• 제목/요약/키워드: Track Component

검색결과 151건 처리시간 0.025초

탑재형 냉동기를 이용한 고온 초전도 모터 개발 및 회전 실험 (Development and rotating test of the high temperature superconducting motor with on-board cryocooler)

  • 기태경;김영권;김희선;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권1호
    • /
    • pp.12-16
    • /
    • 2011
  • In this paper, the prototype of the HTS motor with an on-board cryocooler, is fabricated and tested. The overall system is composed of the stator with conventional copper winding, the rotor with superconductor, and the rotating cryocooler designed from the on-board concept. The rotor is fabricated as the race-track coil with 2G, YBCO tape and contacts with the on-board cryocooler while being rotated together. An inline-type pulse tube refrigerator is used as the on-board cryocooler. The cryocooler is fabricated from optimal process to satisfy the structure and thermal stability of the on-board system. Each component is integrated according to carefully defined sequence. Specially, a combining method of torque tubes is an important part for sustaining stability of the rotor and the cryocooler. In the rotating test, the HTS motor is successfully operated with 240 rpm of rotating speed when 75 A current is supplied to the superconducting rotor. In this paper, potential problems of the HTS motor system using the on-board cryocooler are proposed and solved, and realistic possibility of this concept is also confirmed.

도서관 정보코먼스에서 러닝코먼스로의 진화 - 일본 공공도서관의 러닝코먼스화 사례를 중심으로 - (Evolution of Public Library from Information Commons to Learning Commons - The Cases of Japan Public Library -)

  • 임형연
    • 한국도서관정보학회지
    • /
    • 제45권3호
    • /
    • pp.441-462
    • /
    • 2014
  • 본 연구는 최근 문헌정보학에 대두되고 있는 정보코먼스 및 러닝코먼스에 대한 개념과 차이점을 분석하고 일본 공공도서관의 러닝코먼스화 사례연구를 통하여 공공도서관의 러닝코먼스화 방향에 관한 시사점을 얻고자 하였다. 러닝코먼스화 분석을 위해 러닝코먼스의 구성요소를 이론적으로 정리해보고, 공공도서관에 적합한 분석의 틀을 설계하고 일본의 공공도서관에 대한 사례분석을 실시하였다. 사례 분석의 결과, 도서관이 정보의 도구에 의해 주도된 정보 코먼스를 넘어 본연의 학습기능으로 돌아가고 있음을 보여주고 있다. 또한 러닝코먼스를 지향하는 공공도서관이 해야 할 미래 과제에 대한 시사점을 던져주고 있다.

비정현 계통 전압하에서 단상 인버터의 PLL 성능 개선 방법 (A Method to Improve the Performance of Phase-Locked Loop (PLL) for a Single-Phase Inverter Under the Non-Sinusoidal Grid Voltage Conditions)

  • 칸 레이안;최우진
    • 전력전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.231-239
    • /
    • 2018
  • The phase-locked loop (PLL) is widely used in grid-tie inverter applications to achieve a synchronization between the inverter and the grid. However, its performance deteriorates when the grid voltage is not purely sinusoidal due to the harmonics and the frequency deviation. Therefore, a high-performance PLL must be designed for single-phase inverter applications to guarantee the quality of the inverter output. This paper proposes a simple method that can improve the performance of the PLL for the single-phase inverter under a non-sinusoidal grid voltage condition. The proposed PLL can accurately estimate the fundamental frequency and theta component of the grid voltage even in the presence of harmonic components. In addition, its transient response is fast enough to track a grid voltage within two cycles of the fundamental frequency. The effectiveness of the proposed PLL is confirmed through the PSIM simulation and experiments.

