• Title/Summary/Keyword: Tracker system

Search Result 291, Processing Time 0.026 seconds

SELECTION OF DESIGN PARAMETERS IN OPTICAL SYSTEM OF STAR TRACKER FOR A SATELLITE (위성용 STAR TRACKER 광학계의 설계요소 선정)

  • Nah, Ja-Kyung;Kim, Yong-Ha;Yi, Yu
    • Journal of Astronomy and Space Sciences
    • /
    • v.16 no.2
    • /
    • pp.273-284
    • /
    • 1999
  • In order to develop star trackers for a satellite in our country we studies selection procedure of optical parameters. For logical selection of the optical parameters, we simulated the entire processes in which star lights imaged on a CCD sensor were read into and processed in an associated electronics. The simulation resulted in relations between star's magnitude and achievable pointing accuracy, from which we derived optimal optical parameters to satisfy a required pointing accuracy of a star tracker. The selected optical parameters were used in an optical system design of a star tracker with a pointing accuracy of 10 arcsec.

  • PDF

On the user equipment (UE) side time tracker design and implementation of the WCDMA system (WCDMA 시스템의 단말기측 time tracker 설계 및 구현)

  • Yeh, Choong-Il;Chang, Kyung-Hi;Kim, Hwan-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.2A
    • /
    • pp.96-101
    • /
    • 2003
  • This paper is on the user equipment (UE) side time tracker design and implementation of the wideband code division multiple access (WCDMA) system. The time tracker is constructed as a second order closed loop including time error detector (TED), loop filter (LP), numerically controlled oscillator (NCO), and sample selector (SS). Through the simulation, we found the gain of the TED as a function of the CPICH power contribution to the total transmission power of the base station. Also we derived the transfer function of the loop and the BER versus DPCH power relationships where timing offsets and loop noise bandwidths are used as parameters. In the curve, we can conclude that there are appropriate loop noise bandwidths according to the given environments for the better performance.

Accuracy Verification of Optical Tracking System for the Maxillary Displacement Estimation by Using of Triangulation (삼각측량기법을 이용한 광학추적장치의 상악골 변위 계측에 대한 정확성 검증)

  • Kyung, Kyu-Young;Kim, Soung-Min;Lee, Jong-Ho;Myoung, Hoon;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.41-52
    • /
    • 2012
  • Purpose: Triangulation is the process of determining the location of a point by measuring angles to it from known points at either end of a fixed baseline. This point can be fixed as the third point of a triangle with one known side and two known angles. The aim of this study was to find a clinically adaptable method for applying an optical tracking navigation system to orthognathic surgery and to estimate its accuracy of measuring the bone displacement by use of triangulation methods. Methods: In orthognathic surgery, the head position is not fixed as in neurosurgery, so that a head tracker is needed to establish the reference point on the head surface byusing an optical tracking system. However, the operation field is interfered by its bulkiness that makes its clinical use difficult. To solve this problem, we designed a method using an Aquaplast splinting material and a mini-screw in applying a head tracker on a patient's forehead. After that, we estimated the accuracy of measuring displacements of the ball marker by an optical tracking system with a conventional head tracker (Group A) and with a newly designed head tracker (Group B). Measured values of ball markers' displacements by each optical tracking system were compared with values obtained from fusion CT images for an estimation of accuracy. Results: The accuracy of the optical tracking system with a conventional head tracker (Group A) is not suitable for clinical usage. Measured and predictable errors are larger than 10 mm. The optical tracking system with a newly designed head tracker (Group B) shows 1.59 mm, 6.34 mm, and 9.52 mm errorsin threeclinical cases. Conclusion: Most errors were brought on mainly from a lack of reproducibility of the head tracker position. The accuracy of the optical tracking system with a newly designed head tracker can be a useful method in further orthognathic navigation surgery even though the average error is higher than 2.0 mm.

Developing Head/Eye Tracking System and Sync Verification (헤드/아이 통합 트랙커 개발 및 통합 성능 검증)

  • Kim, Jeong-Ho;Lee, Dae-Woo;Heo, Se-Jong;Park, Chan-Gook;Baek, Kwang-Yul;Bang, Hyo-Choong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.1
    • /
    • pp.90-95
    • /
    • 2010
  • This paper describes the development of integrated head and eye tracker system. Vision based head tracker is performed and it has 7mm error in 300mm translation. The epi-polar method and point matching are used for determining a position of head and rotational degree. High brightness LEDs are installed on helmet and the installed pattern is very important to match the points of stereo system. Eye tracker also uses LED for constant illumination. A Position of gazed object(3m distance) is determined by pupil tracking and eye tracker has 1~5 pixel error. Integration of result data of each tracking system is important. RS-232C communication is applied to integrated system and triggering signal is used for synchronization.

Sun point detector for daylight system (태양광조명장치용 고정밀 태양위치 검출시스템)

  • Kim, Sun Ho;Kim, Byung Cheol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.4
    • /
    • pp.26-31
    • /
    • 2010
  • Finding sufficient supplies of clean energy for future is one of the society's most important challenges according to technologies. Alternative renewable energy source such as solar energy can be substituted for exceeding human energy need. The main factor affect to solar performance is a collective intensity. To enhance intensity, suitable equipment is a solar tracker. The solar tracker consists of sun point detector module, mechanical mechanism module with actuator and control system module. This paper presents sun point detector for solar tracker of daylight system. To evaluate the detecting accuracy, an experimental device is implemented. In experimental results, the accuracy of development system has under 0.11%/0.5deg.

