Effect on the Characteristics and Control Performance due to the Ventilation Hole Design of the Traction Motor (냉각 통풍홀 설계로 인한 견인 전동기 특성 및 제어 성능 영향 연구)

  • Kim, Ki-Chan;Lee, Jeong-Il;Kwon, Jung-Lock
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.801-803
    • /
    • 2001
  • On this study the motor design method with fairly good characteristics and control capability as well as cooling capability is presented with considering the magnetic effect due to ventilation hole, which is installed to prevent the temperature rise. When the input voltage rises due to critical variation in traction power supply system, the final ventilation hole is presented by checking the inductance parameter with clarifying the relation between saturation of the motor core and the ventilation hole.

  • PDF

Voltage Unbalance Evaluation in Autotransformer-Fed Electric Railway Systems using Circuit Analysis (회로해석을 이용한 전기철도 급전시스템의 전압불평형 평가)

  • 오광해;차준민
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.20-28
    • /
    • 1998
  • This study proposes a new method to estimate voltage unbalance more exactly using Thevenin's equivalent circuit. The conventional simple formula were easily applied to evaluate voltage unbalance. Because the formula was derived on the assumption that traction load would be directly connected to the secondary windings of the main transformer, they could not consider the detailed characteristics of traction power supply system, for example, self and mutual impedances of rail, catenary and return feeder. So, the ac쳐racy of the results could not be guaranteed. The proposed algorithm is applied to a standard autotransformer-fed test system to analyze unbalance phenomena. Through simulations, we could evaluate voltage and current unbalance factors and compare the voltage unbalance of the three transformer connection schemes : single phase, V- and Scott-connections which are required for suitable train operation schedules. Additionally, we could determine the combinations of trains which can be operated under the unbalance factor limits.

  • PDF

A Study on the Power Factor Improvement of DC Power Regenerating Systems (직류전력 회생시스템의 역률개선에 관한 연구)

  • 김경원;윤인식;서영민;윤덕용;홍순찬
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.410-415
    • /
    • 2001
  • This paper proposes a new control scheme for the power factor improvement of DC power regenerating systems, which can regenerate the excessive DC power from DC bus line to AC supply in substations for traction systems. From the viewpoint of both power capacity and switching losses, the system is designed on the basis of three-phase square-wave inverters and composed of two inverters, zig-zag connected output transformers, and an AC filter. The output voltages of the regenerating system are not sinusoidal. However, regenerated complex power is analyzed on the basis of fundamental components and thus the reactive power produced by harmonics is not considered. Therefore, it is needed a new control scheme capable of controlling the reactive power nearly to zero even for nonsinusoidal cases. To verify the validity of the proposed control scheme, computer simulations are carried out. And the results show that the power factor is theoretically higher than 0.99.

  • PDF

Inband Signaling on the Control Pilot of Electric Vehicle Supply Equipment (전기자동차 충전스탠드의 제어파일럿 신호를 이용한 대역 내 통신 방식)

  • Kim, Chul-Woo;Kim, Sang-Beom;Lim, You-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2019-2020
    • /
    • 2011
  • Electric Vehicle Supply Equipment(EVSE) is a system or an equipment to supply electric power for charging the traction batteries on the electric vehicle. Control Pilot is an electric signal generated by EVSE and is transmitted to the electric vehicle by a vehicle coupler and a contact. The duty cycle of control pilot determines the maximum current to be drawn by electric vehicle. When the duty cycle is 5%, it is indicated that digital communication is needed. This paper deals with the data format and definition about communication scheduling through the inband signal on the control pilot of EVSE.

  • PDF

New Method to Quantify the Operation Condition for Zone 3 Impedance Relays during Low-Frequency Power Swings

  • Li, Shenghu
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.29-35
    • /
    • 2008
  • With long time setting, zone 3 impedance relays are considered insensitive to power swings, and their operation condition during power swings is seldom analyzed. Instead of ti me-consuming simulation to the swing loci, their operation condition is directly quantified by polynominal functions in this paper to find the critical swing angle and frequency for relay operation under different relay settings and system parameters. It is found: (1) the swing loci are more densely populated inside than outside of the protection region, which corresponds to long residence time and possible relay operations; (2) the relays may be sensitive to load encroac hments and stable power swings with different relay settings and system parameters; (3) the critical swing frequency may be in the range of low-frequency power swings.

