• Title/Summary/Keyword: Transfer Distance

Search Result 890, Processing Time 0.024 seconds

NIRS Calibration Equation Development and Validation for Total Nitrogen Contents Field Analysis in Fresh Rice Leaves (벼 생엽의 질소함량 현장분석을 위한 NIRS 검량식 개발 및 검증)

  • Song, Young-Eun;Lee, Deok-Ryeol;Cho, Seong-Hyun;Lee, Ki-Kwon;Jeong, Jong-Seong;Gwon, Yeong-Rip;Cho, Kyu Chae
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.58 no.3
    • /
    • pp.301-307
    • /
    • 2013
  • This study was evaluated high end research grade Near Infrared Reflectance Spectrophotometer (NIRS) to field grade multiple Near Infrared Reflectance Spectrophotometer (NIRS) for rapid analysis at fresh rice leaf at sight with 238 samples of fresh rice leaf during year 2012, collected Jeollabuk-do for evaluate accuracy and precision between instruments. Firstly collected and build database high end research grade NIRS using with 400 nm ~ 2500 nm during from year 2003 to year 2009, seven years collected fresh rice leaf database then trim and fit to field grade NIRS with 1200 nm ~ 2400 nm then build and create calibration, transfer calibration with special transfer algorithm. The result between instruments was 0.005% differences, rapidly analysis for chemical constituents, Total nitrogen in fresh rice leaf within 5 minutes at sight and the result equivalent with laboratory data. Nevertheless last during more than 8 years collected samples for build calibration was organic samples that make differentiate by local or yearly bases etc. This strongly suggest population evaluation technique needed and constantly update calibration and maintenance calibration to proper handling database accumulation and spread out by knowledgable control laboratory analysis and reflect calibration update such as powerful control center needed for long lasting usage of fresh rice leaf analysis with NIRS at sight. Especially the agriculture products such as rice will continuously changes that made easily find out the changes and update routinely, if not near future NIRS was worthless due to those changes. Many research related NIRS was shortly study not long term study that made not well using NIRS, so the system needed check simple and instantly using with local language supported signal methods global distance (GD) and neighbour distance (ND) algorithm. Finally the multiple popular field grades instruments should be the same results not only between research grade instruments but also between multiple field grade instruments that needed easily transfer calibration and maintenance between instruments via internet networking techniques.

Characteristic Study of Small-sized and Planer Resonator for Mobile Device in Magnetic Wireless Power Transfer (소형 모바일 기기용 공진형 무선전력전송 시스템의 공진기 평면화 및 소형화에 따른 특성 연구)

  • Lee, Hoon-Hee;Jung, Chang-Won
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.4
    • /
    • pp.16-21
    • /
    • 2017
  • In this paper, a Small-sized and planer resonator design of Magnetic Resonance - Wireless Power Transfer(MR-WPT) were proposed for practical applications of mobile devices, such as a laptop, a smart-phone and a tablet pc. The proposed MR-WPT system were based on four coil MR-WPT and designed as a transmitter part (Tx) and a receiver part (Rx) both are the same shape with the same loop and resonator. There are four different spiral coil type of resonators with variable of line length, width, gap and turns in $50mm{\times}50mm$ size. The both of top and bottom side of substrate(acrylic; ${\varepsilon}_r=2.56$, tan ${\delta}=0.008$) ere used to generate high inductance and capacitance in limited small volume. Loops were designed on the same plane of resonator to reduce their volume, and there are three different size. The proposed MR-WPT system were fabricated with two acrylic substrate plane of Tx and Rx each, the Rx and Tx loops and resonators were fabricated of copper sheets. There are 12 combinations of 3 loops and 4 resonators, each combination were measured to calculate transfer efficiency and resonance frequency in transfer distance from 1cm to 5cm. The measured results, the highest transfer efficiency was about 70%, and average transfer efficiency was 40%, on the resonance frequency was about 6.78 MHz, which is standard band by A4WP. We proposed small-sized and planer resonator of MR-WPT and showed possibility of mobile applications for small devices.

