• Title/Summary/Keyword: Tracer-test

Search Result 183, Processing Time 0.03 seconds

A Case Study on the Development of Learning-Instruction for Computer Network Courses and CCNA Certification (컴퓨터 네트워크 교과목 수업과 CCNA 인증을 위한 교수학습 개발에 관한 사례 연구)

  • Kim, No-Whan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.11
    • /
    • pp.229-240
    • /
    • 2013
  • This study critically review the textbooks and the syllabus of computer network courses currently used at universities, and the specifications of the certifications concerned to provide the students with the competitive and optimized course contents. Considering the vitality of the practicum in the computer network courses, we also suggest a new learning-instruction case study that focuses on the practice by analyzing the computer network practice test simulators which are certified nationally and the internationally. The proposed learning-instruction case study for computer network courses includes the weekly core lessons and contents, study goals and key points, the practice theme, handy tools based on two track of lecture and practice. Therefore it is expected to be a quite resourceful and practical teaching plan for the teacher, and a highly achievement of learning outcomes through motivation which can facilitate CCNA certification enrolling in the field of network aspect for the learner.

Effect of Different Exercise Intensity on Blood Melatonin Density in Sleep Disordered Rats (운동 강도가 수면장애 모델 쥐의 혈 중 멜라토닌 농도에 미치는 영향)

  • Kim, Hee-Jung;Kim, Dong-Hyun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.1
    • /
    • pp.45-53
    • /
    • 2014
  • PURPOSE: In this study, we tried to find out what kind of exercise was more effective in sleep disorder by comparing melatonin in blood after applying low intensity with high intensity exercise to sleep disordered rats induced by experiment. METHODS: We used male Sprague-Dawley rats which were 8weeks old and weighted 300g. They were supplied with water and food without any restriction. We kept the room temperature at $25^{\circ}C$ and controld the length of day and night in 12 hours blocks, respectively. We divided the rats 60 into 2 groups. To one group we applied low intensity exercise, and to the other we applied high intensity exercise for 15minutes per day over a period of 4 weeks. We extracted the blood from abdominal aorta before, after exercise, moved into EDTA tube, performed centrifugation. We decanted the serum $200{\mu}l$ from the blood into microcentrifuge tube by samples and moved into polypropylene culture tubes with micro pipette. We split enzyme solution $50{\mu}l$ into the tubes with melatonin direct kits and make them react at $37^{\circ}C$ for 2 hours. We split assay buffer $50{\mu}l$ into each tube and mixed melatonin tracer $50{\mu}l$ and melatonin antiserum $50{\mu}l$, respectively. After we made them react in room temperature, we decanted the superficial layer with a centrifuge and measured the activity for 1 minute by competitive method with ${\gamma}$-counter equipment. We draw a standard curve through logit-log graph with CPM(counts per minute) and counted the melatonin by B/B0. We conducted independent t-test to examine the homogeneous of melatonin value of before low-intensity and high-intensity exercise. We performed paired t-test to compare before and after low-intensity and high-intensity exercise, respectively. We carried out independent t-test to compare melatonin value after low-intensity and high-intensity exercise. Significance level was .05. RESULTS: The results were as follows; firstly melatonin was more increased in the group who was exposed to high intensity exercise when we compared before to after high and low intensity exercise, respectively. Secondly, high intensity exercise was more effective than low intensity exercise when we compared the two. CONCLUSION: In conclusion, secretion of melatonin which is the material of sleep improvement could be promoted by high intensity exercise. Low intensity exercise acted as a stress rather than improving sleep and had a negative effect on the secretion of melatonin because the melatonin was affected by stress.

Retardation Effect and Mobility of a Heavy Metal in a Sandy Soil (사질토양에서의 중금속의 지연효과와 이동성)