Analysis of Voltage Drop under Extended Feeding in KyungBu High Speed Line (I) (경부고속선의 전력공급 안정성 검토를 위한 연장급전 조건의 전압강하 검토 (I))

  • Kim, Joo-Rak;Lee, Chang-Mu;Jang, Dong-Uk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1432-1438
    • /
    • 2011
  • This paper presents the simulation of traction power supply system for the evaluation of voltage drop in Kyungbu high speed line. This simulation is performed in circumstance of extended feeding through vicinity substation. Extended feeding should be considered from design of system. Therefore, voltage drop at extended feeding must be accepted against regulation. In this paper, voltage drop is evaluated under condition of extended feeding targeting section from Shinchungju and Pyungtaek S/S.

  • PDF

Simulator of Automatic Power Switching System (절연구간 자동절체 통과 현상 규명용 모의시뮬레이터 제작)

  • Han, Moon-Seob;Shin, Hyo-Bum;Jang, Dong-Uk
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.918-923
    • /
    • 2011
  • On AC railway systems, the neutral sections are installed in front of substations and sectioning posts in order to avoid crash between power that have differing phases. In case railway vehicles pass through these neutral sections, it is necessary for them to switch to coasting driving by notch-off. This may reduce speed of the vehicles, resulting lowered train operation efficiency. The usage of automatic power switching systems makes it possible to pass neutral sections at notch-on, enhancing operation efficiency so that it is appropriate for high-speed railway applications. This paper introduces a simulator that assesses efficiency of automatic power switching systems in neutral sections. The is composed of a power supply system, electric railway vehicles, thyristor switches, and traction motors.

  • PDF

A Study on Ripple Current Reduction of Interleaved Bi-directional DC-DC Converter for Traction Characteristic of Railway Vehicle (철도차량 견인특성을 고려한 인터리브드 양방향 DC-DC 컨버터의 리플전류 저감에 관한 연구)

  • Lee, Hwan;Jung, No-Geon;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.4
    • /
    • pp.733-739
    • /
    • 2017
  • Research on fuel cell systems attracting attention as an environmentally friendly energy source has been actively conducted. And research is being conducted on railway vehicles that use direct current power generated by a fuel cell as an energy source. In this paper, a two-phase interleaved bidirectional DC-DC converter has been proposed which can supply electric energy of a battery to a traction motor during powering and charge the battery with regenerative energy during braking. Therefore, the topology of the energy storage system applied to the railway vehicle was analyzed, and the simulation was performed by constructing the power conversion system by this topology. Experiments were also conducted through hardware design and fabrication based on the simulation analysis results, and the validity of the hardware implementation was verified.

A Study on the Supply and Stray Current Distribution of the DC Railway Power System (직류전기철도 급전시스템에서 공급 및 누설전류 분포에 관한 연구)

  • Cho, Woong-Ki;Choi, Kyu-Hyoung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.160-168
    • /
    • 2010
  • This paper presents the analysis of the current as stray current and supplied current of the substation, on the DC railway power system. In DC railway power supply system, the running rails are usually used as the return conductor(negative-polarity) for traction load current. This condition mainly focuses on economic considerations, since it does not require the installation of an additional return conductor. But, problems of low resistance between the running rails for the return conductor and earth allows a significant part of the return load current to leak into the earth. This current is normally called to as leakage or stary current. This stary currents creates serious problems for any electrified matter in the underground. Therefore, reduction of stray current of the DC railway power supply system is also of direct benefit to the operational and safety aspects of the DC railway systems. In this paper, deal with the analysis of the current distribution on the DC railway power system applied the common grounding system, using SPLIT of CDEGS program.

The Development of Equalizing Spacer for Minimization of Voltage Drop according to DC Feeder Extension (직류 급전선 증설에 따른 전압강하 최소화를 위한 균압 스페이서 개발)

  • Lee, Jae-Bong;Seo, Il-Kwon;Na, Youn-Il;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.1013-1018
    • /
    • 2014
  • This paper described the development of equalizing spacer for minimization of voltage drop according to DC feeder extension. Power consumption is increased as shorter interval of train driving time and transportation capacity increase in urban subway. Therefore we investigated voltage drop of catenary at a point in case of traction driving of a train in parallel to the DC power supply system. Based on it's result, equalizing spacer is designed and fabrication to minimize the voltage drop in accordance with the power supply line arranged in three rows, and then its performance was confirmed that the stress distribution of main body and the distributed load are satisfied through the body structure modeling.