Browse > Article
http://dx.doi.org/10.5370/JEET.2008.3.1.029

New Method to Quantify the Operation Condition for Zone 3 Impedance Relays during Low-Frequency Power Swings  

Li, Shenghu (School of Electrical Engineering and its Automation, Hefei University of Technology, China)
Publication Information
Journal of Electrical Engineering and Technology / v.3, no.1, 2008 , pp. 29-35 More about this Journal
Abstract
With long time setting, zone 3 impedance relays are considered insensitive to power swings, and their operation condition during power swings is seldom analyzed. Instead of ti me-consuming simulation to the swing loci, their operation condition is directly quantified by polynominal functions in this paper to find the critical swing angle and frequency for relay operation under different relay settings and system parameters. It is found: (1) the swing loci are more densely populated inside than outside of the protection region, which corresponds to long residence time and possible relay operations; (2) the relays may be sensitive to load encroac hments and stable power swings with different relay settings and system parameters; (3) the critical swing frequency may be in the range of low-frequency power swings.
Keywords
Load modeling; Parameter; Traction power supply system;
Citations & Related Records
연도 인용수 순위
  • Reference
1 J. He, Y. Li, B. Li, Z. Guo, and X. Dong, 'Relay protection for UHV transmission lines, part II disposition of relay protection', Automation of Electric Power Syst., vol. 26, no. 24, pp. 1-6, Dec. 2002
2 AREVA-TD, PRAG Network Protection & Automation Guide. Online. Available: http://www. areva-td.com
3 G. Gangadharan and A. Anbalagan, 'Microprocessor based three step quadrilateral distance relay for the protection of EHV/UHV transmission line', IEEE Trans. Power Del., vol. 7, no. 1, pp. 91-97, Jan. 1992   DOI   ScienceOn
4 S. Li, N. Yorino, and Y. Zoka, 'Operation margin analysis of zone 3 impedance relay based on sensitivities to power injection', IET Gener. Transm. and Distrib., vol. 1, no. 2, pp. 312-317, Mar. 2007   DOI   ScienceOn
5 NERC. (2005). Working Paper on a Proposed Transmission Relay Loadability Standard. Online. Available: http://www.nerc.com
6 D. Tziouvaras. Relay Performance during Major System Disturbances. Online. Available: www.selinc. com
7 S. Li and M. Ding, 'The vulnerability analysis of transmission system based on the performance of mho relay and SVC', Int. J. Emerging Electric Power Syst., vol. 8, no. 1, 1-15, 2007
8 M. Klein, G.J. Rogers, and P. Kundur, 'A fundamental study of inter-area oscillations in power systems', IEEE Trans. Power Syst., vol. 6, no. 3, pp. 914-921, Aug. 1991   DOI   ScienceOn
9 B. Yu, J. Sun, S. Tang, X. Wu, and H. Liang, 'Analysis of low frequency oscillation in Hubei electric power system', Automation of Electric Power Syst., vol. 25, no. 15, pp. 39-42, Aug. 2001
10 S.H. Horowitz and A.G. Phadke, 'Third zone revisited', IEEE Trans. Power Del., vol. 21, no. 1, pp. 23-29, Jan. 2006   DOI   ScienceOn
11 IEEE PSRC. (2005). Power Swing and Out-of-Step Considerations on Transmission Lines. Online. Available: http://www.pes-psrc.org
12 S. Li, N. Yorino, and Y. Zoka, 'Controllability analysis for operation margin of zone 3 impedance relay', IEEJ Trans. Power and Energy, vol. 127, no. 3, 502-506, Mar. 2007   DOI   ScienceOn
13 D.N. Kosterev, C.W. Taylor, and W.A. Mittelstadt, 'Model validation for the August 10, 1996 WSCC system outage', IEEE Trans. Power Syst., vol. 14, no. 3, pp. 967-979, Aug. 1999   DOI   ScienceOn
14 A. Mechraoui and D. W. P. Thomas, 'A new blocking principle with phase and earth fault detection during fast power swings for distance protection', IEEE Trans. Power Del., vol. 10, no. .3, pp. 1242-1248, July 1995   DOI   ScienceOn
15 L. Zou, Q. Zhao, X. Lin, and P. Liu, 'Improved phase selector for unbalanced faults during power swings using morphological technique', IEEE Trans. Power Del., vol. 21, no. 4, pp. 1847-1855, Oct. 2006   DOI   ScienceOn