A study on the accuracy of source position in HDR brachytherapy according to the curvature of Universal applicator transfer tube and applicator type (원격 후 장전치료기를 사용한 고선량률 근접치료시 기구의 형태와 선원 전달 도관의 곡률 변화에 따른 선원위치 정확성에 관한 고찰)

  • Shin, Hyeon Kyung;Lee, Sang Kyoo;Kim, Joo Ho;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • Purpose : The goal of this study was to verify and analyze the source position according to the curvature of the universal applicator and 4 different angle applicators when using RALS(Remote After Loading System). Materials and Methods : An interval of 1 cm and 15 second dwell times in each source position were applied for plan. To verify the accuracy of source position, we narrowed the distance between MultiSource container and GAFCHROMIC$^{(R)}$ EBT3 film by 5 cm, 10 cm, 20 cm so that the universal applicator transfer tube had some curvature. Also 4 applicators(Intrauterine tube: $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, Ovoid tube: $65^{\circ}$) were used in the same condition. The differences between desired and actual source position were measured by using Image J. Results : In case of using 4 different angles of applicator with the straight universal applicator transfer tube, the average error was the lowest for $0^{\circ}$ applicator, greatest for $65^{\circ}$ applicator. However, All average errors were within ${\pm}2mm$ recommended in TG-56. When MultiSource container was moved 5 cm, 10 cm, 20 cm towards the EBT3 film, the average errors were beyond ${\pm}2mm$. The first dwell position was relatively located in accuracy, while the second and third dwells were displaced by an increasing magnitude with increasing curvature of the transfer tube. Furthermore, with increasing the angle of applicators, the error of all other dwell positioning was increased. Conclusion : The results of this study showed that both the curvature of universal applicator transfer tube and the angle of applicators affect the source dwell position. It is recommended that using straight universal applicator transfer tubes is followed in all cases, in order to avoid deviations in the delivered source dwell position. Also, It is advisable to verify the actual dwell position, using video camera quality control tool prior to all treatments.

  • PDF

Utilizing Usability Metrics to Evaluate a Subway Map Design

  • Jung, Kwang Tae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.4
    • /
    • pp.343-353
    • /
    • 2017
  • Objective: This study aims to evaluate the efficiency of two representative subway map design types, namely a diagram type and a geographical type using physiological metrics, performance metrics, and self-reported metrics, which are representative usability metrics. Background: Subway maps need to be designed in order for users to quickly search and recognize subway line information. Although most cities' subway maps currently use the diagram type designed by Henry Beck, New York City's subway map has recently been changed to the subway map type combined with the geographical type designed by Michael Hertz. However, not many studies on its efficiency are found, and the studies that are available mainly depend on questionnaire surveys or take on a subjective behavioral study type based on experts' experiences. In this regard, evaluation through a more objective method is needed. Method: This study employed usability metrics as a method to evaluate the efficiency of information search targeting the diagram type and geographical type subway maps used mostly as subway maps. To this end, physiological metrics obtained through eye tracking, task completion time, representative metric of task performance, and subjective evaluation metrics were used for the suitability evaluation of subway map designs. Results: In the result of gaze movement distance analysis, no significant difference was shown in the two design types in terms of a process finding a departure station from the starting point and a process finding a transfer station between the departure station and arrival station (destination). However, the gaze movement distance in the process finding the arrival station at the departure station was significantly shorter in the geographical type, rather than in the diagram type. The analysis of task completion time showed a result similar to the gaze movement distance analysis result. Task completion time was significantly shorter in the geographical type, rather than in the diagram type, which is in the process finding the arrival station at the departure station. In other information search processes, no significant difference was shown. As a result of subjective evaluation metrics analysis, no significant difference was revealed in the two design types. Conclusion: An analysis on the two representative subway map design types was carried out via the adoption of usability metrics. As a result, although no significant difference was shown in some information search processes, it was revealed that information search was easier in the geographical type overall. Also, it was found that usability metrics can be effectively used to evaluate the design types of subway maps. Application: The study results can be used to set design direction to offer ease in information search on subway lines. The study also can be used as a method to evaluate a subway map's design type.

