• Title/Summary/Keyword: Transfer Layer

Search Result 1,533, Processing Time 0.033 seconds

Various Modalities of Flap Surgery in Heel Pad Reconstruction (발뒤꿈치의 재건 시에 사용할 수 있는 다양한 피판술)

  • Jung, Yun-Ik;Lee, Dong-Won;Yoon, In-Sik;Rah, Dong-Kyun;Lee, Won-Jai
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.415-420
    • /
    • 2011
  • Purpose: The reconstruction of a soft tissue defect of the heel pad can be challenging. One vital issue is the restoration of the ability of the heel to bear the load of the body weight. Many surgeons prefer to use local flaps or free tissue transfer rather than a skin graft. In this study, we evaluated the criteria for choosing a proper flap for heel pad reconstruction. Methods: In this study, 23 cases of heel pad reconstruction were performed by using the flap technique. The etiologies of the heel defects included pressure sores, trauma, or wide excision of a malignant tumor. During the operation, the location, size and depth of the heel pad defect determined which flap was chosen. When the defect size was relatively small and the defect depth was limited to the subcutaneous layer, a local flap was used. A free flap was selected when the defect was so large and deep that almost entire heel pad had to be replaced. Results: There was only one complication of poor graft acceptance, involving partial flap necrosis. This patient experienced complete recovery after debridement of the necrotic tissue and a split thickness skin graft. None of the other transferred tissues had complications. During the follow-up period, the patients were reported satisfactory with both aesthetic and functional results. Conclusion: The heel pad reconstructive method is determined by the size and soft-tissue requirements of the defect. The proper choice of the donor flap allows to achieve satisfactory surgical outcomes in aesthetic and functional viewpoints with fewer complications.

하이브리드 화학증기증착법을 이용한 금속기판 위 그래핀의 저온합성

  • Lee, Byeong-Ju;Park, Se-Rin;Yu, Han-Yeong;Lee, Jeong-O;Jeong, Gu-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.77-77
    • /
    • 2010
  • 그래핀(Graphene)은 한 겹(layer)의 2차원 판상 구조에 탄소원자들이 육각형의 기본 형태로 배열되어 있는 나노재료로서, 우수한 역학적 강도와 화학적, 열적 안정성 및 흥미로운 전기 전자적 성질을 가지고 있는 것으로 알려져 있다. 최근, 이러한 특징적이고도 우수한 물성으로 인하여 기초물성 연구에서부터 차세대 응용까지 고려한 각종 연구들이 활발하게 진행되고 있다. 일반적으로 그래핀을 얻는 방법에는 물리 화학적 박리, 열화학증기증착법(TCVD), 탄화규소의 흑연화, 흑연산화물의 환원 등의 방법들이 알려져 있다. 그 중 TCVD법이 두께의 균일성이 높은 그래핀을 합성하는데 가장 적절한 것으로 알려져 있다. 그러나 TCVD법은 탄소를 포함하는 원료가스를 분해하기 위하여 고온의 공정을 필요로 하게 되지만, 향후 산업적 응용을 고려한다면 대면적 그래핀의 저온합성법 개발은 풀어야 할 시급한 과제로 인식되고 있다. 현재는 메탄을 원료가스로 사용하여 $900^{\circ}C$ 이상에서 그래핀을 합성하는 추세이고, 최근 아세틸렌등의 활성원료가스를 이용하여 $900^{\circ}C$ 이하에서 저온 합성한 연구결과들도 속속 보고되고 있다. 본 연구에서는 고주파 플라즈마를 이용하여 비교적 저온에서 탄소원료가스를 효율적으로 분해하고, 확산플라즈마 영역에 TCVD 챔버를 결합한 하이브리드 화학증기증착법을 이용하여 그래핀의 저온합성을 도모하였다. 원료가스로는 메탄을 사용하였고, 기판으로는 전자빔증착법으로 증착한 니켈 박막 및 구리포일을 사용하였다. 실험결과, 그래핀은 $600^{\circ}C$ 부근의 저온에서도 수 층으로 이루어진 그래핀이 합성된 것을 확인하였다. 합성한 그래핀은 분석의 용이함 및 향후 다양한 응용을 위하여 실리콘산화막 및 투명고분자 기판 위에 전사(transfer)하였다. 합성된 그래핀의 구조평가를 위해서는 광학현미경과 Raman분광기를 주로 사용하였으며, 원자힘현미경(AFM), 주사전자현미경(SEM), 투과전자현미경(TEM) 등도 이용하였다.

