• Title/Summary/Keyword: Train voltage

Search Result 231, Processing Time 0.021 seconds

A Study on Motor Block Measurement of Railway Vehicle (철도차량 Motor Block 측정에 관한 연구)

  • Han, Young-Jae;Kim, Ki-Hwan;Lee, Su-Gil;Baek, Kwaug-Sun;Chung, Eun-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1291-1293
    • /
    • 2003
  • The korean high speed train (350km/h), composed of 7cars that are 2 power cars, 2 motorized car and 3 trailer cars, has been developed and is under on-line test. To verify the design requirements about the functions and traction performances of this train, KRRI(Korea Railroad Research Institute) decided to evaluate traction performances of the train during on-line test. For this purpose, such as torque, velocity, voltage and current, must be measured. KRRI has developed the measurement system that can be measured vast and various signals effectively. In this paper, we introduce traction performances of korean high speed train. The traction measurement items are focused on the verification of motor block performances. Motor block are consist of 2 motor. For this test, we verified traction performances of korean high speed train.

  • PDF

The analysis of power quality characteristics in high speed train through neutral section of catenary system (절연구간운행 고속철도차량 전력품질 특성 분석)

  • Hong, Hyun-Pyo;Choi, Eui-Seong;Lee, See-Bin;Lee, Hee-Soon
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.634-643
    • /
    • 2011
  • The neutral section was installed in order to prevent conflict with different phase angle source in electric railway catenary system. The speed of electric train reduced due to coasting operation by notch off when it passed the neutral section. And, the catenary wire was damaged and the accident might be happened because of the arc generation when the electric train passed the neutral section with notch off condition. The inrush current of main transformer installed tiling train is analyzed during the operation of MCB(main circuit break) passing through the neutral section. The instantaneous waveform of load current were analyzed in case of powering and regenerative braking. Inrush current waveform with run of AC railway train showed that inrush current waveform and harmonics, the inrush current generated from main transformer in train has bad effects on power quality problem. In order to reduce these inrush currents, the MCB is connected when the phase angle of voltage is 90 degree. This paper is to measure inrush current and harmonics in main transformer of high speed train in neutral section of electric railway. This measurement report is used to control minimum inrush current in algorithm and power phase angle.

  • PDF

Comparison and analysis of control algorithms of single-phase AC/DC parallel converters (단상 AC/DC 병렬 컨버터 제어 알고리즘의 비교, 분석)

  • 이강희
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.290-293
    • /
    • 2000
  • In this paper the algorithm which controls output voltage and power factor independently and the algorithm which controls output voltage with fixed unity power factor are compared and analyzed. These algorithms are applied to single-phase AC/DC parallel are applied to single-phase AC/DC parallel converters for a high speed train system. The control characteristic of the algorithms are compared and analyzed with respect to the output voltage and input power factor when system parameters vary.

  • PDF

A Study of Electrical Characteristics for ZnO Varistor in HST (전철용 ZnO 바리스타(IEC 10kA)의 전기적 특성 연구)

  • Hwang, M.K.;Youn, B.H.;Huh, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1519-1521
    • /
    • 1998
  • A Gapless HST(high speed train) arrester design is not possible without the highly non-linear ZnO(ZincOxide) varistors. Zno varistors combine excellent protective characteristics with steady state performance to maximize protection, the ZnO varistors are selected for each unit based on leakage current and residual voltage, to verify that the residual voltage is the residual voltage published for HST arrester.

  • PDF

An Optimal PWM Strategy for IGBT-based Traction Inverters - (철도용 IGBT인버터를 위한 최적 PWM기법)

  • 황재규;김영민;장기호
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.442-449
    • /
    • 1998
  • Since it is essential for traction motors to reduce size and weight to achieve given traction effort, they need high input voltage. But the lack of input voltage occurs periodically due to the characteristics of train system. Therefore traction inverters use over-modulation PWM to maximize inverter's voltage gain. On the other hand, IGBT inverters can use higher frequency twice than GTO ones, which resulted in the need for novel optimal synchronous PWM strategy. This paper suggests that linearly-compensated overmodulation/optimal synchronous PWM strategy and also the simulation results of the method for a real traction motor-intertia model are presented.

