiments were performed with a $31{\times}31{\times}7mm^3$ simulated 3-dimensional module on the thermal conductive board of a parallel plate channel. The convective thermal conductance for the path from the module surface directly to airflow and conjugate thermal conductance for the path leading from the module to the floor by way of a module support, then, to the airflow were determined with several combinations of module-support-construction(210, 0.32, 0.021 K/W)/floor-material(398, 0.236W/mK) and channel height(15-30mm). As the result, it was found that the conjugate thermal conductance and the temperature distribution around the module depend on the thermal resistance of the module support, and the channel height. These configurations were designed to investigate on the feasibility of using the substrate as an effective heat spreader in the forced convective air-cooling of surface mounted heat source. The experimental results were discussed in the light of interactive nature of heat transfer through two paths, one directed from the module to the airflow and the other via the module support and the floor to the air.

경사진 채널 밑면에 부착된 모사모듈의 복합열전달 (Conjugated heat transfer of the simulated module on the bottom of a inclined channel)

  • 이진호;조성훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.471-476
    • /
    • 2001
  • The characteristics of conjugated heat transfer in the inclined channel was experimentally investigated. The simulated module is attached to the bottom of the inclined channel and is heated with constant heat flux. The experimental parameters of this study are input power (Q = 3, 7W), inlet air velocity ($V_{i}=0.1{\sim}0.9m/s$) and inclined channel angle (${\varphi}=0{\sim}90^{\circ}$). The results show that input power was most effective parameter on the temperature differences between module and air. As the inclined channel angle increases, the temperatures of the module are increased. And we obtained the best condition on the conductive board when ${\varphi}=0^{\circ}$.

  • PDF