  • Kim, Dong-Ju;Baek, Doo-Sung
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.5 no.3
    • /
    • pp.155-161
    • /
    • 1998
  • Retardation effect of heavy metals in soils caused by adsorption onto the surfaces of solids particles is well known phenomenon. In this study, we investigated the retardation effect on the mobility of a Zn in a sandy soil by conducting batch and column tests. The column test consisted of monitoring the concentrations of effluent versus time known as a breakthrough curve (BTC). We used NaCl and ZnCl$_2$ solutions with the concentration of 10 g/L as a tracer, and injected them respectively into the inlet boundary of the soil sample as a square pulse type, and monitored the effluent concentrations at the exit boundary under a steady state condition using an EC-meter and ICP-AES. The batch test was conducted based on the standard procedure of equilibrating fine fractions collected from the soil with various initial ZnCl$_2$ concentrations, and analysis of Zn ions in the equilibrated solutions using ICP-AES. The results of column test showed that i) the peak concentration of ZnCl$_2$analyzed by ICP was far less than that of either NaCl or bulk electrical conductivity and ⅱ) travel times of peak concentrations for two tracers were more less identical. The relatively low concentration of Zn can be explained by ion exchange between Zn and other cations, and possible precipitation of Zn in the form of Zn(OH)$_2$due to high pH range (7.0∼7.9) of the effluent. The identical result of travel times of peak concentrations indicates that the retardation effect is not present in the soil. The only way to describe the prominent decrease of Zn ion was to introduce decay or sink coefficient in the CDE model to account for irreversible decrease of Zn ions in the aqueous phase.

  • PDF

A Study on the Optimal Image Acquisition Time of 18F- Flutemetamol using List Mode (LIST mode를 이용한 18F-Flutemetamol 의 최적 영상획득 시간에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.891-897
    • /
    • 2021
  • With the development of Amyloid PET Tracer, the accuracy of Alzheimer's diagnosis can be improved through the identification of beta-amyloid neurites. However, the long image acquisition time of 20 minutes can be difficult for the patient. PET/CT scans are sensitive to patient movement and may partially affect test results. In this study, we studied the proper image acquisition time without affecting the quantitative evaluation of the image through the list mode acquisition method according to the time of the distribution of radioactive drugs in the body. The list mode includes information about time compared to the existing frame mode, and it is easy to analyze data because it can reconstruct images about the time that researchers want. The research method obtained a reconstructed image by time using a list mode of 5min frame/bed, 10min frame/bed, 15min frame/bed, and 20min frame/bed to compare the difference between signal-to-pons take ratio (SNR) and lesion-to-pons uptake ratio (LPR) and the difference in reading time to obtain an appropriate image. As a result of quantitative analysis, when measuring in list mode, SUVmean values decreased in 6 regions of interest as the image acquisition time increased, but showed the largest difference in 5 min/bed images, followed by 10 min/bed and 15 min/bed. As a result, the difference in SUVmean values decreased. Therefore, it was found that SUVmean values at 15 min/bed did not differ enough to not affect image evaluation. There was no difference in LPR values. As a result of the qualitative analysis, there was no change in the reading findings according to the PET image acquisition time and there was no significant difference in the qualitative analysis score of the image reconstruction according to time. As a result of the study, there is no significant difference between 15 min/bed and 20 min/bed images during the 18F-flutemetamol PET/CT test, so it can be said that it is clinically useful to reduce the image acquisition time selectively using 15 min/bed via list mode depending on the patient's condition.

Field Tests for Assessing the Bioremediation Feasibility of a Trichloroethylene-Contaminated Aquifer (관측정 자연표류 실험을 통한 트리클로로에틸렌(Trichloroethylene) 오염 지하수의 생물학적 복원 타당성 연구)

  • Kim Young;Kim Jin-Wook;Ha Chul-Yoon;Kim Nam-Hee;Hong Kwang-Pyo;Kwon Soo-Yul;Ahn Young-Ho;Ha Joon-Su;Park Hoo-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.3
    • /
    • pp.38-45
    • /
    • 2005
  • The feasibility of stimulating in situ aerobic cometabolic activity of indigenous microorganisms was investigated in a trichloroethylene (TCE)-contaminated aquifer. A series of single-well natural drift tests (SWNDTs) was conducted by injecting site groundwater amended with a bromide tracer and combinations of toluene, oxygen, nitrate, ethylene and TCE into an existing monitoring well and by sampling the same well over time. Three field tests, Push-pull Transport Test, Drift Biostimulation Test, and Drift Surrogate Activity Test, were performed in sequence. Initial rate of toluene degradation was much faster than the rate of bromide dilution resulting from natural groundwater drift, indicating stimulation of indigenous toluene-oxidizing microorganisms. Transformation of ethylene, a surrogate probing overall activity of TCE transformation, was also observed, and its transformation results in the production of ethylene oxide, suggesting that some tolueneoxidizing microorganisms stimulated may express a orthomonooxygenase enzyme. Also in situ transformation of TCE was confirmed by greater retardation of TCE than bromide after the stimulation of toluene-oxidizing microorganisms. These results indicate that, in this environment, toluene and oxygen additions stimulated the growth and aerobic cometabolic activity of indigenous microorganisms expressing orthomonooxygenase enzymes. The simple, low-cost field test method presented in this study provides an effective method for conducting rapid field assessments and pilot testing of aerobic cometabolism, which has previously hindered application of this technology to groundwater remediation.