  • PDF

A Study on the Thermoacoustic Oscillation of an Air Column (기주의 열음향진동에 관한 연구)

  • 권영필;이병호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.253-261
    • /
    • 1987
  • Thermoacoustic oscillation of an air column induced by heated wires is investigated analytically and experimentally. Acoustic power generation from a single heater wire is estimated based on the result of heat transfer analysis and expressed in terms of the efficiency factor indicating the conversion efficiency from heat to acoustic energy. It is shown that the efficiency factor becomes maximum when the wire radius is the order of the coustic boundary layer thickness and the flow velocity is close to the thermal diffusion velocity. Onset condition of the column oscillation is obtained by equating the acoustic power generation at the heater to the power loss due to thermoviscous dissipation at the tube wall and the convection and radiationloss at the open ends of the tube. In estimating the acoustic power generation, the heater is treated as a stretched single wire by correcting the flow velocity to take into account the interactions between adjacent heater wires. Experiment is performed by using a spiral heater of 1mm diameter in an air column of 37mm diameter. The heat input to drive the oscillation is measured and compared with the theoretical prediction. A good agreement is found between the theory and experiment, which is regarded as a substantial verification of the present analysis.

A Wireless Sensor Network Architecture and Security Protocol for Monitoring the State of Bridge (교량감시를 위한 무선 센서 네트워크 구조 및 보안 프로토콜)

  • Lim Hwa-Jung;Jeon Jin-Soon;Lee Heon-Guil
    • Journal of the Korea Computer Industry Society
    • /
    • v.6 no.3
    • /
    • pp.465-476
    • /
    • 2005
  • The wireless sensor network consists of a number of sensor nodes which have physical constraints. Each sensor node senses surrounding environments and sends the sensed information to Sink. In order to alleviate the inherent vulnerability in security of the wireless sensor nodes with the hardware constraints, the lightweight security protocol is needed and a variety of research is ongoing. In this paper, we propose a non-hierarchical sensor network and a security protocol that is suitable for monitoring man-made objects such as bridges. This paper, furthermore, explores a two-layer authentication, key distribution scheme which distributes the key and location of a sensor node in advance, and an effective security routing protocol which can take advantage of the Sleep and Awake state. This also results in the increased data transfer rate by increasing the number of alternative routing paths and the reduced energy consumption rate.

  • PDF

Complete genome sequence of Betaproteobacteria strain GR16-43 isolated form a freshwater pond in South Korea (담수에서 분리한 Betaproteobacteria GR16-43의 유전체 염기서열 분석)

  • Choi, Ahyoung;Baek, Kiwoon;Chung, Eu Jin;Kim, Jee-Hwan;Choi, Gang-Guk
    • Korean Journal of Microbiology
    • /
    • v.53 no.4
    • /
    • pp.320-322
    • /
    • 2017
  • A betaproteobacterium strain GR16-43 was isolated from a surface layer of the Geomnyong Pond in Republic of Korea by a dilution-to-extinction culturing method. We report the whole genome sequence of the strain GR16-43, which contains 4,806,848 bp with a G + C content 67.12%, and to include 4,424 protein-coding genes and 47 transfer RNA genes. The genome was determined to contain the genes encoding carbon monoxide dehydrogenase, nitrate reductase, nitrite reductase, nitric oxide reductase, and the sulfur oxidation (sox) gene cluster, highlighting the potential importance of the bacterial group represented by the strain in the cycling of inorganic elements. These results indicate that strain GR16-43 genome showed several traits indicating adaptation of the bacteria to living in freshwater environments.

