• Title/Summary/Keyword: Transfer Characteristics

Search Result 5,608, Processing Time 0.026 seconds

A study on the boiling heat transfer of R-113 in a horizontal tube (수평관내 R-113 냉매의 비등열전달에 관한 연구)

  • 최병철;김원녕;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.67-77
    • /
    • 1986
  • The information on the heat transfer characteristics, flow pattern and pressure drop, are very important for the desing of general heat exchanger, refrigerating system, air conditioning system and energy recovery system. In these systems, water or lubricating oil contained in working fluid affects greatly the flow and heat transfer condition and this phenomena must be considered in the practical design. An experiment has been performed for studying the flow and heat transfer characteristics of the forced convective horizontal flow of R-113 under the range of the liquid single phase state to the boiling flow state. Basic experimental results are obtained in the case that water or lubricating oil does not contaminate in the test fluid. Experimental results are as follows; (1) The local heat transfer coefficients in the nucleate boiling region and transition boiling region are almostly ten times as large as that of liquid single phase flow. (2) The measured heat transfer coefficient in the present experimental range is relatively agreed well with the predicted value from the various experimental results for the boiling flow.

  • PDF

Study on the Characteristics of Heat Transfer with Array of Multiple Impinging Jet Nozzle (충돌제트 노즐의 다중 배열 형상에 따른 열전달 특성)

  • Kim, D.K.;Son, J.D.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.32-37
    • /
    • 2006
  • In this paper, we present the flow and heat transfer characteristics with the array of impinging jet nozzles by using the numerical computation and experiment. Numerical solutions were obtained for dimensionless gap H=6, dimensionless outlet length L=10 and Reynolds number Re=1500 by using the commercial CFD code, CFX-5. Experimental and numerical results were agreed well with each other. It was found that the impinging jet with circular array nozzles generated the uniform heat transfer area and the maximum heat transfer is higher than rectangular array nozzles for certain parameter sets. It is one of the most important utilities providing steam to turbine in order to supply mechanical energy in thermal power plant. It is composed of thousands of tubes for high efficient heat transfer.

  • PDF

A Study on the Spray Cooling Characteristics according to the Angle of Hot Heat Transfer Surface (고온 열전달면의 각도에 따른 분무냉각 특성에 관한 연구)

  • Yoon, D.H.;Oh, C.;Yoon, S.H.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.320-327
    • /
    • 2002
  • An experimental study of heat transfer from hot flat surface to water sprays was conducted in high temperature region. Heat transfer measurements for hot flat surface were made by 4 sheathed C-A thermocouples. Droplets volume flux were also measured-independently at a position in spray field. The test conditions included variations in droplets volume flux, subcooling of cooling water of $1.565\times10^{-3} to 14.089\times10^{-3}m^3/m^2s and 80 to $20^{\circ}C$ respectively. The effects of inclination angle on heat transfer were investigated and changes in inclination angle of hot flat surface affected heat transfer coefficients of high temperature region.

Evaporating heat transfer characteristics of R-22 in small diameter tubes (세관 내 R-22 의 증발 전열 특성에 관한 연구)

  • 최영석
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.134-139
    • /
    • 2000
  • Evaporating heat transfer characteristics of R-22 were measured inside smooth horizontal copper tubes with inner diameters of 3.36 mm and 5.35 mm respectively. The experiments were conducted in the closed loop which was driven by a magnetic gear pump. Experiments were performed for the following range of variables ; mass velocity of refrigerants (200 to 400 $kg/m^2$ .s) saturation temperature ($0^{\circ}C, \; 5^{\circC$}) and quality (0 to 1.0) The main results obtained are as follows : Evaporating heat transfer coefficients in the small diameter tubes (ID<7 mm) were observed to be strongly affected by a variety of diameters and to differ from those in the large diameter tubes. The heat transfer coefficients of the small diameter tubes are higher than those of the large diameter tubes. Comparing the heat transfer coefficients between experimental results and some well-known previous predictions (Shah's correlation Gungor-Winterton's and Kandlikar's correlation) it was very difficult to apply those to small diameter tubes.

  • PDF

Study on Pressure Drop and Condensation Heat Transfer Characteristics of R-404A in Brazed Plate Heat Exchanger (R-404A를 사용한 용접형 판형 열교환기의 압력강하 및 응축 열전달특성에 관한 연구)

  • 권오갑;전창덕;강종식;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.174-183
    • /
    • 2001
  • Experimental study has been carried out on the characteristics of pressure drop and heat transfer of brazed plate heat exchangers using R-404A. Data are presented for the following range of variables: the mass flux ($20~80kg/m^2s$), chevron angle($20^{circ}C,\;35^{circ}C,\;45^{circ}C$) and inlet pressure of he refrigerant (1.4 and 1.6 MPa). for both subcooled and tow-phase flow, as chevron angle increases, pressure drop and heat transfer coefficient decrease. Condensation hat transfer coefficient and pressure drop was compared with the previously proposed correlations. Among them, Traviss correlation agreed with experimental results within -35~82% for heat transfer coefficient and -73~93% for pressure drop.