Efficacy of I-123/I-131 Metaiodobenzylguanidine Scan as A Single Initial Diagnostic Modality in Pheochromocytoma: Comparison with Biochemical Test and Anatomic Imaging (갈색세포종의 초기 진단에서 I-123/I-131 Metaiodobenzylguanidine 스캔의 단일 검사로써의 진단 성능: 생화학적 검사, 해부학적 영상과 비교)

  • Moon, Eun-Ha;Lim, Seok-Tae;Jeong, Young-Jin;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.436-442
    • /
    • 2009
  • Purpose: We underwent this study to evaluate the diagnostic potential of I-123/I-131 metaiodobenzylguanidine (MIBG) scintigraphy alone in the initial diagnosis of pheochromocytoma, compared with biochemical test and anatomic imaging. Materials & Methods: Twenty two patients (M:F=13:9, Age: $44.3{\pm}\;19.3$ years) having the clinical evaluation due to suspicious pheochromocytoma received the biochemical test, anatomic imaging modality (CT and/or MRI) and I-123/I-131 MIBG scan for diagnosis of pheochromocytoma, prior to histopathological confirmation. MIBG scans were independently reviewed by 2 nuclear medicine physicians. Results: All patients were confirmed histopathologically by operation or biopsy (incisional or excisonal). In comparison of final diagnosis and findings of each diagnostic modality, the sensitivities of the biochemical test, anatomic imaging, and MIBG scan were 88.9%, 55.6%, and 88.9%, respectively. And the specificities of the biochemical test, anatomic imaging, and MIBG scan also were 69.2%, 69.2%, and 92.3%, respectively. MIBG scan showed one false positive (neuroblastoma) and one false negative finding. There was one patient with positive MIBG scan and negative findings of the biochemical test, anatomic imaging. Conclusion: Our data suggest that I-123/I-131 MIBG scan has higher sensitivity, specificity, positive predictive value, negative predictive value and accuracy than those of biochemical test and anatomic imaging. Thus, we expect that MIBG scan is e tectively used for initial diagnosis of pheochromocytoma alone as well as biochemical test and anatomic imaging.

A Suggestion for Counting Efficiency Management of the Automation Instrument (자동화장비 계측효율 관리적 측정방법 제안)

  • Park, Jun Mo;Kim, Han Chul;Choi, Seung Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.105-111
    • /
    • 2018
  • Purpose Quality control of instrument takes up a large part in the Radioimmunoassays. The gamma-ray instrument, which is one of the important instruments in the laboratory, observes the condition and performance of instrument and performs quality control of the instrument by measuring the Normalization, Calibration, Background and etc. However, there are some automation instruments which can't measure the counting efficiency of gamma-ray meters, resulting in insufficient management in terms of performance evaluation of gamma-ray meters. Therefore, the purpose of this paper is to manage the quality control continuously and regularly by suggesting how to measure the counting efficiency of gamma-ray instruments. Materials and Methods In case of a comparative measurement method to a gamma-ray instrument dedicated to nuclear medical examination, the CPM and counting efficiency can be obtained after the measurement of normalization by inserting the I-125 $200{\mu}L$(CPM 50,000~500,000) into the test tube. With this CPM and counting efficiency values, it's possible to calculate the measurement of the DPM value and count the CPM from the automation instrument from the same source, and enter the DPM to calculate the counting efficiency using a comparative measurement method. Another method is to calculate the counting efficiency by estimating the half life using the radiation source information of the tracer in B test reagents of company A. Results According to the calculation formula using the DPM obtained by counting the normalization of gamma-ray meters, the detection efficiency was 75.16% for Detector 1, 76.88% for Detector 2, 77.13% for Detector 3, 75.36% for Detector 4 and 73.2% for Detector 5 respectively. Using another calculation formula estimated from the shelf life, the data of the detection efficiency from Detector 1 to Detector 5 were 74.9%, 75.1%, 76.5%, 74.9% and 73.2% respectively. Conclusion Although the accuracy of counting efficiencies of both methods are insufficient, this is considered to be useful for ongoing management of quality control if counting efficiency is managed after setting the acceptable ranges. For example, if the measurement efficiency is set to 70% or higher, the allowed %difference between measurements is within 3% and the %difference with the detector wall is set within 5%.

