• Title/Summary/Keyword: Transfer Factor Analysis

Search Result 554, Processing Time 0.029 seconds

Performance and Heat transfer Characteristics of Louver Fin-tube Heat Exchanger for Simultaneous Cooling/Heating Heat Pump (동시 냉난방 히트펌프용 루버핀-관 열교환기 성능 및 전열특성 실험연구)

  • Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1337-1342
    • /
    • 2007
  • An experimental study has been performed to investigate the performance and heat transfer characteristics of the heat exchanger for simultaneous cooling/heating heat pump. The heat transfer performance was measured using an air-enthalpy calorimeter and a constant temperature water bath, to obtain the performance evaluation and analysis of a fined tube heat exchanger. Six finned tube heat exchangers with louver fin were tested under a heating condition. Air-side heat transfer and friction were presented in terms of j-factor and f-factor. The heat transfer coefficient increased with decreasing the fin pitch, j-factor and f-factor on the fin pitch and the number of tube rows decreased with increasing Reair.

  • PDF

Design Optimization of Pin-Fin Sharp to Enhance Heat Transfer

  • Li, Ping;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.185-190
    • /
    • 2005
  • This work presents a numerical procedure to optimize the elliptic-shaped pin fin arrays to enhance turbulent heat transfer. The response surface method is used as an optimization technique with Reynolds-averaged Navier Stokes analysis of flow and heat transfer. Shear stress transport (SST) turbulence model is used as a turbulence closure. Computational results for average heat transfer rate show a reasonable agreement with the experimental data. Four variables including major axis length, minor axis length, pitch and the pin fin length nondimensionalized by duct height are chosen as design variables. The objective function is defined as a linear combination of heat transfer and friction-loss related terms with weighting factor. D-optimal design is used to reduce the data points, and, with only 28 points, reliable response surface is obtained. Optimum shapes of the pin-fin arrays have been obtained in the range from 0.0 to 0.1 of weighting factor.

  • PDF

Development of a Sound Quality Index for the Evaluation of an Intake Noise of a Passenger Car (급가속시 차량의 흡기소음에 대한 음질지수 개발)

  • Lee, J.K.;Park, Y.W.;Chai, J.B.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.8 s.101
    • /
    • pp.939-944
    • /
    • 2005
  • In this paper, a sound quality index for the evaluation of the vehicle intake noise was developed through a correlation analysis of the objective measurement and the subjective evaluation. First, intake orifice noise was measured at the wide-open throttle sweep condition. And then, the acoustic transfer function between intake orifice noise and interior noise was measured. Simultaneously, subjective evaluation was carried out with a 10-scale score by 8 special engineers. The correlation analysis between the psychoacoustic parameters derived from the measurement and the subjective evaluation was performed. The most critical factor was determined and the corresponding sound quality index for intake noise was obtained from the multiple factor regression analysis method. Finally, the effectiveness of the proposed index was validated.

FATIGUE ANALYSIS OF A REACTOR PRESSURE VESSEL FOR SMART

  • Jhung, Myung-Jo
    • Nuclear Engineering and Technology
    • /
    • v.44 no.6
    • /
    • pp.683-688
    • /
    • 2012
  • The structural integrity of mechanical components during several transients should be assured in the design stage. This requires a fatigue analysis including thermal and stress analyses. As an example, this study performs a fatigue analysis of the reactor pressure vessel of SMART during arbitrary transients. Using heat transfer coefficients determined based on the operating environments, a transient thermal analysis is performed and the results are applied to a finite element model along with the pressure to calculate the stresses. The total stress intensity range and cumulative fatigue usage factor are investigated to determine the adequacy of the design.

Research on heat transfer coefficient of supercritical water based on factorial and correspondence analysis

  • Xiang, Feng;Tao, Zhou;Jialei, Zhang;Boya, Zhang;Dongliang, Ma
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1409-1416
    • /
    • 2020
  • The study of heat transfer coefficient of supercritical water plays an important role in improving the heat transfer efficiency of the reactor. Taking the supercritical natural circulation experimental bench as the research object, the effects of power, flow, pipe diameter and mainstream temperature on the heat transfer coefficient of supercritical water were studied. At the same time, the experimental data of Chen Yuzhou's supercritical water heat transfer coefficient was collected. Through the factorial design method, the influence of different factors and their interactions on the heat transfer coefficient of supercritical water is analyzed. Through the corresponding analysis method, the influencing factors of different levels of heat transfer coefficient are analyzed. It can be found: Except for the effects of flow rate, power, power-temperature and temperature, the influence of other factors on the natural circulation heat transfer coefficient of supercritical water is negligible. When the heat transfer coefficient is low, it is mainly affected by the pipe diameter. As the heat transfer coefficient is further increased, it is mainly affected by temperature and power. When the heat transfer coefficient is at a large level, the influence of the flow rate is the largest at this time.