  • PDF

Numerical Analysis of Heat Transfer Characteristics in Corrugated Plate Type Heat Exchanger Channel (주름형상 판형열교환기 채녈에서의 열전달 특성 수치해석적 연구)

  • 김태용;이재용;김남진;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.588-594
    • /
    • 2001
  • The purpose of this study is to investigate the thermal and hydrodynamic characteristics of the channel in corrugated plate type heat exchangers numerically. Numerical work has been conducted using the Reynolds Stress Model(RSM) by utilizing the commercial finite-volume code, FLUENT. Based on this model, the dependence of heat transfer and friction factor on geometrical parameters have been investigated. It is found that larger corrugation angle give higher values of heat transfer coefficients and friction factors. As the reynolds number increases, the heat transfer coefficient also increases. It is also observed that the heat transfer coefficient reaches maximum while the friction factor stays relatively low at same corrugation angle. Through the analysis, it is found that the optimum corrugation angle for the heat exchanger performance exists. It is noted that the flow repulsions at the contact point of the two fluid streams make the low mixing more active for larger corrugation angle and high reynolds number.

  • PDF

Fluid Flow and Convective Heat Transfer Characteristics of Al2O3 Nanofluids (알루미나 나노유체의 유동 및 대류 열전달 특성)

  • Hwang, Kyo-Sik;Lee, Ji-Hwan;Lee, Byeong-Ho;Jang, Seok-Pil
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.1 s.256
    • /
    • pp.16-20
    • /
    • 2007
  • In this paper, convective heat transfer and flow characteristics of $Al_2O_3$ nanoparticles suspended in water flowing through uniformly heated tubes are experimentally investigated under laminar flow regime. The heat transfer coefficient and the pressure drop of nanoparticles suspended in water are experimentally presented according to the pumping power. In addition, the heat transfer coefficient and the pressure drop of $Al_2O_3$ nanoparticles suspended in water are compared with those of pure water under the fixed pumping power. It is shown that the heat transfer coefficient of $Al_2O_3$ nanofluids with 0.1% volume fraction is enhanced by about 12% although the increment of the pressure drop of those is 4% compared with those of pure water.

Development of a Particle Bed Heat Exchanger (IV) -An Experimental Study on Heat Transfer Characteristics of Fixed Bed Heat Exchanger (입자층(粒子層)을 이용(利用)한 열교환기(熱交換器) 개발(開發)에 관(關)한 연구(硏究)(IV) -고정층(固定層) 열교환기(熱交換器)의 전열특성(傳熱特性)에 대한 실험적(實驗的) 연구(硏究))

  • Yang, H.J.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.234-242
    • /
    • 1990
  • In this study, heat transfer characteristics of vertical fixed bed with air flowing through were experimentally investigated. The experiments were conducted for cases where heat was transfer steady state conditions from an immersed cylindrical heated to the surrounding fixed ved of steel balls. Based on the experimental data, the optimum conditions for heat transfer augmentation have been determined and shows in empirical forms. For the same power loss, comparison of heat transfer effect between the fixed bed and single phase forced convection device indicates that both miniaturization of heat exchange device and heat transfer augmentation at low flow velocity are possible by application of the fixed bed to heat exchangers. The present results could provide a useful design information for the heat exchangers where fixed beds are used.

  • PDF

An Investigation on Friction Factors and Heat Transfer Coefficients in a Rectangular Duct with Surface Roughness

  • Ahn, Soo-Whan;Son, Kang-Pil
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.549-556
    • /
    • 2002
  • An investigation on the fully developed heat transfer and friction factor characteristics has been made in rectangular ducts with one-side roughened by five different shapes. The effects of rib shape geometries as well as Reynolds numbers are examined. The rib height-to-duct hydraulic diameter, pitch-to-height ratio, and aspect ratio of channel width to height are fixed at e/De=0.0476, P/e=8, and W/H=2.33, respectively. To understand the characteristics of heat transfer enhancements, the friction factors are also measured. The data indicates that the triangular type rib has a substantially higher heat transfer performance than any other ones.

Heat Transfer Characteristics of Confined Slot Jet Impingement on a Flat Plate with Square Rods (사각봉이 배열된 슬롯제트 충돌면에서의 열전달 특성)

  • Chung, In-Kee;Park, Si-Woo
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.119-124
    • /
    • 2000
  • The heat transfer characteristics of confined turbulent slot jet impingement on the flat plate with square rods(turbulence promoter) have been experimentally investigated. The effects of jet Reynolds number (Re=3900, 5800, 7800, 9700), dimensionless slot-to-plate distance(H/B=4, 6, 8) clearance(c) between square rods and the plate, and the length(d) of a side of the square rod were examined. Measurement or heat transfer rate were conducted using naphthalene sublimation technique. When square rods were inserted over the heat transfer surface, heat transfer rate was slightly increased in the wall jet region.

  • PDF