비정현 계통 전압하에서 단상 인버터의 PLL 성능 개선 방법 (A Method to Improve the Performance of Phase-Locked Loop (PLL) for a Single-Phase Inverter Under the Non-Sinusoidal Grid Voltage Conditions)

  • Khan, Reyyan Ahmad;Ashraf, Muhammad Noman;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 추계학술대회
    • /
    • pp.7-8
    • /
    • 2017
  • The Phase-Locked Loop (PLL) is widely used in grid-tie inverter applications to achieve the synchronization between the inverter and the grid. However, its performance is deteriorated when the grid voltage is not pure sinusoidal due to the harmonics and the frequency deviation. Therefore it is important to design a high performance phase-locked loop (PLL) for the single phase inverter applications to guarantee the quality of the inverter output. In this paper a simple method to improve the performance of the PLL for the single phase inverter is proposed. The proposed PLL is able to accurately estimate the fundamental frequency component of the grid voltage even in the presence of harmonic components. In additional its transient response is fast enough to track a change in grid voltage within two cycles of the fundamental frequency. The effectiveness of the proposed PLL is confirmed through the PSIM simulation and experiments.

  • PDF

연속 자유 공간에서 가우시안 보간법을 이용한 보행자 위치 추적 (Gaussian Interpolation-Based Pedestrian Tracking in Continuous Free Spaces)

  • 김인철;최은미;오휘경
    • 정보처리학회논문지B
    • /
    • 제19B권3호
    • /
    • pp.177-182
    • /
    • 2012
  • 본 논문에서는 대규모 실내 환경에서 WiFi 모듈이 내장된 스마트폰 사용자의 위치를 추적하기 위한 효과적인 이동 모델과 관측 모델을 제시한다. 제안하는 세 가지 부속 이동 모델들은 보행자의 움직임에 대한 더 정확한 예상 확률 분포를 제공한다. 또, 가우시안 보간법 기반의 관측 모델은 훈련 데이터 의 수집이 이루어지지 않은 지역들에 대해서도 관측 우도 계산을 가능하게 한다. 파티클 필터 프레임워크 속에 이와 같은 이동 모델과 관측 모델을 결합함으로써, 본 연구의 위치 추적 알고리즘은 대규모 실내 환경들에서도 스마트폰 사용자의 위치를 정확하게 추적할 수 있다. 한 복층 건물에서 안드로이드 스마트폰으로 수행한 실험을 통해, 본 연구에서 제안한 WiFi 위치 추적 알고리즘의 성능을 확인할 수 있었다.

Effects of Gentianae Macrophyllae Radix on the functional recovery and expression of BDNF and c-Fos after sciatic crushed nerve injury in rats

  • Cho, Hyun-Chol;Song, Yun-Kyung;Lim, Hyung-Ho
    • 대한한의학회지
    • /
    • 제30권3호
    • /
    • pp.28-38
    • /
    • 2009
  • Background : Peripheral nerve injuries are a commonly encountered clinical problem and often result in a chronic pain and severe functional deficits. Objective : The aim of this study was to evaluate the effects of Gentianae Macrophyllae Radix (G. M. Radix) on the pain control and the recovery of the locomotor function that results from the sciatic crushed nerve injury in rats. Method : Using rats, we crushed their sciatic nerve, and then orally administered the aqueous extract of G. M. Radix. The effects of G. M. Radix on the recovery locomotor function were investigated by walking track analysis. The effects of G. M. Radix on pain control were investigated by brain-derived neurotrophic factor (BDNF) expression in the sciatic nerve, and c-Fos expression in the paraventricular nucleus (PVN) of the hypothalamus and in the ventrolateral periaqueductal gray (vlPAG). Result : G. M. RADIX facilitates motor function from the locomotor deficit, and thereby increased BDNF expression and suppressed painful stimuli in the PVN and vlPAG after sciatic crushed nerve injury. Conclusion : It is suggested that G. M. Radix might aid recovery locomotor function and control pain after sciatic crushed nerve injury. Further studies on identifying specific the component in G.M. Radix associated with enhanced neural activity in the peripheral nerve injury may be helpful to develop therapeutic strategies for the treatment of peripheral nerve injury.