Stability Analysis of Anchored Slope Considering Load Transfer (하중전이를 고려한 앵커보강사면의 안정해석)

  • Kim, Nak-Kyung;Yun, Seung-Kwon;Kim, Sung-Kyu;Joo, Yong-Sun;Park, Jong-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.1113-1124
    • /
    • 2009
  • The limit equilibrium method and finite element method have been commonly used to assess the stability of anchored slope. However, the existing limit equilibrium methods do not consider the load transfer of anchor and, if the potential failure surface crosses the bonded zone of anchors, the anchor loads are not included in computing the factor of safety. In this paper, simplified bishop method, one among several methods based on the limit equilibrium is used to develope the Excel Sheet program and the working load of anchor along the failure surface is calculated by Flamant's formula, proposed by Morlier and Tenier(1982). Additionally, the finite element analysis of anchored slope considering the load transfer is performed in order to compare with the result from the limit equilibrium analysis and analyze the reinforced effect of anchor. From this study, new modelling method that limits the reinforcing range and considers the load transfer is proposed and Excel Sheet program is developed. The factor of safety for several cases between PC STABL and Excel Sheet program is also compared for verification of the program.

  • PDF

Numerical and random simulation procedure for preliminary local site characterization and site factor assessing

  • Beneldjouzi, Mohamed;Laouami, Nasser;Slimani, Abdennasser
    • Earthquakes and Structures
    • /
    • v.13 no.1
    • /
    • pp.79-87
    • /
    • 2017
  • Seismic analysis of local site conditions is fundamental for a reliable site seismic hazard assessment. It plays a major role in mitigation of seismic damage potential through the prediction of surface ground motion in terms of amplitude, frequency content and duration. Such analysis requires the determination of the transfer function, which is a simple tool for characterizing a soil profile by estimating its vibration frequencies and its amplification potential. In this study, numerical simulations are carried out and are then combined with a statistical study to allow the characterization of design sites classified by the Algerian Building Seismic Code (RPA99, ver 2003), by average transfer functions. The mean transfer functions are thereafter used to compute RPA99 average site factors. In this regard, coming up seismic fields are simulated based on Power Spectral Density Functions (PSDF) defined at the rock basement. Results are also used to compute average site factor where, actual and synthetic time histories are introduced. In absence of measurement data, it is found that the proposed approach can be used for a better soil characterization.

The Effects of Business Startup Education of Restaurant Founder on Transfer Effect in Learning and Entrepreneurial Intentions

  • Hwang, Gyu-Sam;Jung, Hun-Jung;Kim, Hae-Ryong;Shin, Choung-Seob
    • East Asian Journal of Business Economics (EAJBE)
    • /
    • v.5 no.4
    • /
    • pp.20-38
    • /
    • 2017
  • Purpose - this study analyzes the impact of restaurant startup education on transfer effects in learning and entrepreneurial intentions based on previous research. Also, problems and ways to provide effective business startup education for a restaurant founder will be proposed based on the result. Research design, data, methodolog - this study collected surveys by conducting direct investigation. From July 20th of 2016 to September 20th of 2016 (approximately 60 days), the survey was collected. Out of 540 surveys, 520 were collected. And excepting 9 surveys which were untrustworthily conducted, total 511 surveys were used for the analysis. Results - First, as a result of the impact of which factor of a restaurant founder's startup education has a positive impact on transfer effect in learning (the satisfaction of startup education and learning transfer), law education, entrepreneurship education and business district analysis education and practical education have turned out be positively related variables. Secondly, as a result of the impact of a restaurant founder's startup education satisfaction on transfer in learning, it has been identified that startup education has a positive impact. Lastly, by conducting an analysis to find out which factor from a restaurant founder's transfer effect in learning has an impact on entrepreneurial intention, all variables, including startup education satisfaction and transfer effect in learning, are positively influencing factors. Conclusions - as startup education satisfaction of a restaurant founder is increasing, there is a higher level of transfer effect in learning. Moreover, as transfer effect of startup business is getting higher, it has an impact on entrepreneurial intention.

Numerical Analysis for the Air-Side Convective Heat Transfer Characteristics in a Compact Heat Exchanger with Circular Tubes and Continuous Plate Fins (원형관-평판휜 형상의 밀집형 열교환기 내 공기 측대류열전달특성에 대한 수치해석)

  • Moh, Jeong-Hah;Lee, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.12
    • /
    • pp.994-1001
    • /
    • 2007
  • Numerical analysis has been carried out to investigate air-side convective heat transfer characteristics in a compact heat exchanger with circular tubes and continuous plate fins. Simulation results such as air velocity and temperature distributions are presented, and heat transfer coefficients are compared with previous experimental correlations. Three models of standard and RNG $k-{\varepsilon}$, and Reynolds stress are applied for turbulence model applicability. Predicted heat transfer coefficient from the models of standard and RNG $k-{\varepsilon}$ are very close to those of the heat transfer correlations while there are relatively large difference, more than 17 percentage in the result from the Reynolds stress model. From the calculated results a correlation for Colburn j factor in the compact heat exchanger system is suggested.

Development of an Index for the Evaluation of Intake Booming Noise of a Passenger Car (차량의 흡기부밍소음 평가지수 개발)

  • Park Y. W.;Chai J. B.;Jang H. K.;Lee J. K.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.9 s.90
    • /
    • pp.884-890
    • /
    • 2004
  • In this paper, an index for the evaluation of vehicle intake booming noise is developed through a correlation analysis of objective measurement data and subjective evaluation data. First, intake orifice noise is measured at the wide-open test condition. And then, acoustic transfer function between intake orifice noise and interior noise at the steady state condition is estimated. Simultaneously, subjective evaluation was carried out with a ten-scale score by 8 engineers. Next, the correlation analysis between the psycho-acoustic parameters derived from the measured data and the subjective evaluation is performed. The most critical factor was determined and the corresponding index for the intake booming noise is obtained from the multiple factor regression method. At last, the effectiveness of the proposed index is validated.