  • PDF

A Study on Overall Measurement System Development of Tilting Train Express (틸팅차량 종합계측시스템 개발에 관한 연구)

  • Han, Young-Jae;Kim, Sang-Soo;Kim, Young-Guk;Koo, Hun-Mo;Kim, Seog-Won
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.6 s.37
    • /
    • pp.671-676
    • /
    • 2006
  • A measurement system was developed in this study. It conducts on-line testing and evaluation of tilting train express(TTX). The measurement system is installed in each train for the performance measurement during the test run. It is composed of software part, hardware part and can measure various signals such as vehicle velocity, catenary voltage, motor temperature. The software controls the hardware of the measurement system, performs the analysis and calculation of measurement data and acts as interface between users and the system hardware. The hardware is consisted of 7 DAMs(Data Acquisition Modules) and 6 monitoring modules.

Development of the Traction Motor for High Speed Train (한국형 고속전철용 견인전동기 개발)

  • 이상우;윤종학;최종묵;박계서
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.427-433
    • /
    • 2002
  • An inverter-driven induction motor is usually adapted to the traction motor for a high speed drive system requiring safety, reliability, performance, compact size owing to the space and weight alloted for attaching to train, etc. and AC Traction motor for G7 train will be operated in the worst condition such as mechanical vibration, limited mounting space, severe thermal stress, inverter with non-sinusoidal voltage waveform, dust and so on. therefore, design procedure must be carefully carried out wi th considering the motor size, vibration and thermal expansion of rotor bars, insulation system, reliability of frame, as well as output characteristics. In this paper, we will inform the characteristics and design of the traction motor for G7 train and also analyze the test result of it.

  • PDF

A Study on an arc according to loss of contact between pantograph and catenary (판토그래프와 전차선 사이에서 발생되는 아크 특성에 관한 연구)

  • Lee, Bong-Yi;Kim, Jae-Chul;Han, Sung-Ho;Lee, Su-Gil
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.367-370
    • /
    • 2005
  • Electric train is currently used widely, and much development is expected. But, in case of electric train, as comparison with diesel rolling stock, many electrical problem such as harmonic, voltage sag, EMI, EMC usually occur. Accordingly, in order to popularize an electric train, first, a study on electrical problem at an electric train must be accomplished. In this paper, one of electrical problems, arc characteristics according to loss of contact between pantograph and catenary was analyzed.

  • PDF

Power System Simulation in Seoul matropolitain subway Line-6 system (서울 지하철 6호선에 대한 전력계통 시뮬레이션)

  • Lee, Tae-Shik;Moon, Young-Hyun;Sung, Soo-Young;Yoon, Kap-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.137-139
    • /
    • 1993
  • This paper details methods used to verify the adquacy of a dc traction power supply for design in Seoul matropolitain subway Line-6 system. Examples of the approach are given for a major subway presently under construction. The performance of trains operating at maximum system design capacity is modelled using a train simulation program. Using a dc network analyser program, the maximum train operating timetable, and a model of the ac and dc electrical suppy system, the electrical performance of the entire system can be modelled over a 24-hour period. The results of this analysis are used to determime: train voltage at a level sufficient to ensure train schedules: adequacy of traction transformers, rectifier, and switchgear ratings; sizes of the overhead contact systern conductors, and ac and de feeder cables: and power and energy demands at the utility company's supply points for inital and final timetable operations.

  • PDF

Analysis of the Effects of SD Plasma on Aerodynamic Drag Reduction of a High-speed Train

  • Lee, Hyung-Woo;Kwon, Hyeok-Bin
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1712-1718
    • /
    • 2014
  • Experimental analysis according to the plasma actuator design variables was performed in order to verify the effects of sliding discharge plasma on aerodynamic drag reduction of a high-speed train. For the study, sliding discharge plasma actuator and high-frequency, high-voltage power supply were developed and experimented to figure out the best design variables for highest ionic wind velocity which could reduce the drag force. And then, 5% reduced-scale model of a high-speed train was built for wind tunnel test to verify it. From the results, it was confirmed that sliding discharge plasma had contribution to reduce the drag force and it had the potential to be applied to real-scale trains.