  • PDF

Fully Analog ECG Baseline Wander Tracking and Removal Circuitry using HPF Based R-peak Detection and Quadratic Interpolation

  • Nazari, Masoud;Rajeoni, Alireza Bagheri;Lee, Kye-Shin
    • Journal of Multimedia Information System
    • /
    • 제7권3호
    • /
    • pp.231-238
    • /
    • 2020
  • This work presents a fully analog baseline wander tracking and removal circuitry using high-pass filter (HPF) based R-peak detection and quadratic interpolation that does not require digital post processing, thus suitable for compact and low power long-term ECG monitoring devices. The proposed method can effectively track and remove baseline wander in ECG waveforms corrupted by various motion artifacts, whereas minimizing the loss of essential features including the QRS-Complex. The key component for tracking the baseline wander is down sampling the moving average of the corrupted ECG waveform followed by quadratic interpolation, where the R-peak samples that distort the baseline tracking are excluded from the moving average by using a HPF based approach. The proposed circuit is designed using CMOS 0.18-㎛ technology (1.8V supply) with power consumption of 19.1 ㎼ and estimated area of 15.5 ㎟ using a 4th order HPF and quadratic interpolation. Results show SNR improvement of 10 dB after removing the baseline wander from the corrupted ECG waveform.

이동로봇의 Localization을 위한 Gryo sensor에 의한 Odometry Error 보정에 관한 연구 (Odometry error correction by Gyro sensor for mobile robot localization)

  • 박시나;노영식;최원태;홍현주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.597-599
    • /
    • 2005
  • To make the autonomous mobile robot move in the unknown space, we have to know the information of current location of the robot. So far, the location information that was obtained using Encoder always includes Dead Reckoning Error, which is accumulated continuously and gets bigger as the distance of movement increases. In this paper, we analyse the effect of the size of the two wheels of the mobile robot and the wheel track of them among the factors of Dead Reckoning Error. And after this, we compensate this Dead Reckoning Error by Kalman filter using Gyro Sensors. To accomplish this, we develop the controller to analyse the error components of Gyro Sensor and to minimize the error values. We employ the numerical approach to analyse the error components by linearizing them because each error component is nonlinear. And we compare the improved result through simulation.

  • PDF

원자력발전소 변압기 연결 선로 결상 검출 시스템 (Open-Phase Condition Detecting System for Transformer Connected Power Line in Nuclear Power Plant)

  • 하체웅;이도환
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.254-259
    • /
    • 2015
  • On January 30, 2012 an auxiliary component of Byron Unit 2 was tripped on bus under voltage. The cause of the event was the failure of the C-phase insulator track for the Unit 2 station auxiliary transformer(SAT) revenue metering transformer. In addition to this event, other events have occurred at other plants resulting in an open-phase condition.[1] Therefore, Nuclear Regulatory Commission(NRC) has requested that not only nuclear power plant(NPP) operating company but also its Design Certification(DC) applicant have to prepare open-phase detecting system in their operating plants and design document. In this paper, various open-phase conditions are simulated in NPP using Electromagnetic Transient Program(EMTP) and Atpdraw, and open-phase condition detecting system is proposed for Main Transformer(MT), Unit Auxiliary Transformer(UAT) and SAT connected power line in NPP.

철도레일 방진 체결장치의 진동 및 소음 저감 효과에 관한 실험적 연구 (Experimental Study of Vibration and Noise Reduction Effect of Railroad Vibration Isolator)

  • 이장현;김태언;이성춘;전익범
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1373-1378
    • /
    • 2000
  • Vibration caused by railroad vehicle including subway train running raises a lot of problems to the neighboring buildings. Therefore lots of methods to isolate the railway vibration have been studied and practically applied to sites. As one of them, specially designed vibration isolation device was installed in the some section of Seoul subway. This device is installed between the rail and track slab. Because the process of installation is relatively simple, this method can be applied to the existing railways in servicing. We measured the vibration and noise to check the effectiveness of this device before and after the installation. The result showed that the vibration level of the slab and platform was reduced to 7 - 10 dB. Expecially high frequency component was reduced to a large amount. From this result, we can conclude that these kind of devices are useful to the reduction of the railroad vibration, expecially the high frequency vibration which can cause structure born noise.

  • PDF