Realization of automatic video tracker using ASIC (ASIC을 이용한 자동영상 추적기 구현)

  • 강재열;윤상로
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.8
    • /
    • pp.1885-1896
    • /
    • 1996
  • This paper describes the implementation of the AVT(Automatic video Tracker) using ASIC. The basic tracking algorithm is based on the spatio-temporal gradient method, and adaptive window sizing, track state decision algorithm were also realized. Newly developed ASIC performs recursive image filtering, extraction of spatio-temporal gradient/gradient functions of image in field rate. Using the FPGA/ASIC, the tracker was simply realized in one board type which can be easily applied to various image system. We conformed ASIC operation by computer simulation and tested the system in real tracking situations. From the result, the system can track the moving target which has a velocity of 2-3 pixel/field and a size of varying from 2 to 128 pixes. Also fast refresh rateof motion estimation(60Hz) improves the characteristics of servoing system which forms feedback loop with the tracker.

  • PDF

Real-Time Apartment Building Detection and Tracking with AdaBoost Procedure and Motion-Adjusted Tracker

  • Hu, Yi;Jang, Dae-Sik;Park, Jeong-Ho;Cho, Seong-Ik;Lee, Chang-Woo
    • ETRI Journal
    • /
    • v.30 no.2
    • /
    • pp.338-340
    • /
    • 2008
  • In this letter, we propose a novel approach to detecting and tracking apartment buildings for the development of a video-based navigation system that provides augmented reality representation of guidance information on live video sequences. For this, we propose a building detector and tracker. The detector is based on the AdaBoost classifier followed by hierarchical clustering. The classifier uses modified Haar-like features as the primitives. The tracker is a motion-adjusted tracker based on pyramid implementation of the Lukas-Kanade tracker, which periodically confirms and consistently adjusts the tracking region. Experiments show that the proposed approach yields robust and reliable results and is far superior to conventional approaches.

  • PDF

Scalar Adaptive Kalman Filtering for Stellar Inertia! Attitude Determination

  • Jung, Jae-Woo;Cho, Yun-Cheol;Bang, Hyo-Choong;Tahk, Min-Jea
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.3 no.2
    • /
    • pp.88-94
    • /
    • 2002
  • This paper describes attitude determination algorithm for the low earth orbit(LEO) spacecraft using stellar inertial sensors. The cascaded gyro/star tracker extended Kalman filter is constructed to fuse two sensor data. And then the smoothing of the measurement are proposed for an unreasonable jump of star tracker. The smoothing algorithm for the rejection of star tracker error jumps is designed by scalar adaptive filter. The proposed algorithms operate to process the measurement of gyro/star tracker Kalman filter, therefore, it is comparatively simple to apply these methods to other integration systems. Simulations to gyro/star tracker integrated system show that the proposed method is effective.

Tracking System for Optimum Solar Power System of Widely Separated Cave (고립원격지 동굴 전원용 태양광발전 광 추적 시스템)

  • Suh, Oh-Ji;Soh, Dea-Wha
    • Journal of the Speleological Society of Korea
    • /
    • no.89
    • /
    • pp.27-33
    • /
    • 2008
  • Solar energy is most green and clean, unlimited and sustainable energy source on the earth. It is almost 97% of imported consumer energy in Korea. Because of resource poor nation, it is necessary to do their best to make alternative energy to allot their deficiency of the matter in hand of energy resources of petroleum. In a point of view of this problems, the natural solar energy should be improved by any methods as much, possible as we need. Photovoltaic generation with solar tracking system for obtaining optimal power is one of most benefit equipment to improve power of solar-cell panel producing clean electric power efficiently. Solar tracker is a device for orienting a solar photovoltaic panel toward the sun perpendicularly to sunlight, especially in widely separated place. For this reason, we are very interested in developing the equipment system of tracker, specially in solar cell applications, obtaining a high degree of accuracy to ensure that the optimal sunlight could be directed precisely against to the powered device. As a result, it was obtained of 12.46 volts at 90$^\circ$toward solar panel and 9.44 volts at 45$^\circ$, furthermore, improved efficiency more than 30% of average output voltage between tracker system (12.41V) and fixed system (8.55V), respectively. It is also very useful for optimum power system of widely separated cave.

Implementation of the multi-target tracker for MIROSOT

  • In, Chu-Sik;Choi, Yong-Hee;Lee, Ja-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.828-831
    • /
    • 1997
  • One of the most important design factor for the image tracker is the speed of the data processing which allows real-time operation of the system and provides reasonably accurate performance at the same time. Use of powerful DSP alone does not guarantee to meet such requirement. In this paper, a simple efficient algorithm for real-time multi-target image tracking is suggested. The suggested method is based on a recursive centroiding technique and color table look-up. This method has been successfully implemented in a image processing system for Micro-Robot Soccer Tournament(MIROSOT). This tracker can track positions of a ball, 3 enemies, and 3 agents at the same time. The experimental results show that the processing time for each frame of image is less than 7ms, which is well within the 60Hz sampling interval for real-time operation.

  • PDF