Evaluation of Ventilation Performance of a Residential Unit for Different Sampling Points through Actual Field Tests (실증실험을 통한 측정 위치에 따른 주거공간 환기성능 평가)

  • Kwag, Byung Chang;Lee, Soo Man;Kim, Gil Tae;Kim, Jong Yeob
    • Land and Housing Review
    • /
    • v.13 no.3
    • /
    • pp.93-106
    • /
    • 2022
  • Ventilation plays an important role in controlling indoor air quality. Due to the recent spread of infectious diseases such as COVID-19 and with people spending more time indoors, there's been increased attention on the importance of ventilation performance. In many countries, ventilation is regulated by airflow rates and the number of air changes per hour (ACH). However, airflow rates and ACH alone do not provide an accurate account of actual indoor pollutant removal and ventilation uniformity in a space. This study looked into the ventilation performance of an actual residential unit using several sampling points instead of basing it off of airflow and air change rates. Literature review was used to derive relevant influencing factors and the tracer gas dilution method was used for the field test. The study measured air velocity, age of air, and ventilation efficiency at several locations and compared them to the average value at the center of the test space to determine the differences in ventilation performance at the selected measurement points. The study showed that different sampling locations resulted in different ventilation values. Findings of this study will be used to develop an experimental procedure for evaluating indoor ventilation performance of actual residential spaces.

Explosion Likelihood Investigation of Facility Using CVD Equipment Using SEMI S6 (SEMI S6를 적용한 CVD 설비의 폭발분위기 조성 가능성 분석)

  • Mi Jeong Lee;Dae Won Seo;Seong Hee Lee;Dong Geon Lee;Se Jong Bae;Jong-Bae Baek
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.62-67
    • /
    • 2023
  • Due to the prolonged impact of COVID-19, the demand for Information Technology (IT) products is increasing, and their production facilities are expanded. Consequently, the use of harmful and dangerous chemicals are increased, the risk of fire(s) and explosion(s) is also elevated. In order to mitigate these risks, the government sets standards, such as KS C IEC 60079-10-1, and manages explosion-prone hazardous facilities where flammable substances are manufactured, used, and handled. However, using the standards of KS, it is difficult to predict the actual possibility of an explosion in a facility, because ventilation (an important factor) is not considered when setting up a hazardous work environment. In this study, the SEMI S6, Tracer Gas Test was applied to the chemical vapor deposition (CVD) facility, a major part of the display industry, to evaluate ventilation performance and to confirm the possibility of creating a less explosive environment. Based on the results, it was confirmed that the ventilation performance in the assumed scenarios met the standards stipulated in SEMI S6, along with supporting the possibility of creating a less explosive working condition. Therefore, it is recommended to use the prediction tool using engineering techniques, as well as KS standards, in such hazardous environments to prevent accidents and/or reduce economic burden following accidents.

Role of Rest Redistribution Imaging in T1-201 Reinjection Imaging Technique (탈륨 재주사영상법에서 휴식기재분포영상의 의의)

  • Bom, Hee-Seung;Song, Ho-Chun;Kim, Ji-Yeul;Jeong, Myung-Ho;Kang, Jung-Chaee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.191-194
    • /
    • 1993
  • Apparent washout of T1-201 may occur between redistribution and reinjection images. To examine the frequency of it, we prospectively compared 4-hour redistribution and reinjection images in 63 consequent patients. All patients underwent pharmacological stress test using 0.56 mg/kg dipyridamole. Immediately after the 4-hour redistribution images, 1 mCi T1-201 was injected at rest, and images were reacquired 10 minutes after reinjection. The stress, redistribution, and reinjection images were then analyzed semiquantitatively (0=no uptake, 1=faint uptake, 2=mildly diminished uptake, 3=normal uptake). Of the 100 abnormal myocardial regions on the stress images, 54 showed either complete or partial reversibility on 4-hour redistribution images. After reinjection 11(21.2%) of these regions demonstrated apparent T1-201 washout due to low differential uptake of the tracer. Such lesions would appear irreversible if redistribution imaging is not performed before reinjection. Thus 4-hour redistribution imaging should be performed for assessment of myocardial ischemia and viability.

  • PDF