Study of Corrosion of Brass Coated Steel Cords in the Acetonitrile Solution of Sulfenamide Derivatives by Tafel Plot and AC Impedance Measurements

  • Young Chun Ko;Byung Ho Park;Hae Jin Kim;Q Won Choi;Jongbaik Ree;Keun Ho Chung
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.2
    • /
    • pp.122-126
    • /
    • 1994
  • Corrosion of brass coated steel cords in the acetonitrile solution of sulfenamide derivatives, N-Cyclohexylbenzothiazole-2-sulfenamide (CBTS), N,N'-Dicyclohexylbenzothiazole-2-sulfenamide (DCBS), N-tert-Butylbenzothiazole-2-sulfenamide (TBBS), N-tert-Amylbenzothiazole-2-sulfenamide (TABS), and N-Oxydiethylbenzothiazole-2-sulfenamide (OBTS) was investigated by potentiostatic anodic and cathodic polarization (Tafel plot), DC polarization resistance, and AC impedance measurements. The corrosion current densities and rates are 1.236 ${\mu}A /cm^2$ and 0.655 MPY for CBTS; 1.881 ${\mu}A/cm^2$ and 0.988 MPY for DCBS; 2.367 ${\mu}A/cm^2$ and 1.257 MPY for TBBS; 3.398 ${\mu}A /cm^2$ and 1.809 MPY for TABS, respectively. OBTS among derivatives under study shows the lowest corrosion density (0.546 ${\mu}A /cm^2$) and the slowest corrosion rate (0.288 MPY). Also, the charge transfer resistances and the double layer capacitances are 275.21 $k{\Omega}{\cdot}cm^2$ and 7.0 ${\mu}F{cdot}cm^{-2}$ for CBTS; 14.24 ${\mu}F{\cdot}cm^2$ and 26 ${\mu}F{\cdot}cm^{-2}$ for DCBS; 54.15 $k{\Omega}{\cdot}cm^2$ and 26 ${\mu}F{\cdot}cm^{-2}$ for TBBS; 0.96$k{\Omega}{\cdot}cm^2$ and 83 ${\mu}F{\cdot}cm^{-2}$ for TABS, respectively. The weaker the electron donating inductive effect of derivatives is and the smaller the effect of steric hindrance is, the more the corrosion of brass coated steel cords in the acetonitrile solution of sulfenamide derivatives is prevented. The above results agree with that observed in the field of tire industry.

Development of a Hierarchical HydroG-OneFlow Web Services of River GeoSpatial Information (하천공간정보의 계층적 HydroG-OneFlow 웹서비스 개발)

  • Shin, Hyung Jin;Hwang, Eui Ho;Chae, Hyo Sok;Hong, Sung Soo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.626-626
    • /
    • 2015
  • 본 연구에서는 하천공간정보의 웹서비스를 위해 SOAP(Simple Object Access Protocol) API 및 REST(Representation State Transfer) API로 제공하는 HydroG-OneFlow 웹서비스를 개발하였다. HydroG-OneFlow는 GML 기반의 서비스를 제공하며 GetBasin, GetGeoVariable 및 GetData 등의 기본서비스로 구성된다. GML은 GIS S/W의 벡터 GML 포맷과 공간정보 오픈플랫폼 서비스인 브이월드 데이터 API에서 제공하는 GML 포맷을 참고하여 하천공간 벡터정보를 제공할 수 있도록 GML을 구성하였다. GDM 공간 데이터에 대한 벡터정보 ML 수용 수준을 향상시킬 수 있도록 벡터구조의 점, 선, 면 정보에 대하여 GML의 PointPropertyType, CurvePropertyType, SurfacePropertyType을 도입하였다. 또한 일반적인 공간자료에서는 Multi 객체에 대한 지원도 필요하다. 현 GDM 데이터베이스에서도 OGC 표준의 MultiPoint, MultiLineString, MultiPolygon을 지원하고 있다. 이를 위하여 GML의 상응 요소인MultiPointPropertyType, MultiCurvePropertyType, MultiSurfacePropertyType을 하천공간정보 벡터 스키마에 도입하여 활용하였다. 클라이언트 서버 통신은 메시지 교환프로토콜인 SOAP을 사용하여 서버의 객체를 직접 호출하여 이루어진다. 서버는 서버의 제공 서비스를 WSDL(Web Service Description Language)를 통하여 게시하고 클라이언트는 이 기준(Criteria)을 참고하여 접근한다. GetData의 경우 Type(GRID or VECTOR), GDM(Geospatial Data Model) 여부(true or false), LayerName, BasinID, GenTime을 인자로 받아 GeoData에서 검색된 정보를 반환한다. SOAP버전은 1.1과 1.2를 지원하여 접근하는 클라이언트에서 선택할 수 있도록 개발하였다.