Changes of Various Balls Velocity under the Different Surface Conditions after Impact (충돌 후 지면 조건에 따른 다양한 볼의 속도변화에 관한 연구)

  • Park, Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.91-97
    • /
    • 2007
  • The purpose of this study was to investigate the changes of various balls velocity under the different surface conditions after impact. For this study, four different balls were used which are golf ball, tang-tang ball, table tennis ball, and iron ball. And two different types of ground conditions were used which are artificial grass green and glass green. Movements of putter head and ball were recorded with 2 HD video cameras(60 Hz, 1/500s shutter speed). Small size control object($18.5cm{\times}18.5cm{\times}78.5cm$) was used in this study. To transfer the same amount of kinetic energy to the ball, pendulum putting machine was used. Analyzing the process of impact and the ball movement, a putter was digitized the whole movement but the ball was digizited within the 50cm movement. Velocities were calculated by the first central difference method(Hamill & Knutzen, 1995). Putter head velocities were about 112.2cm/s-116.2cm/s at impact. Maximum ball velocities were appeared 0.08s-0.10s after impact no matter what the ground conditions are. Table tennis ball recorded higher ball velocities than the other ball velocities and iron ball recorded the lowest ball velocity in this group. But Table tennis ball was influenced with the frictional force and immediately was decreased at the artificial grass green condition. If an object is received the kinetic energy under the static condition(v=0cm/s), the object recorded the maximum velocity shortly after the impact and then decreased the velocity because of the frictional force. The ball distance from the start position to the peak velocity position is about 6cm-10cm under the 112.2cm/s-116.2cm/s putting velocity with putter. 0.25 seconds later after impact balls were placed 40cm distance from the original position except iron ball. In this study, ball moving distances were too short therefore it was not possible to investigate the reactions after the translational force is disappeared. Rotational force would play a major role at the end of the ball movement. Future study must accept two things. One is long distance movement of ball and the other is balanced ground. Three-piece ball is a good item to investigate the golf ball movement on the different surface conditions.

A Quantitative Risk Analysis of LPG Leaked During Cylinder Delivery (가스용기 운반 중 누출된 LPG의 정량적 위험 분석)

  • Kim B-J,;Park Ki-Chang;Lee Kuen-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.2 s.19
    • /
    • pp.33-41
    • /
    • 2003
  • There exists high hazard when transporting LPG as well as using, storing, and producing. For small scale LPG consumer, retailers deliver LPG to customers via a truck loading many LPG cylinders. Suppose there occurred a accident during LPG cylinder transfer, this could result in serious damages to the life and properties in the near or neighbor of the accident spot. In this regard, we made a quantitative risk analysis to estimate the possible damages and the probability through the identification of accidents causes and the simulation of the possible scenario. In this study, we made the Excel & Visual Basic computer program to perform quantitative LPG accident analysis. The simulation showed the following results. In case of UVCE(Unconfined Vapor Cloud Explosion), the effect within l0m of the accident spot showed very severe structural damages and even the accident can break the window glasses of the area of 150 m apart from accident spot. In case of TNT corresponding probit analysis, after 10 minutes LPG leaking, $75\%$ window glasses of 40 m distance was expected to be broken. And $16\%$ frames of 20m distance, $10\%$ frames of 40m distance was expected to be collapsed.

  • PDF

In-Vivo Heat Transfer Measurement using Proton Resonance Frequency Method of Magnetic Resonance Imaging (자기 공명영상 시스템의 수소원자 공명 주파수법을 이용한 생체 내 열 전달 관찰)

  • 조지연;조종운;이현용;신운재;은충기;문치웅
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.172-180
    • /
    • 2003
  • The purpose of this study is to observe the heat transfer process in in-vivo human muscle based on Proton Resonance Frequency(PRF) method in Magnetic Resonance Imaging(MRI). MRI was obtained to measure the temperature variation according to the heat transfer in phantom and in-vivo human calf muscle. A phantom(2% agarose gel) was used in this experiment. MR temperature measurement was compared with the direct temperature measurement using a T-type thermocouple. After heating agarose gel to more than 5$0^{\circ}C$ in boiling hot water, raw data were acquired every 3 minutes during one hour cooling period for a phantom case. For human study heat was forced to deliver into volunteer's calf muscle using hot pack. Reference data were once acquired before a hot pack emits heat and raw data were acquired every 2 minutes during 30minutes. Acquired raw data were reconstructed to phase-difference images with reference image to observe the temperature change. Phase-difference of the phantom was linearly proportional to the temperature change in the range of 34.2$^{\circ}C$ and 50.2$^{\circ}C$. Temperature resolution was 0.0457 radian /$^{\circ}C$(0.0038 ppm/$^{\circ}C$) in phantom case. In vivo-case, mean phase-difference in near region from the hot pack is smaller than that in far region. Different temperature distribution was observed in proportion to a distance from heat source.