  • PDF

Characteristic Study on Effect of the Vent Mixer to Supersonic Fuel-Air Mixing with Stereoscopic-PIV Method (3차원 PIV 기법을 사용한 벤트혼합기가 초음속 연료-공기 혼합에 미치는 특성 연구)

  • Kim, Chae-Hyoung;Jeung, In-Seuck;Choi, Byung-Il;Kouchi, Toshinori;Masuya, Goro
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.4
    • /
    • pp.50-56
    • /
    • 2012
  • Vent mixer can provide main flow directly into a recirculation region downstream of the mixer to enhance fuel-air mixing efficiency. Based on experimental results of three-dimensional velocity, vorticity and turbulent kinetic energy obtained by a stereoscopic PIV method, the performance of the vent mixer was compared with that of the step mixer which was used as a basic model. Thick shear layers of the vent mixer induced the increase of the penetration height. The turbulent kinetic energy mainly distributed along a boundary layer between the main flow and the jet plume. This turbulent field activates mass transfer in a mixing region, leading to the mixing enhancement.

Analysis of Resonant Characteristics in High Voltage Windings of Main Transformer for Railway Vehicle using EMTP (EMTP를 이용한 철도차량용 주변압기 고압권선의 공진특성 분석)

  • Jeong, Ki-Seok;Jang, Dong-Uk;Chung, Jong-Duk
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.436-444
    • /
    • 2016
  • The primary windings of the main transformer for rolling stock have several natural frequencies that can occur internal resonance with transient voltages induced on a high voltage feeding line. Factory testing is limited in its ability to determine whether or not transient voltage with various shape and duration can be excitable. This study presents the design of a high voltage windings model and simulation and analysis of the internal resonant characteristics in terms of the initial voltage distribution and voltage-frequency relationship using the electromagnetic transients program (EMTP). Turn-based lumped-parameters are calculated using the geometry data of the transformer. And, sub-models, being grouped into the total number of layers, are composed using a ladder-network model and implemented by the library function of EMTP. Case studies are used to show the layer-based voltage-frequency relationship characteristics according to the frequency sweep and the voltage escalation and distribution aspects in time-domain simulation.

A Study on the Chilling Start-up Characteristics and Performance of a Gas Loaded Heat Pipe (가스내장 히트파이프의 냉시동특성과 성능에 관한 연구)

  • Hong, Sung-Eun;Kang, Hwan-Kook
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.11
    • /
    • pp.915-922
    • /
    • 2006
  • Considering heat pipe design principles in fabrication and operational performances, water is one of the most recommended working fluids to make mid to low tempera lure heat pipes. But the conventional water heat pipes might encounter the failure in a cold start-up operation when socked at a chilling temperature lower than the freezing point. If they are subjected to a heat supply for start-up at a temperature around $-20^{\circ}C$, the rate of the vapor flow and the corresponding heat transfer from the evaporator to the condenser is so small that the vapor keeps to stick on the surface of the chilling condenser wall, forming an ice layer, resulting in a liquid deficiency in the evaporator. This kind of problems was resolved by Kang et al. in 2004 by adopting a gas loading heat pipe technology to the conventional water heat pipes. This study was conducted to examine a chilling start-up procedure of gas loading heat pipes by investigating the behaviors of heat pipe wall temperatures. And the thermal resistance of the gas loaded heat pipe that depends on the operating temperatures and heat loads was measured and examined. Two water heat pipes were designed and fabricated for the comparison of performances, one conventional and the other loaded with $N_2$ gas. They were put on start-up test at a heat supply of 30 W after having been socked at an initial temperature around $-20^{\circ}C$. It was observed that the gas loaded one had succeeded in chilling start-up operation.