A Numerical Study for Calculation of Overall Heat Transfer Coefficient of Double Layers Covering and Insulation Material for Greenhouse (온실용 이중피복 및 보온재의 관류열전달계수 산정을 위한 수치적 연구)

  • Lee, Jong-Won;Kim, Dong-Keon;Lee, Hyun-Woo
    • Current Research on Agriculture and Life Sciences
    • /
    • v.33 no.2
    • /
    • pp.41-47
    • /
    • 2015
  • This study calculated the overall heat transfer coefficient (U-value) of greenhouse covering materials with thermal screens using a simulation model and then estimated the validity of the calculated results by comparison with measured values. The U-value decreased gradually as the thickness of the air space between the double glazing increased, and then remained essentially constant at thicknesses exceeding 25 mm. The U-value also increased with the difference in temperature between the inside and outside of the hot box. The vigorous convective heat transfer between two plastic films caused unsteady heat flow and then created a nonlinear temperature distribution in the air space. The distance did not affect the U-value at distances of 50~200 mm between the plastic covering and thermal curtain. The numerical calculation results, with and without sky radiation, were in accord with the experimental results for a $30^{\circ}C$ temperature difference between the inside and outside of the hot box. In conclusion, a reliable U-value can be calculated for a temperature difference of $30^{\circ}C$ or more between the inside and outside of the hot box.

Punching Shear Strength of the Void Transfer Plate (중공 전이 슬래브의 뚫림 전단 강도)

  • Han, Sang-Whan;Park, Jin-Ah;Kim, Jun-Sam;Im, Ju-Hyeuk;Park, Young-Mi
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.367-374
    • /
    • 2010
  • The transfer slab system is a structural system that transfers the loads from the upper shear wall structure to the lower columns. This is a costly system due to a very thick slab, and the relatively high cost can be mitigated by introducing voids in the slab. However, this system of flat plate containing voids is vulnerable to brittle failure caused by punching shear in vicinity of slab-column connection. Thus, the punching shear capacity of the void system is very important. However, the current code doesn't provide a clear design provision for the strength of slabs with a void section. In this study, experimental study was conducted to investigate the punching shear strength of the void slab system. The shear strength of the specimens was predicted by current code and previous researches. In result, the punching shear strength of the void system is determined as the least value calculated at critical section located a distance d/2 from the face of the column and the center of the void section using the effective area at critical section.

Tribological Characteristics of C/C-SiC-Cu Composite and Al/SiC Composite Materials under Various Contact Conditions (접촉 조건에 따른 C/C-SiC-Cu복합재와 Al/SiC복합재의 마모 특성에 관한 연구)

  • Kim, Byung-Kook;Shin, Dong-Gap;Kim, Chang-Lae;Goo, Byeong-Choon;Kim, Dae-Eun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.1
    • /
    • pp.21-30
    • /
    • 2017
  • The surface temperature of disc brakes varies during braking, which can affect the friction and wear behavior of braking systems. In order to develop an efficient braking system, the friction and wear behaviors of brake materials need to be clearly understood. In this work, the friction and wear behavior of the C/C-SiC-Cu composite and the Al/SiC composite, which are used in disc braking systems, were investigated. Both the surface temperature and contact pressure were studied. A pin-on-reciprocating tribotester was used for this purpose, in order to control temperature and load. Results showed that the friction varied significantly with temperature and sliding distance. It was found that a transfer layer of compacted wear debris formed on the wear track of the two materials. These layers caused the surface roughness of the wear track to increase. The outcome of this work is expected to serve as a basis for the development of braking systems under various operating conditions.